ElectricTM is a trademark of Static Free Software .
Permission is granted to make and distribute verbatim copies of this manual provided the copyright notice and this permission notice are preserved on all copies.
Permission is granted to copy and distribute modified versions of this manual under the conditions for verbatim copying, provided also that they are labeled prominently as modified versions, that the authors' names and title from this version are unchanged (though subtitles and additional authors' names may be added), and that the entire resulting derived work is distributed under the terms of a permission notice identical to this one.
Permission is granted to copy and distribute translations of this manual into another language, under the above conditions for modified versions.
![]() |
1-1: Welcome |
![]() |
A state-of-the-art computer-aided design system for VLSI circuit design.
Electric designs MOS and bipolar integrated circuits, printed-circuit-boards, or any type of circuit you choose. It has many editing styles including layout, schematics, artwork, and architectural specifications.
A large set of tools is available including design-rule checkers, simulators, routers, layout generators, and more.
Electric interfaces to most popular CAD specifications including VHDL, CIF and GDS II.
The most valuable aspect of Electric is its layout-constraint system, which enables top-down design by enforcing consistency of connections.
This manual explains the concepts and commands necessary to use Electric. It begins with essential features and builds on them to explain all aspects of the system. As with any computer system manual, the reader is encouraged to have a machine handy and to try out each operation.
![]() |
1-2: About Electric |
![]() |
This manual is available while running Electric. Use the User's Manual... command (in menu Help) to see this manual (you may already be doing that).
While inside of the manual, click "Menu Help" to get help with Electric's pulldown menus. It displays a pulldown menu inside of the manual page which mimics the real pulldown menu. Select any command from this new menu to get help for the real pulldown menu entry.
![]() |
1-3: Requirements |
![]() |
Electric requires Java version 1.3 or later. It has been tested with Java version 1.5.
If you extract the source code from the ".jar" file and wish to build Electric, note that there are some Macintosh OS/X issues to consider.
One problem with Java is that the Java Virtual Machine has a memory limit. This limit prevents programs from growing too large, and speeds up garbage collection. However, it prevents large circuits from being edited. If Electric runs out of memory, you can request that more be used. To do this, use "General" preferences (in menu File / Preferences..., "General" section, "General" tab). At the bottom of the dialog is a memory limit field. You will have to quit Electric and restart it for the new memory limit to take effect.
![]() |
1-4: Setup |
![]() |
java -jar electric.jar
java -jar electric.jar
java -jar electric.jar
If the above form of the command does not work, try this alternate form:
java -classpath electric.jar com.sun.electric.Launcher
There are a number of options that can be given at the end of the command line:
-mdi
force a multiple document interface style
(where Electric is one big window with smaller edit windows in it).-sdi
force a single document interface style
(where each Electric window is separate).-s <script>
run the <script> file through the Bean shell.-batch
run in batch mode (no windows or other user iterface are shown).-version
provides full version information including build date.-v
provides brief version information.-help
prints a list of available command options.![]() |
1-5: Plug-Ins |
![]() |
To attach a plugin, it must be invoked from the command line by adding it to the classpath. For example, to add the beanshell (a file named "bsh-2.0b1.jar"), type:
java -classpath electric.jar:bsh-2.0b1.jar com.sun.electric.Launcher
On Windows, you must use the ";" to separate jar files, and you might also have to quote the collection since ";" separates commands:
java -classpath "electric.jar;bsh-2.0b1.jar" com.sun.electric.Launcher
Note that you must explicitly mention the main Electric class (com.sun.electric.Launcher) when using plug-ins since all of the jar files are grouped together as the "classpath".
![]() |
1-6: Fundamental Concepts |
![]() |
ELECTRIC IS DIFFERENT because it uses connectivity for all design, even IC layout. This means that you place components (MOS transistors, contacts, etc.) and draw wires (metal-2, polysilicon, etc.) to connect them. The screen shows the true geometry, but it knows the connectivity too.
The advantages of connectivity-based IC layout are many:
The disadvantages of connectivity-based IC layout are also known:
The way that Electric handles all types of circuit design is by viewing it as a collection of nodes and arcs, woven into a network. The nodes are electrical components such as transistors, contacts, and logic gates. Arcs are simply wires that connect two components. Ports are the connection sites on nodes where the wires connect. | ![]() |
In the above example, the transistor node has three pieces of geometry on different layers: polysilicon, active, and well. This node can be scaled, rotated, and otherwise manipulated without concern for specific layer sizes. This is because rules for drawing the node have been coded in a technology , which describes nodes and arcs in terms of specific layers.
Because Electric uses nodes and arcs for design, it is important that they be used to make all of the relevant connections. Although layout may appear to be connected when two components touch, a wire must still be used to indicate the connectivity to Electric. This requires a bit more effort when designing a circuit, but that effort is paid back in the many ways that Electric understands your circuit.
Besides creating meaningful electrical networks, arcs which form wires in Electric can also hold constraints. A constraint helps to control geometric changes, for example, the rigid constraint holds two components in a fixed configuration while the rest of the circuit stretches. These constraints propagate through the circuit, even across hierarchical levels of design, so that very complex circuits can be intelligently manipulated.
A cell is a collection of these nodes and arcs, forming a circuit description. There can be different views of a cell, such as the schematic, layout, icon, etc. Also, each view of a cell can have different versions, forming a history of design. Multiple views and versions of a cell are organized into Cell groups.
For example, a clock cell may consist of a schematic view and a layout view. The schematic view may have two versions: 1 (older) and 2 (newer). In such a situation, the clock cell group contains 3 cells: the layout view called "clock{lay}", the current schematic view called "clock{sch}", and the older schematic view called "clock;1{sch}".
Hierarchy is implemented by placing instances of one cell into another. When this is done, the cell that is placed is considered to be lower in the hierarchy, and the cell where it is placed is higher. Therefore, the notion of going down the hierarchy implies moving into a cell instance, and the notion of going up the hierarchy implies popping out to where the cell is placed. Note that cell instances are actually nodes, just like the primitive transistors and gates. By defining exports inside of a cell, these become the connection sites, or ports, on instances of that cell.
A collection of cells forms a library, and is treated on disk as a single file. Because the entire library is handled as a single entity, it can contain a complete hierarchy of cells. Any cell in the library can contain instances of other cells. A complete circuit can be stored in a single library, or it can be broken up into multiple libraries.
![]() |
1-7: The Display |
![]() |
The editing window is the largest window that initially says "No cell in this window" (this indicates that no circuit is being displayed in that window). You can create multiple editing windows to see different parts of the design.
The left side of the edit window is the side bar that has 3 tabbed sections,
the components menu, the cell explorer, and the layers.
The cell explorer lets you examine the hierarchy, system activity, and error messages (see Section 4-8 for more). The components menu shows a list of nodes (blue border) and arcs (red border) that can be used in design. The arrangement of the entries in the components menu varies with the different technologies. For MOS technologies, see Section 7-4-2, for schematics, see Section 7-5-1, and for artwork, see Section 7-6-1. The top three entries in the components menu let you place pure-layer nodes (see Section 6-10-1), miscellaneous objects (see Section 7-6-3) and instances of cells (see Section 3-3). The layers tab lets you control which parts of the display are visible. See Section 4-5 for more on layer visibility. Below the edit window is the messages window, which is used for all textual communication. Above the edit windows is a pulldown menu along the top with command options. On some operating systems, the pulldown menu is part of the edit window, and on others it is separate. Below the pulldown menu is a tool bar which has buttons for common functions. Finally, the status area gives useful information about the design state. It appears along the bottom of the editing window or (in this example) at the bottom of the screen. The status area shows cursor coordinates, and can show global coordinates when traversing the hierarchy. To control the display of global coordinate values, use the "General" preferences (in menu File / Preferences..., "General" section, "General" tab), and change the "Show hierarchical cursor coordinates in status bar" checkbox. | ![]() |
![]() |
1-8: The Mouse |
![]() |
Modifier | Button | Action |
---|---|---|
Left Mouse Click | Select | |
Left Mouse Drag | Move selected objects | |
Left Mouse Double Click | Get Info | |
CTRL | Left Mouse Click | Cycle through selected objects |
SHIFT | Left Mouse Click | Invert selection |
CTRL + SHIFT | Left Mouse Click | Cycle through objects to Invert |
Right Mouse Click | Draw or Connect Wire | |
SHIFT | Right Mouse Click | Zoom Out |
SHIFT | Right Mouse Drag | Zoom In |
CTRL + SHIFT | Right Mouse Drag | Draw Box |
Wheel Mouse Up/Down | Scroll Up/Down | |
SHIFT | Wheel Mouse Up/Down | Scroll Right/Left |
By combining special keystrokes with the mouse functions, advanced layout operations can be done:
![]() |
1-9: The Keyboard |
![]() |
Many common commands can be invoked by typing "quick keys" for them.
These quick keys are shown in the pulldown menus next to the item.
For example, the New Cell... command (in menu Cell) has the quick key "Control-N".
On the Macintosh, the menu shows "![]() | ![]() |
To change the bindings of quick keys, use the "Key Bindings" preferences (in menu File / Preferences..., "Tools" section, "Key Bindings" tab). The dialog shows the hierarchical structure of the pulldown menus on the top, and lets you add or remove key bindings in the bottom area.
You can remove a quick key binding with the "Remove" button, and you can add a quick key binding with the "Add" button. The "Reset" button restores default quick key bindings. Change key bindings with caution, because it customizes your user interface, making it more difficult for other users to work at your station.
You can get to EVERY menu command with key sequences. The keys to use are underlined in the menus. For example, the File menu has the "F" underlined, and the Print... command of that menu has the "P" underlined. This means that you can hold the Alt key and type "FP" to issue the print command.
![]() |
1-10-1: IC Layout Example: Make a Cell |
![]() |
![]() | Before you can place any IC layout, the editing window must have a cell in it. Use the New Cell... command (in menu Cell). This will show a dialog that lets you type a new cell name. Type the name ("MyCircuit" is used here) and click OK. The editing window will no longer have the "No cell in this window" message, and circuitry may now be created. |
After creating a cell, look at the cell explorer (in the status bar on the left side of the edit window). Under the "LIBRARIES" icon, you will see the list of libraries (currently only one called "noname"). If you open that library's icon, you will see the cells in the library (currently only "MyCircuit"). | ![]() |
In this example, the top node is called Metal-1-Polysilicon-1-Con (a contact between metal layer 1 and polysilicon layer 1, found in the fifth entry from the bottom in the right column of the component menu). The node on the bottom is called N-Transistor (lower-right entry of the component menu). Both of these nodes are from the MOSIS CMOS technology (which is listed as "mocmos" in the status area). | ![]() |
![]() | A highlighted node has two selected areas: the node and a port on that node. Note that the transistor is highlighted in the previous example, and the contact is highlighted in the example here. The larger selected area covers the node, and it surrounds the "important" part (for example, on the Transistor, it covers only the overlap area, excluding the tabs of active and gate on the four sides). The smaller selected area is the currently highlighted port (there are four possible ports on the transistor, but only one on the contact). |
To highlight a node, use the left button. The node, and the closest port to the cursor, will be selected. After highlighting, you can hold the mouse button down and drag the highlighted object to a new location. If nothing is under the cursor when the selection button is pushed, you may drag the cursor while the button remains down to define an area in which all objects will be selected.
Another way to affect what is highlighted is to use the shift-left button. This button causes object highlighting to be reversed (highlighted objects become unhighlighted and unhighlighted objects are highlighted).
The shape of the highlighted port is important. Ports are the sites of arc connections, so the end point of the arc must fall inside this port area. Ports may be rectangles, lines, single points (displayed as a "+"), or any arbitrary shape. For example, when the active tabs of a transistor are highlighted, the port is shown as a line.
To wire a component, select it, move the cursor away from the component, and use the right button. A wire will be created that runs from the component to the location of the cursor. Note that the wire is a fixed-angle wire which means that it will be drawn along a horizontal or vertical path from the originating node. | ![]() |
To see where the wire will end, click but do not release the button and drag the outline of the wire's terminating node (a pin) until it is in the proper location. It is highly recommended that you do all wiring operations this way, because wiring is quite complex and can follow many different paths.
Once a wire has been created, the other end is highlighted (see above). This is the highlighting of a pin node that was created to hold the other end of the arc. Because it is a node, the right button can be used again to continue the wire to a new location. If, during wiring, the cursor is dragged on top of an existing component, the wire will attach to that component.
To remove wires or components, you can issue the Undo command (in menu Edit) to remove the last created object. Alternatively, you can select the component and use the Erase command (in menu Edit).
Select a wire and issue the Rigid command (in menu Edit / Arc). The letters change to "R" on the arc and the wire no longer stretches when nodes move. Find another arc and issue the Not Fixed-angle command. Now observe the effects of an unconstrained arc as its neighboring nodes move. These arc constraints can be reversed with the Rigid and Fixed-angle commands. See Section 5-2-1 for more on these constraints.
Electric supports hierarchy by allowing you to place instances of another cell. These instances are nodes, just like the simpler ones in the component menu. To see hierarchy in action, create a new cell with the New Cell... command (in menu Cell). Make sure the "Make new window" option is checked in the dialog. Then type the new cell name ("Higher" is used in the example here). | ![]() |
A new (empty) cell will appear in a separate window. Try creating a few simple nodes in this new window (place a contact or two).
![]() | Now place an instance of the other cell by using the Place Cell Instance... command (in menu Cell). You can also click the "Cell" entry in the component menu. You will be given a list of cells to create: select the one that is in the OTHER window (the one called "MyCircuit" in this example). Then click in the newer cell to create the instance. |
The box that appears is a node in the same sense as the contacts and transistors: it can be moved, wired, and so on. In addition, because the node contains subcomponents, you can see its contents by selecting it and using the One Level Down command (in menu Cell / Expand Cell Instances, or click on the opened-eye button in the tool bar). Note that if the objects in a cell no longer fit in the display window, use the Fill Display command (in menu Window). | ![]() |
![]() | This is done by creating exports inside the cell definition. Move the cursor to the window with the lower-level cell ("MyCircuit") and select the contact node. Then issue the Create Export... command (in menu Export). You will be prompted for an export name and its characteristic (the characteristics can be ignored for now). |
![]() |
This takes the port on the contact node and exports it to the outside world.
Its name will be visible on the unexpanded instance node in the higher-level cell.
You can now connect wires to that node in just the same way as you wired the contact. | ![]() |
![]() |
1-11-1: Schematics Example: Make a Cell |
![]() |
![]() | Before you can place any schematics, the editing window must have a cell in it. Use the New Cell... command (in menu Cell). Type the name ("MyCircuit" is used here) and select the "schematic" view. |
The editing window will no longer have the "No cell in this window" message, and circuitry may now be created. Note that the component menu on the left will change to show schematics primitives. Also, the Schematic technology is now listed in the status area at the bottom of the screen.
After creating a cell, look at the cell explorer (in the status bar on the left side of the edit window). In the "LIBRARIES" icon, you will see the list of libraries (currently only one called "noname"). If you open that library's icon, you will see the cells in the library (currently only "MyCircuit"). | ![]() |
Schematic nodes are placed by selecting them from the side bar's components menu (on the left), and then wiring them together. This example shows two nodes that have been created. This was done by clicking on the appropriate component menu entry, and then clicking again in the editing window to place that node. | ![]() |
After clicking on the component menu entry, the cursor changes to a pointing hand to indicate that you must select a location for the node. When placing the node, if you press the button and do not release it, you will see an outline of the new node, which you can drag to its proper location before releasing the button.
In this example, the top node is called a Buffer (found on the right side of the component menu in the third entry from the top). The node on the bottom is called an And (top entry on the right).
![]() | A highlighted node has two selected parts: the node and a port on that node. Note that the And is highlighted in the previous example, and the Buffer is highlighted in the example here. The little "+" sign is the currently highlighted port (there are two possible ports on these nodes, on the input and the output). |
To highlight a node, use the left button. The node, and the closest port to the cursor, will be selected. After highlighting, you can hold the mouse button down and drag the highlighted object to a new location. If nothing is under the cursor when the selection button is pushed, you may drag the cursor while the button remains down to define an area in which all objects will be selected.
Another way to affect what is highlighted is to use the shift-left button. This button causes object highlighting to be reversed (highlighted objects become unhighlighted and unhighlighted objects are highlighted).
The shape of the highlighted port is important. Ports are the sites of arc connections, so the end point of the arc must fall inside this port area. Ports may be rectangles, lines, single points (displayed as a "+"), or any arbitrary shape. For example, the entire left side of the And gate is the input port and so its highlighting is a line.
To wire a component, select it, move the cursor away from the component, and use the right button. If you click the right button and hold it without releasing, then you can move around and see where the wire will go when you do release. | ![]() |
A wire will be created that runs from the component to the location of the cursor. Note that the wire is a fixed-angle wire which means that it will be drawn along a horizontal, vertical, or 45-degree path from the originating node. To see where the wire will end, click but do not release the button and drag the outline of the wire's terminating node (a pin) until it is in the proper location. It is highly recommended that you do all wiring operations this way, because wiring is quite complex and can follow many different paths.
Once a wire has been created, the other end is highlighted (see above). This is the highlighting of a pin node that was created to hold the other end of the arc. Because it is a node, the right button can be used again to continue the wire to a new location. If, while wiring, the dragged location is over an existing component, the wire will attach to that component.
To remove wires or nodes, you can issue the Undo command (in menu Edit) to remove the last created object. Alternatively, you can select the component and use the Erase command (in menu Edit).
To negate an input or output of a digital gate, select the port or the arc and use the Toggle Port Negation command (in menu Edit / Technology Specific ). With this facility, you can construct arbitrary gate configurations. | ![]() |
Select a wire and issue the Rigid command (in menu Edit / Arc). The letter changes to "R" on the arc and the wire no longer stretches when components move. Find another arc and issue the Not Fixed-angle command. Now observe the effects of an unconstrained arc as its neighboring nodes move. These arc constraints can be reversed with the Rigid and Fixed-angle commands. See Section 5-2-1 for more on these constraints.
![]() | To define connection points for a schematic, you must create exports on the schematic. To see an example of this, select the output port of the Buffer node and issue the Create Export... command (in menu Export). You will be prompted for an export name and its characteristics (set the characteristics to "output"). |
The output port on the buffer node is now exported to the outside world. Run a wire from the input side of the And node and export the pin at the end of the wire. Your circuit should look like this. | ![]() |
![]() | You can now make an icon for this circuit by using the Make Icon command (in menu View). The icon will be placed in your circuit (you may have to move it away from the rest of the circuitry). The result will look like this. |
To test this icon in a circuit, create a new cell in which to place instances of the icon.
Use the New Cell... command (in menu Cell).
Type the new cell name ("Higher" is used in the example here) and make sure its view is "schematic".
A new (empty) cell will appear in a separate window. Try creating a few simple nodes in this new window (place a gate or two). | ![]() |
![]() | Now place an instance of the other cell by using the Place Cell Instance... command (in menu Cell). You can also click the "Cell" entry in the component menu. You will be given a list of cells to create: select the one that is in the OTHER window (the one called "MyCircuit{ic}" in this example). Then click in the newer cell to create the instance. |
The icon that appears is a node in the same sense as the Buffer and And gate: it can be moved, wired, and so on. In addition, because the node contains subcomponents, you can see its contents by selecting it and using the Down Hierarchy command (in menu Cell). Note that if the objects in a cell no longer fit in the display window, use the Fill Window command (in menu Window). | ![]() |
![]() |
2-1-1: Selecting Nodes and Arcs |
![]() |
Selection (and movement, wiring, and zooming) are done in "selection" mode, which is the default mode. This mode is indicated by having the "selection" icon highlighted in the tool bar. | ![]() |
Selection is done with clicks of the left button. Individual nodes and arcs are selected by clicking over them. You can tell in advance what will be selected by the button click, because the next object to be selected is shown in blue. This advance selection is called "mouse-over highlighting" and can be disabled (see section 2-1-4). Once selected, objects are highlighted on the screen. If you use the shift-left button, unhighlighted nodes and arcs are added to the selection, but objects that are already highlighted become deselected.
There are often multiple objects under the cursor (for example, in the area where an arc overlaps a node). To get the object you want, hold the control key while clicking. The control-left button cycles through all objects under the cursor.
The notion of toggling selection (shift-left) and cycling through what is under the cursor (control-left) can be combined. If there are multiple objects under the cursor, and you are trying to toggle the selection, use the control-shift-left button to cycle through them .
To select an object by its name, use the Select Object... command (in menu Edit / Selection).
The resulting dialog lets you select nodes, arcs, exports, or networks in the cell.
To select everything in the cell, use the Select All command (in menu Edit / Selection). To deselect everything, use Select Nothing. To select everything in the cell that is the same as the currently selected objects, use the Select All Like This command (in menu Edit / Selection). The Deselect All Arcs command deselects all selected arcs. This is useful when you wish to select a set of nodes, but you have selected the entire area, including nodes and arcs. | ![]() |
![]() | Highlighted objects have a box drawn around them. In some cases, the object extends beyond the box, but the box encloses the essential part of the object. For example, MOS transistors are highlighted where the two materials cross, even though the materials extend on all four sides. Also, CMOS active arcs have implants that surround them, but the highlight covers only the central active part. |
Besides the basic box, there will be other things drawn when an object is highlighted. Highlighted arcs have their constraint characteristics displayed. The example above shows an arc that is both fixed-angle ("F") and slidable ("S"). The letter "R" is used for rigid arcs, and an "X" appears when none of these constraints apply. See Section 5-1 for more information on arc constraints.
When nodes are selected, a port is also highlighted. The port that is highlighted is the one closest to the cursor when the node is selected. If the port is a single point, you see a "+" at the port. If the port is larger than a single point, it is shown as a line or rectangle.
Highlighted nodes will also show the entire network that extends out of the highlighted port. Arcs in that network will be drawn with dashed lines, and nodes in that network will be indicated with dots. The example here shows the highlighting of a pin node (in the upper-right) with a single-point port ("+") which is connected to a contact and a transistor. | ![]() |
It is important to understand that Electric is not exactly a WYSIWYG editor (what-you-see-is-what-you-get). Nodes that are touching on the screen may not actually be connected if there are no arcs joining them. The best way to ensure that the circuit is correct is to highlight a node and see the extent of the connections on it.
There are two ways to highlight an area. If you click the left button where there is no object, and hold it down while dragging over objects, all of those objects will be highlighted.
To more precisely define a highlighted area, switch to area selection (as opposed to object selection) with the Area command (in menu Edit / Modes / Select, or click on the "Area Selection" icon in the tool bar). | ![]() |
Once in area selection mode, each click and drag of the left button leaves the highlight rectangle on the screen exactly as it was drawn. You can convert this selection to a set of actual nodes and arcs with the Enclosed Objects command (in menu Edit / Selection).
Highlighted text appears as an "X" over the letters. However, text is a special case, so it will not be covered until later (section 6-8-2). For now, if you highlight some text, it is best to click again and select something else.
![]() |
There are some selection preferences that can be set with "Selection" preferences
(in menu File / Preferences..., "General" section, "Selection" tab).
"Easy selection" controls whether objects can be selected with simple clicks, or whether they require extra effort to select.
You can request that all cell instances be hard to select and that all annotation text be hard to select.
See the (next section) for more on this.
The "Dragging must enclose entire object" requests that area-selection completely enclose an object in order to select it. The default is that any object touching the area is selected. |
To prevent accidental moving of an object after selecting it, object movement is disabled for a short time after the selection click. This delay can be controlled.
When the cursor roams over a circuit, it shows a "preview" of what will be selected by the next click. The advance preview is shown in a different color than the actual highlighting (initially blue, but this can be changed with the "Color" Preferences, see Section 4-6-2). This feature is called "mouse-over highlighting". If you do not want to see this preview, uncheck "Enable Mouse-over highlighting".
To select hard-to-select objects, use the Special Select command (in menu Edit / Modes / Select). You can also click on the "Special Select" tool bar button to enable "special selection". | ![]() |
Ease of selection extends to more than just nodes and arcs. There are four "classes" of objects that can be selected:
Although all nodes and arcs are typically easy-to-select, you can control them individually by unchecking the "Easy to Select" field in their properties dialog (use the Object Properties... command in menu Edit / Properties). If multiple objects are selected, the Object Properties... dialog has a popup in the lower-right for changing their selection difficulty.
Special commands exist in the Selection menu for dealing with easy-to-select nodes and arcs. You can select all of the easy-to-select objects in the current cell with the Select All Easy command. Similarly, you can select those that are not easy-to-select with the Select All Hard command. To change the ease of selection for a set of objects, highlight them and use either Make Selected Easy or Make Selected Hard.
![]() |
2-2-1: Node Creation |
![]() |
The location of the cursor is aligned to the nearest grid unit. This adjustment can be controlled with the "Grid" preferences (in menu File / Preferences..., "Display" section, "Grid" tab).
When placing a node, the cursor points to the anchor point of the newly created node. This is the center (for primitives) or the location of the cell-center (for cell instances). Cell instances can change their anchor point by moving the Cell-Center node inside of their layout (see Section 3-3).
Besides basic components, there are special entries in the component menu for creation of additional nodes:
![]() |
These objects can be created with the "Misc" button:
|
If one node is highlighted, segment wiring is done, in which an arc is drawn from the highlighted node to the location of the cursor. If there is nothing at that location, a pin is created, and it is left highlighted. Using the right button again runs an arc from the pin to another location. By clicking and holding the right button, you can see the path that the new arc will follow.
In general, all wiring operations should be done by clicking and holding the right button, then moving the cursor until the intended wiring is shown, and finally releasing. This is recommended because wiring is quite complex and can follow many different paths.
If you type a digit key while the right button is pressed, it changes the wiring layer by inserting contacts to that layer of metal. For example, if you are running a metal-1 wire, and type "3" during the wiring, then two contacts will be added (metal-1-metal-2 and metal-2-metal-3) to make the wire run in metal-3.
If the cursor is over another object when the right button is released, the new wire attaches to that object. If there are multiple objects under the cursor, press the space bar (while the right button is pressed) to cycle through the possible endpoints (including the possibility of connecting to none of them).
The other way that the creation button can operate is two-point wiring, in which two nodes are highlighted and one or more arcs are created to connect them. Highlighting of these two nodes is done by clicking the left button over the first one, and then using the shift-left button on the second. Note that if the second node is obscured by other objects, you can cycle through the objects under the cursor with the control-shift-left button. Once the two nodes are highlighted, use the right button to wire them together. Note that the highlighted ports on the selected nodes are important: arcs will run between them, so they must be compatible in their wiring capabilities.
Two-point wire creation first attempts to run a single arc. Generally, this can happen only if the ports are lined up accurately. Failing single arc placement, an attempt is made to connect with two arcs and an intermediate node. These two arcs can bend in one of two directions, determined by the location of the cursor.
![]() | In addition to running an arc between two nodes, you can also use arcs as the starting or ending point of arc creation. If it is sensible, the creation command actually uses one of the nodes on an end of the selected arc. |
However, if the connection falls inside the arc, it is split and a new node is created to make a "T" connection.
Electric will allow you to connect two nodes or arcs as long as there is some way in the current technology for those objects to be connected. For example, if connecting between metal-1-pin and a metal-3-pin in the MOSIS CMOS technology, Electric will place metal-1-metal-2 and metal-2-metal-3 contact cuts down, and wire between all four nodes. When vias are inserted, they are placed closest to the "destination" node (or farthest from the original node).
As mentioned in Section 1-8, pressing the number keys for a valid layer switches to that layer. If a node is highlighted, it will route to that layer from the node, creating contacts as necessary.
Note that all arcs overlap their endpoint by half of their width, so very wide arcs may overlap their destination with too much geometry. You can turn off this overlap by using the Toggle End Extension of Head and Toggle End Extension of Tail commands (in menu Edit / Arc). See Section 5-4-3 for more on end extension.
An unusual circuit creation command is the Insert Jog In Arc command (in menu Edit / Arc). This command inserts a jog in the highlighted arc by replacing it with three new arcs. Two of the new arcs run to the location of the cursor, and the third arc is perpendicular to them, connecting the ends at the cursor location (initially it has zero length). Once the jog is inserted, either half of the arc may be moved without affecting the other half, and the perpendicular arc will keep the circuit connected. | ![]() |
Beginning users often leave many extra pins in their circuits. With the Cleanup Pins command (in menu Edit / Cleanup Cell), these pins are automatically removed from your circuit, leaving a cleaner network. The command does other pin organizations, such as making sure that text on these pins is located correctly, identifying zero-sized pins, and identifying oversized pins. The Cleanup Pins Everywhere command does this function for all cells at once.
![]() |
2-3: Circuit Deletion |
![]() |
Note that an arc always connects two nodes, and therefore it cannot remain if one of the nodes is gone. This means that certain rules apply to circuit deletion:
| ![]() |
![]() | When an area is selected (instead of objects) the Erase command erases all geometry in the highlighted area. All arcs that cross into that area will be truncated. Thus, this command truly erases geometry, independent of the structure of nodes and arcs. Note that the area to be erased is adjusted by the current alignment values (see Section 4-7-2). For more on area selection, see Section 2-1-3. |
![]() |
2-4-1: Movement |
![]() |
Another way to move objects is to use the arrow keys. When a node or arc is selected, each press of an arrow key moves that object by one grid unit. If the shift key or the control key is held, then the arrow keys move the object by a block of grid units. A block of grid units is defined in the "Grid" preferences (in menu File / Preferences..., "Display" section, "Grid" tab) to be the frequency of bold dots in the grid, initially 10. If you hold both the shift key and the control key, then the distance moved will be a block squared (i.e. initially 100).
The distance that the arrow keys move is also affected by the Movement commands (in menu Edit / Modes). These commands are also available in the tool bar. | ![]() |
The Quarter command causes the amount to be quartered (so unshifted arrow keys will move by a quarter unit). The Half command causes the amount to be halved (so unshifted arrow keys will move by a half unit). The Full command causes the amount to be full (so unshifted arrow keys will move by one unit). Note that these menu items are attached to the "q", "h", and "f" keys and are also in the tool bar.
To move objects along only one line (just horizontally or vertically but not both), hold the Control key down during motion. Note that holding the Control key down before clicking will change the nature of the mouse action, so you must click first, and then press Control. When editing schematics, this will constrain objects to movement along 45 degree angles.
When arcs are moved by a large amount, they cause the connecting nodes to move with them. However, for small arc motion, the arc may shift within its ports. This can only happen if the port has nonzero area and if the arc has the slidable constraint (shown with the letter "S" when highlighted). These constraints are discussed in greater detail in Section 5-2-2.
Another way to move a node is to use the Object Properties... command
(in menu Edit / Properties),
and type new X and Y positions.
This dialog allows other modifications to be made as well (orientation, etc.)
The dialog shows the location of the anchor-point of the node. | ![]() |
The dialog also has a field for the node's name. This name is not related to network information, but it can be used for identification. If a schematic node is given an arrayed name (such as "and[0:3]") then it indicates that the node is arrayed that many times. Nodes (and arcs) are automatically be given unique names (such as "nmos@0").
This dialog is modeless: it can remain on the screen while other editing is being done. If a different node is selected, the dialog updates to show that node's information. The "Apply" button changes the selected node to match the new values typed into the dialog.
The Object Properties... dialog can also expand to show more information. When the "More" button is clicked, it grows to full size as shown.
The full size Object Properties... dialog has many new controls,
which vary according to the type of node selected:
| ![]() |
The bottom of the expanded Object Properties... dialog has a scroll area that can view "Ports" or "Attributes". By default, a list of the node's ports is shown, including any exports, connections, and highlight details. If the "Attributes" button is selected, the list shows the attributes on the node. When "Attributes" is selected, the entries in the list let you modify individual values. Note that there is also an "Attributes" button, which brings up a full dialog for editing them.
If many objects are selected, you can move them by a specific distance with the Move Objects By... command (in menu Edit / Move).
![]() |
If many nodes are selected, the Properties... command will list all of them,
and allow position and size changes to be made at once to each in the group.
If a position and size value appears in the dialog,
it means that this value is the same on every selected node.
If the field is blank, it means that there are different values.
Changes are only made in the fields where you type a value. To remove an item from the list (not the circuit, just this list) use the "Remove" button. To remove all but the selected item, use "Remove Others". If only two objects are selected, this dialog shows the distance between their centers. |
The multi-object Properties... dialog also allows you to change selection ease with the "For everything:" popup (see Section 2-1-5 for more on selection styles). When many exports are selected, the dialog allows you to change their characteristics with the "For all selected exports:" popup (see Section 3-6-1 for more on exports).
![]() |
2-5-1: Node Sizing |
![]() |
If you hold the mouse button down while dragging, you can see the final size of the node. Release the mouse button to actually resize the node. To abort this operation, type Escape.
To constrain sizing so that only one dimension changes, hold the Control key while moving the mouse.
![]() | To change the size of more than one node at a time, select the nodes and use the All Selected Nodes... command (in menu Edit / Size). The dialog allows you to set the X and Y sizes of the selected nodes. If you leave one of these size fields empty, that coordinate is not changed. |
Note that when typing size amounts into a dialog, specify the size of the highlighted area. In a typical MOS transistor, the highlighted area (where active and polysilicon cross) is 2x3, even though the component is much larger if you include the four overlap regions sticking out.
Another way to change an arc's width is to select it and use the Object Properties... command
(in menu Edit / Properties).
Note that when typing size amounts into a dialog, specify the size of the highlighted area. A CMOS active arc shows highlighting only on its active area, even though the complete arc has implant regions that are much larger. The "Name" field lets you name an arc (see Section 6-8-1). Arc names are only displayed on the arc if they have been explicitly typed into this dialog. You can also use the "Props." button to show a dialog that controls all aspects of a displayed arc name. The "Easy to Select" checkbox enables selection of the arc with a simple click (see Section 2-1-5). | ![]() |
Many pieces of state can be changed here, including Rigid and Fixed-angle (see Section 5-2-1), Slidable (see Section 5-2-2), Directionality (see Section 5-4-1), Ends extension (see Section 5-4-3), and Negation (see Section 5-4-2).
When an Artwork arc has been selected (see Section 7-6-1), the "Color" field is available for setting its color.
![]() |
2-6: Changing Orientation |
![]() |
The Mirror command (in menu Edit) has a submenu that allows you to flip the currently highlighted objects about their vertical centerline (left/right mirroring) or their horizontal centerline (up/down mirroring).
Be aware that mirroring is not the same as rotating, even though both may produce the same visual results. Mirroring causes the node to be flipped about its horizontal or vertical centerline, and thus appear backwards.
![]() |
3-1: Cells |
![]() |
![]() |
Besides organizing cells into a hierarchy,
Electric also organizes cells into cell groups
and gives each cell a view and a version.
A cell's view describes its contents (for example "layout", "schematics", "netlist", etc.)
A cell's version defines its design age.
The full name of a cell is:
where CELLNAME is the name of the cell, VIEW is the abbreviated name of this cell's view, and VERSION is the version number of this view of the cell. When no version number is displayed, it implies that this cell is the most recent version (has the largest number). Thus, the cell "gate;2{lay}" is more recent than "gate;1{lay}" but less recent than "gate{lay}" (which must have a higher version number, probably 3). |
In this example, there is a library with two cell groups.
One group has a set of cells called "gate" and the other has a set of cells called "latch".
On the right is the explorer view of these cells.
See Section 4-8 for more on the cell explorer.
Although it is not necessary for cells in a group to all have the same name, the system presumes that common names will be grouped together. Once in a group, you can rename a cell to give it a different name than the others in its group. Use the Rename Cell... command (in menu Cell). You can also use context menus in the cell explorer to rearrange groups. | ![]() |
![]() |
3-2: Cell Creation and Deletion |
![]() |
![]() |
The New Cell... command requests a new cell name as well as its view and technology.
You can choose to show the cell in the current window, or create a new one.
Cell names may not contain spaces, tabs, unprintable characters, or a colon. Uppercase and lowercase characters are not distinguished: The cell "UPPER" is the same as the cell "Upper." However, the form of capitalization that is used when a cell is first created is retained for all further use. |
Another way to create a new cell is to make a copy of an existing one. The Duplicate Current Cell and Duplicate Cell... commands (in menu Cell) copy a cell to a different one with a new name (you will be prompted for the new name). The New Version of Current Cell command makes a copy of the cell in the current window, but since it is a "new version", it has the same cell name. The newly created cell is displayed in the window.
Once cells are created you can edit them with the Edit Cell... command (in menu Cell). Cells can also be edited by using the cell explorer (see Section 4-8 for more).
To delete a cell, use the Delete Cell... command (in menu Cell).
When deleting a cell, there cannot be any instances of this cell, or the deletion fails.
As a side effect of failure, you are shown a list of all other cells that have instances of this,
so you can see the extent of its use.
To find out whether a cell is being used elsewhere in the hierarchy, use the List Cell Usage
command (in menu Cell / Cell Info).
Because Electric is able to keep old versions of cells, deleting the latest version will cause an older version to become the "most recent". Old versions are those whose cell names include the ";VERSION" clause indicating that there is a newer version of this view of the cell. For example, if you have cell "Adder" and an older version "Adder;1", then deleting "Adder" will cause "Adder;1" to be renamed to "Adder". This might make you think that the deletion failed, because there is still a cell called "Adder", but this cell is actually the older (but now most recent) version. | ![]() |
To clean-up old and unused versions of cells, use the Delete Unused Old Versions command (in menu Cell). Any such cells that are no longer used as instances in other cells will be deleted from the library. You will get a list of deleted cells, and it is possible to undo this command.
![]() |
3-3: Creating Instances |
![]() |
![]() |
Another way to place an instance of a cell is to use the Place Cell Instance... command (in menu Cell).
You will be shown a list of cells that are available for creation.
After selecting one, click to create an instance in the current cell.
The cell selection dialog has three controls at the top for viewing cells. The "Library" popup lets you choose which library to examine. You can choose "ALL" to see cells from all libraries. The "View" popup lets you see only those cells in the specified view. Again, you can choose "All" to see all views. The "Filter" field contains a regular expression that must match a cell name in order to list it. If you place an instance from a different library, that library will be linked to the current one. Linked libraries are read from disk together, and form a single hierarchy that spans multiple files. See Section 3-9-1 for more on libraries. |
An alternate way to create a cell instance is to duplicate an existing one on the screen. This requires that an instance of that particular cell already exist. Select the existing cell and use the Duplicate command (in menu Edit). Then move the cursor to the intended location of the new instance and click to create the copy. Note that this command copies all attributes of the original node including its orientation.
When a cell instance is being created, the cursor points to its anchor point. The anchor point is that point inside of the cell where the coordinate space has its origin. This is often defined by the location of a cell-center node inside of the cell. | ![]() |
Most cells have a cell-center node placed automatically in them. If there isn't one and you want it, click on the "Misc" button in the component menu on the left, and choose "Cell Center". A cell-center node, placed inside of the cell definition, affects the anchor point for all subsequent creation of instances of the cell.
![]() |
3-4: Examining Cell Instances |
![]() |
Once expanded, a cell instance will continue to be drawn with its contents shown until the commands of the Cell / Unexpand Cell Instances command are used. These commands return cell instances to their black-box form, starting with the deepest subcells that are expanded at the bottom of the hierarchy. The One Level Up command closes up the bottommost expanded level; the All the Way command closes all levels from the bottom; and the Specified Amount... lets you type a number of levels of hierarchy to close.
You can also use the expansion (opened eye) and unexpansion (closed eye) icons from the tool bar to expand and unexpand by one level. | ![]() |
The expansion information can also be set or reset by using the Object Properties... command (in menu Edit / Properties) and clicking on the "Expanded" or "Unexpanded" buttons.
There are times when you want to see the layout inside of a cell instance, but only temporarily. The Look Inside Highlighted command (in menu Cell) displays everything in the highlighted area, down through all hierarchical levels. This is a one-shot display that reverts to unexpanded form if the window is shifted, scaled, or redrawn.
There is a slight difference in specification between the Expand Cell Instances commands and the Look Inside Highlighted command. The Expand Cell Instances commands affect cell instances only, and thus any instances that are highlighted or in the highlighted area will be completely expanded. The Look Inside Highlighted command affects layout display in an area, so only those parts of instances that are inside of the highlighted area will be shown. Thus, the command Look Inside Highlighted is more precise in what it expands and can be used, in conjunction with Area selection, to show only a specific part of the circuit (see Section 2-1-3 for more on area selection).
![]() |
3-5: Moving Up and Down the Hierarchy |
![]() |
To edit a cell instance, use the Down Hierarchy command (in menu Cell). This command will descend into the definition of the currently selected cell instance. The contents will appear at the same size and location as the instance, and you will now be able to edit the contents.
If an icon is selected, the Down Hierarchy command will take you to the associated schematic. If the icon that is selected is already in its own schematic (you can place an icon inside its own schematic for documentation purposes), then the Down Hierarchy command takes you to the actual icon so that you can edit it.
If a layout cell is selected, you can use the Down Hierarchy In Place command to edit the cell while showing the upper level of the hierarchy. The surrounding geometry at the upper level is not editable, and is grayed-out.
Schematic nodes can be arrayed by giving them array names (see Section 6-9-3). When you descend into an arrayed node, the system does not know which element of the array you are entering. Most of the time, the specific element is irrelevant, but if the circuit is being simulated, the specific instance may be necessary for cross-probing. Therefore, if the cell is being simulated and you descend into an arrayed node, you will be prompted for the specific element that you wish to visit. There are other situations that cannot be detected, where the specific element needs to be known. To solve this problem, you can request that Electric prompt for the specific element in all situations where an arrayed node is visited. To do this, check "Always prompt for index when descending into array nodes" in the "General" preferences (in menu File / Preferences..., "General" section, "General" tab)
The Up Hierarchy command pops you to the next higher cell in the hierarchy. If there was an associated Down Hierarchy command, then this returns you to the place where you started, up the hierarchy. If the Down Hierarchy commands were not used, Electric attempts to figure out the next higher cell in the hierarchy, switching icons for schematics where appropriate. If there are multiple possibilities (because the current cell is used in many locations) then you will be prompted for a specific location.
Besides using the Up Hierarchy and Down Hierarchy commands, you can also use the tool bar "back" and "forward" buttons to move through the hierarchy. | ![]() |
If you right-click on these icons, you are given a list of cells and can jump directly to one of them.
When going down or up the hierarchy, if an export or port is selected, then the equivalent port or export is shown after the level of hierarchy has changed.
![]() |
3-6-1: Export Creation |
![]() |
To see the location of all ports on the selected nodes, use the Show Ports on Node command (in menu Export).
To create an export, select a port on a node and use the Create Export... command (in menu Export). The resulting dialog requests an export name and some characteristics. | ![]() |
All export names on a cell must be unique; if a nonunique name is given, it is modified to be unique. This modification involves adding "_1", "_2", etc. to the end of scalar export names, or changing the index (from [1] to [2], etc.) for arrayed export names. Like cell names, export names may not contain spaces, tabs, or unprintable characters. Although no case distinction is made between uppercase and lowercase characters; the original case usage is preserved.
Behavioral characteristics can be associated with an export by selecting the appropriate field in the export creation dialog. These behavior characteristics are stored with the export and used primarily by simulators. The characteristics include the following:
The "Always drawn" check box requests that the export label should always appear, regardless of the connection or expansion of its cell. Typically, an export label on an instance of a cell is not displayed when that port is connected to an arc or when the instance is expanded. This check box overrides the suppression.
Another special check box, "Body only," requests that this export not appear when an icon is generated for the cell. This is useful for power and ground exports or duplicate connection sites on a single network.
There are many special exporting commands that are primarily used in array-based layout. If a cell instance is replicated many times and the instances are wired together, then ports on the edge of the array are the only ones that are not wired. These ports define the connections for the next level of hierarchy. What you want to do is to create exports for all unwired ports on all cell instances. To do this, use the Re-Export Everything command (in menu Export), which generates unique names as it exports all unwired ports on cell instances. To do this same function, but only on the currently highlighted nodes, use Re-Export Selected. To do this same function, but inside of the highlighted area, use Re-Export Highlighted Area. These two commands can also be run so that wired ports are re-exported, by using the Re-Export Selected, With Wired Ports and Re-Export Highlighted Area, With Wired Ports To do this same function, but only for Power and Ground exports, use Re-Export Power and Ground. Note that ports on primitive nodes are not exported with these commands. See Section 6-4 for more about arrays, and see Section 9-6-1 for more on automatic wiring.
Another special command for export creation is Add Export from Library..., which copies exports from another library to the current one. The other library is examined for cells whose names match ones in the current library. When a cell is found in the other library, all of its exports are copied to the cell in the current library (if they don't already exist) and placed in the same location. This command is useful in managing standard cell libraries that are imported from other file formats (see Section 3-9-4 on Standard Cell Libraries). Because some formats contain geometry and others contain connectivity, this command is needed to put them together.
To see all exports that have been defined in the current cell, use the Show Exports command (in menu Export). The List Exports command gives the same information, but in text form, and the Summarize Exports command gives a text list that is reduced where sensible. To see a list of exports that are electrically connected to the current object, at multiple levels of hierarchy, use the List Exports on Network and List Exports below Network commands (in menu Tool / Network).
Once a port has been exported, its characteristics can be modified by selecting the export name and using the Object Properties... command (in menu Edit / Properties). You can change basic export information such as the name, characteristic, and reference name (if applicable). You can control export state such as whether it is always drawn, and whether or not it appears on icons. You can also change the appearance of the export by editing the size, font, color, style, anchor point, and rotation of the name. See Section 6-8-1 for more about text appearance. | ![]() |
Special buttons in the Export Properties dialog allow you to examine related objects. The "Highlight Owner" button shows the node on which this export resides, and the "Attributes" button brings up an Attributes dialog for the export (see Section 6-8-5 for more on Attributes).
You can change the characteristics of many exports at once by selecting them and using the Object Properties... command (in menu Edit / Properties). This multi-object dialog has a "For all selected exports:" popup that will change all export characteristics at once. You can change the name of exports by using the Rename Export... command (in menu Export).
Ports and exports can be displayed on the screen in many different ways. To control this, use the "Ports/Exports" preferences (in menu File / Preferences..., "Display" section, "Ports/Exports" tab). The dialog offers three options for ports and exports: "Full Names" shows full text names, "Short Names" shows port and export names only up to the first nonalphabetic character, and "Crosses" shows crosses at the locations. | ![]() |
With short names, the exports "Power-left" and "Power-1" are both written as "Power," which allows multiple exports with the same functionality but different names to be displayed as if they have the same name. To remove port display completely, use the "Layers" tab of the side bar (see Section 4-5). In this panel are options to make exports text completely invisible.
To remove many exports at once, the Delete Exports on Selected command removes all exports on all highlighted nodes. Also, the Delete Exports in Highlighted Area command removes only those exports that are in the selected area . When an export is deleted, all arcs connected to that port on instances of the current cell (higher up the hierarchy) are also deleted.
To move export text, simply select it and drag it. The location of the text has no effect on the location of the export: moving the text is only for improvement of the display. However, if you check "Move node with export name" in the "Ports/Exports" preferences (in menu File / Preferences..., "Display" section, "Ports/Exports" tab), then moving an export name will cause the node (and the export) to move as well.
It is sometimes desirable to keep an export but to transfer it to another node. If a cell is in use higher in the hierarchy, unexporting and then reexporting deletes all existing connections. Instead, the Move Export command (in menu Export) can be used. Before using this command, two nodes and their ports must be highlighted with left button and shift-left button. The export is moved from the first node to the second node.
![]() |
3-7-1: Cell Lists |
![]() |
To get some basic information about the current cell
(size, dates, etc) use the Describe this Cell command
(in menu Cell / Cell Info).
To get information about more than one cell, use the General Cell Lists... command. The dialog selects a subset of the cells in the current library. The section labeled "Which cells:" selects the cells to be listed (all, only those used in other cells, only those NOT used in the current cell, only those in the current cell, or only "placeholder" cells: those created because of cross-library dependency failures, see Section 3-9-1). The section labeled "View filter:" allows only certain views to be displayed. The section labeled "Version filter:" allows removal of older or newer versions of cells. The section labeled "Display ordering:" controls the order in which the selected cells will be listed. The section labeled "Destination:" allows you to dump this listing to a disk file, formatted for spreadsheets (tab-separated). | ![]() |
The result of cell information listing looks like this:
-Cell------------Version----Creation date----------Revision Date---------Size----Usage--L-I-C-D tech-Artwork{} 1 Dec 31, 1969 16:00:00 Dec 15, 2004 11:34:15 131.0x83.0 0 L tech-Bipolar{ic} 1 Dec 15, 2004 11:34:25 Dec 15, 2004 11:34:25 10.0x12.0 1 tech-Bipolar{lay} 1 Jul 23, 1990 23:25:49 Dec 15, 2004 12:38:11 37.0x73.5 0 tech-Bipolar{sch} 1 Jul 26, 1990 23:58:58 Dec 15, 2004 11:34:27 58.75x59.5 0 L I tech-DigitalFilter{} 1 Dec 31, 1969 16:00:00 Dec 01, 2000 13:56:47 48.0x45.5 0 tech-MOSISCMOS{lay} 1 Jul 24, 1998 16:10:55 Dec 09, 2001 12:35:29 85.5x83.0 0 D tech-PCB7404{} 1 Dec 31, 1969 16:00:00 Dec 15, 2004 11:45:03 12.5x28.5 1 tool_NCC{sch} 1 Mar 27, 2001 06:35:49 Jan 25, 2002 15:57:57 44.0x41.5 0 L I
The last five columns show the usage and four state bits. The usage is the number of times that this cell appears as an instance in other cells. The state bits are:
For more cell information, use the commands of menu Cell / Cell Info. The List Nodes in this Cell command shows all nonprimitive nodes in the current cell. The List Cell Instances command shows all cell instances below the current cell. The List Cell Usage command looks up the hierarchy and finds cells that contain the current cell as an instance.
The Graphically, Entire Library command (in menu Edit / Cell Info) displays a graph of every cell in the library. The Graphically, From Current Cell command displays a graph that places the current cell at the top. These commands create a graph of the cell hierarchy. This graph is actually a new cell, called "CellStructure", built from Artwork nodes, and stored in the current library. | ![]() |
The checkbox "Disallow modification of anything in this cell", allows you to control whether the contents of a cell is editable or not. When modification is disallowed, no changes may be made. This is useful when you want to allow examination without accidental modification.
The checkbox "Disallow modification of instances in this cell", also prevents changes to the selected cell, but in this case, only instances of sub-cells are locked. This is useful when you have a correct instance placement and are doing wiring.
If you make a change that has been disallowed, a dialog appears that asks if you want to override the lock. You may make the change ("Yes"), disallow the change ("No"), or remove the lock ("Always", which unchecks the locks in this dialog). | ![]() |
The check box "Part of a cell-library" indicates that this cell is from a library of standard cells and should be treated accordingly.
The check box "Part of technology editor library" indicates that this cell helps to define a technology. For more on the technology editor, see Section 8-1.
For the first 4 checkboxes in this dialog, there are buttons on the right which allow you to set or clear these flags for all cells in the library.
The "Expand new instances" and "Unexpand new instances" buttons choose whether newly created instances of this cell are expanded (contents visible) or unexpanded (drawn with a black outline) See Section 3-4 for more on expansion.
The "Characteristic Spacing" is the spacing of this cell when arrayed (see Section 6-4).
Each cell is tied to a specific technology. The cell's technology is set when the cell is created. You can change the technology that is associated with a cell by using the "Technology" popup.
The lower-right has frame controls for the cell. The frame is a border that is usually drawn around schematics. You can set the frame size, whether it is wider (Landscape mode) or taller (Portrait mode), and whether a title box is drawn in the corner. Additionally, you can set the designer name to be drawn for each cell. Other information in the title box (company name, project name) are set on a per-user or per-library basis with the "Frame" preferences (in menu File / Preferences..., "Display" section, "Frame" tab). See Section 7-5-2 for more on frames.
![]() |
3-8: Rearranging Cell Hierarchy |
![]() |
The opposite function is the removal of levels of hierarchy. This is done with the Extract Cell Instance command, which takes the currently highlighted cell instances and replaces them with their contents. Repeated use of this command goes further down the hierarchy until it is fully instantiated. All arcs that were connected to the cell instances are reconnected to the correct parts of the instantiated circuitry.
![]() |
3-9-1: Introduction to Libraries |
![]() |
To create a new, empty library, use the New Library... command (in menu File). To change the name of the current library, use the Rename Library... command. To delete a library, use the Close Library command. This removes only the memory representation, not the disk file. Note that library changes are too vast to be tracked by the database-change mechanism and so are not undoable.
It is possible to link two libraries by placing an instance of a cell from one library into another (this is done with the Place Cell Instance... command in menu Cell). When this happens, the library with the instance (the main library) is linked to the library with the actual cell (this is the reference library). Because the reference library is needed to complete the main library, it will be read whenever the main library is read.
If referenced libraries are edited independently, it is possible that a reference to a cell in another library will not match the actual cell in that library. When this happens, Electric creates a "placeholder" cell that matches the original specification. Thus, the link to the referenced library is broken because the cell there does not fit where the instance should be. To see a list of all placeholder cells that were created because of such problems, use the General Cell Lists... command (in menu Cell / Cell Info) and select "Only placeholder cells".
When reading and writing libraries, Electric offers a number of ways to choose the directory in the file system. The choices are available in the "Working directory" field of the "General" preferences (in menu File / Preferences..., "General" section, "General" tab):
Electric comes with some built-in libraries. There are two Spice primitive libraries (see Section 9-4-3). A library of examples can be loaded with the Load Library command (in menu Help / Samples). A set of MOSIS CMOS pads can be loaded with the MOSIS CMOS Pads command (in menu Help / Load Built-in Libraries). A set of gates, useful for Logical Effort (see Section 9-9), can be loaded with the Load Logical Effort Libraries (Purple, Red, and Orange) command (in menu Tool / Logical Effort).
You can also use the open-library icon from the tool bar. | ![]() |
Electric users with very old ".elib" files may have difficulty reading them into Electric. If you have been using versions of Electric prior to 7.00, it may help to upgrade to that version and read the libraries. Saving ".elib" files from version 7.00 will work properly in the current system.
By default Electric searches for libraries in the working directory, absolute file path references, and Electric's internal library directory. Users can specify additional directories to search by using a file called "LIBDIRS" placed in the working directory. This file specifies additional paths to search for library files. The file has the following syntax:
* <comments>
include <another_LIBDIRS_file>
<library_directory>
Paths may be absolute or relative.
Besides Electric libraries, it is possible to read circuit descriptions that are in other formats with these commands in the File / Import menu:
The Save All Libraries command writes all libraries that have changed. You can also use the save-libraries icon from the tool bar. To force all libraries to be saved, use the Mark All Libraries for Saving command, or use Save All Libraries in Format to specify how they are to be saved. | ![]() |
If a library was read from disk, it is written back to the same file. If, however, you wish to write the library to a new file (thus preserving the original) then use the Save Library As... command.
The "Library" preferences (in menu File / Preferences..., "I/O" section, "Library" tab) offers options for writing libraries to disk. By default, saved libraries overwrite the previous files and no backup is created. If you choose "Backup of last library file", then the former library is renamed so that it has a "~" at the end. If you choose "Backup history of library files", then the former library is renamed so that it has its creation date as part of its name. | ![]() |
Electric can also write external format files with these commands in the File / Export menu:
![]() | The exported files from Electric are often considered to be proprietary information, and must be marked appropriately. Copyright information can be inserted into exported files with the "Copyright" preferences (in menu File / Preferences..., "General" section, "Copyright" tab). Since each export file has a different format for comments, the copyright text should not contain any such characters. Instead, the system will insert the proper comment characters for the particular export format. |
The copyright information will be inserted into decks exported for CIF, LEF, and PostScript, as well as in simulation netlists for Verilog, Spice, Silos, ESIM/RSIM/RNL/COSMOS, FastHenry, Maxwell, and IRSIM.
Artisan libraries are not distributed in Electric format. Instead, they come in a variety of formats that can be read into Electric. The GDS files contain the necessary geometry, and the LEF files contain the connectivity. By combining them, Electric creates a standard cell library that can be placed-and-routed and can be fabricated. Note that the data is not node-extracted, so not all of Electric's capabilities can be used with this data.
To create an Artisan library, follow these steps:
![]() |
3-10: Copying Cells Between Libraries |
![]() |
The Cross-Library Copy... command (in menu Cell) provides a dialog for copying cells between libraries.
The left and right columns show the contents of two different libraries
(and the pulldowns above each column let you select the two libraries that you want to use).
When there is a cell with the same name in both libraries, the system compares them to determine which is newer. | ![]() |
If you check "Date and content" (and then "Compare" to do comparison again) Electric will compare the actual contents of cells when determining their equality. Unchecking "Examine quietly" will cause the system to describe differences found during comparison.
By choosing a cell in the right-hand library and clicking "<< Copy", that cell is copied into the left-hand library. The "Copy >>" button does the reverse. If "Delete after copy" is checked, the buttons change to "<< Move" and "Move >>".
The system can be requested to copy additional cells that relate to the selected one. By checking "Copy subcells", all subcells of the copied cell are also transfered. By checking "Copy all related views", all related views (icon, schematic, layout, etc.) are also transfered. Note that if "Copy all related views" is off but you want to "Copy subcells", it still copies related views in a limited fashion (i.e. schematics and icons are copied together).
When there is a reference to an instance inside of a copied cell, and that instance already exists in the destination library, there are many ways to handle the transfer. For example, library "Frank" has cell "A" which has, inside of it, an instance of cell "B" ("B" is also in library "Frank"). You want to copy cell "A" to library "Tom", but there is already a cell called "B" in library "Tom". These things may happen:
![]() |
3-11-1: Setting a Cell's View |
![]() |
When creating a cell with the New Cell... command, you can specify its view. After creation, you can change the current cell's view with the Change Cell's View... command (in menu View). You can also use context menus in the cell explorer to change a cell's view. Note that this is one of the few commands in Electric that is NOT undoable. | ![]() |
When editing cells with text-only views (VHDL, Documentation, etc.), the window becomes a text editor. You may then use the Text Cell Contents... commands (in menu File / Export and File / Import) to save and restore this text to disk. See Section 4-10 for more on text editing.
The commands to edit another view work only when that cell exists. To create a new cell of a particular type, use the Make... commands of the View menu. These view conversion commands are available:
If the list of possible views is not sufficient to describe a cell,
new views can be created with the View Control... command (in menu View).
This command shows all views and lets you create and delete them.
When creating a new view, a name and an abbreviation are required. The abbreviation should be the first few letters of the full view name. This abbreviation will be used when describing cells with that view. For example, the view "fast-layout" might have the abbreviation "fast". | ![]() |
The "Text View" checkbox indicates that this is a text-only view, like "Documentation", "Netlist", "Verilog", and "VHDL".
To delete a view, use the "Delete" button. You can delete only the views that you have created, not the basic views that exist on startup (such as "layout", "schematic", etc). Also, there must be no cells with the view that is being deleted.
To generate an icon cell automatically, use the Make Icon View command (in menu View). Be sure to create all relevant exports before issuing this command, so that the proper icon can be constructed. Note that any export that has its "Body only" attribute checked will be omitted from the icon.
To control the look of the icons, use the "Icon" preferences (in menu File / Preferences..., "Technology" section, "Icon" tab). The top part of the dialog lets you place each of the different export types on any of the four sides of the icon.
The middle section of the dialog controls the body and leads of the icon.
You can choose whether or not to draw the body and leads. You can set the spacing and length of leads. You can choose the location of the exports (at the end of the leads, in the middle of the leads, or on the body). You can choose the style of the export text (whether it grows inward, outward). | ![]() |
The bottom part of the dialog has miscellaneous controls. You can choose the technology of the exports ("Universal" uses nodes from the Generic technology which can connect to any arc; "Schematic" uses nodes from the Schematic technology and can connect only to other Schematic arcs). Exports are arranged alphabetically around the icon, and you can choose to reverse the alphabetical order. Finally, you can choose the location of the icon instance in the original schematic (when you use the Make Icon View command, it generates the icon and places an instance of that icon in the schematic). A button at the bottom requests that an icon be made now, and takes the place of the Make Icon View command.
The icon cell is correctly tied to its contents in most respects. If you descend into it (with the Down Hierarchy command in menu Cell), then you actually find yourself editing the associated contents cell. The Up Hierarchy command properly returns you to the location of the icon instance. Also, the network consistency checker and the simulators correctly substitute the contents whenever an icon appears. In order for this to work, however, all exports in the contents cell must exist with the same name in the icon cell (with the exception of those that are marked "Body Only").
![]() |
4-1: The Tool Bar |
![]() |
The tool bar has these sections:
![]() |
4-2: The Messages Window |
![]() |
The text in the messages window can be selected with the cursor and edited with the Cut, Copy, and Paste commands (in menu Edit). You can remove all text with the Clear command (in menu Window / Messages Window). In addition, you can right-click in the messages window to Cut, Copy, Clear, or Paste the selected text. You can also use the right-click context menu to Cut or Copy all of the text in the window.
The text in the messages window can be saved to disk by using the Save Messages... command (in menu Window / Messages Window). You will be prompted for the place to save the text. You can select the messages window font with the Set Font... command.
![]() |
4-3: Creating and Deleting Editing Windows |
![]() |
New windows are created by checking the appropriate checkbox in the New Cell... or Edit Cell... commands (in menu Cell). New windows can also be created from the cell explorer by using the context button on a cell name.
To delete a window, click its close box, or use the Close Window command (in menu Window). Note that you cannot delete the last window on UNIX systems, because the UNIX pulldown menus are part of the edit windows.
When there are many editing windows on the display, you can arrange them neatly with the Window / Adjust Position commands. The Tile Horizontally command adjusts the windows so that they are full-width, but just tall enough to fill the screen, one above the other. The Tile Vertically command adjusts the windows so that they are full-height, but just wide enough to fill the screen, one next to the other. The Cascade command adjusts the windows so that they are all the same size and overlap each other uniformly from the upper-left to the lower-right.
![]() |
4-4-1: Scaling |
![]() |
During normal editing, you can zoom the display with the shift-right button (see Section 1-8). Holding shift-right while dragging a rectangular area causes the display to zoom into that area, making it fill the screen. Clicking shift-right in a single location causes the display to zoom out, centered at that point.
You can also use the Zoom tool from the tool bar to zoom in and out. This has the same zoom in and out functions, but they are now attached to the left button (no shift needed). To zoom into an area, click and drag out that area. To zoom out, hold the shift key and click in the center of the desired area. This mode can also be invoked with the Toggle Zoom command (in menu Edit / Modes / Edit). | ![]() |
The most useful scale change command is Fill Window (in menu Window), which makes the current cell fill the window.
To examine a specific area of the display, use the Focus on Highlighted command (in menu Window / Special Zoom), which makes the highlighted objects fill the display. To examine a specific area of the display that is not necessarily aligned with nodes and arcs, use the area select commands (see Section 2-1-3). You can also use the Zoom Box command, which allows you to drag-out a rectangle, and then zooms to that area.
The Make Grid Just Visible command (in menu Window / Special Zoom) zooms in or out until the grid is minimally visible. Any futher zoom-out from this point will make the grid invisible. If the grid is not being displayed, it is turned on. See Section 4-7-1 for more on the grid.
A final scaling command is Match Other Window which redraws the current window at the same scale as the other. If there are more than two windows, you will be asked to select the window to match.
You can also use the Pan tool from the tool bar to move the window contents. And this mode can be invoked with the Toggle Pan command (in menu Edit / Modes / Edit). | ![]() |
In addition to these methods, panning can also be done from menu commands. The Pan Left, Pan Right, Pan Up, and Pan Down commands (in menu Window) all shift the window contents appropriately (and because they are bound to quick keys, these operations can even be done from the keyboard). By default, these commands shift the screen by about 30% of its size. You can use the "General" preferences (in menu File / Preferences..., "General" section, "General" tab), to change that amount. The Small panning distance causes subsequent shifts to be about 15% of the screen size. The Medium panning distance causes subsequent shifts to be about 30% of the screen size. The Large panning distance causes subsequent shifts to be about 60% of the screen size.
The Center commands (in menu Window) are rarely-used panning commands for shifting the window contents without scaling. There are two commands: Selection makes the window shift so that the highlighted objects are in the center of the window, and Cursor makes the window shift so that the current cursor location is in the center of the window. Note that this second command is useful only when bound to a keystroke, because you cannot issue the command and have a valid cursor location at the same time.
One final command is useful if the display appears incorrect. If this happens, redraw the screen with the Redisplay Window command (in menu Window).
Once a particular scale and position is established in a window, you can save it and retrieve it later. The Saved Views... command (in menu Windows) presents a dialog that lists saved views. You can name the current view and save it with the "Save This View" button. A previously saved view can be displayed with the "Restore View" button. | ![]() |
![]() |
4-5: Layer Visibility |
![]() |
The nodes and arcs on the display are composed of more basic layers.
By using the "Layers" tab of the Side Bar,
you can control which layers are actually drawn.
The layers tab shows the layers in the current technology. Changing the technology popup at the top of this tab will change the current technology. When a layer is checked, it is visible. You can turn the check on and off by double-clicking on a line. You can also use the "Make Visible" and "Make Invisible" buttons. The "Select All" button selects every layer so that the "Make..." buttons will work on the entire set. Note that the layers are listed in order of height, and that you can select multiple entries in the list by using the Shift key. This means that you can easily control visibility by depth in the chip. Two buttons in the middle control the highlighting of layers. By selecting a layer and clicking "Toggle", it makes that layer stand out on the display. Use "Clear" to return to normal layer display. The bottom of the tab lets you choose which of the different types of text will be visible. These different types of text are described more fully in Section 6-8-1. | ![]() |
![]() |
4-6-1: Electric's Color Model |
![]() |
Every layer in a technology is either transparent or opaque. Transparent layers are able to overlap each other, and it is possible to see all of them. Typically, the most commonly used layers are transparent because it is clearer to distinguish.
The remaining layers in a technology are opaque, meaning that when drawn, they completely obscure anything underneath. These layers typically have stipple patterns so that they do not cover all of the bits. In this way, the opaque layers can combine without obscuring the display. Because opaque color does obscure everything under it, the less common layers are drawn in this style.
When editing colors, the opaque layers have only one color, whereas the transparent layers have many different colors, considering their interaction with other transparent layers.
When changing the background color, note that it must contrast with both the highlight color and the inverse of the highlight color (the inverse is black in the default settings).
Electric has three different color schemes which have predefined colors. The commands of the Window / Color Schemes menu let you switch between them. With the Black Background Colors command, the background becomes black; with the White Background Colors command, the background becomes white; with the Restore Default Colors command, the background becomes gray (the default).
Each layer has a color and pattern in the top section. You can draw in the pattern area to set a pattern, and you can choose from a set of predefined patterns by clicking on their image below the pattern-editing area.
A layer's color is only editable if it is opaque.
When transparent, you must use the "Colors" tab to set the color.
Two sections at the bottom control the appearance of the layer on the screen and on the printed page. The display section lets you assign the layer to one of the transparent layers. You can also choose whether to draw the layer in solid colors or use the specified pattern (and if patterned, you can choose to outline the pattern or not). | ![]() |
The printing section also lets you choose patterned vs. solid and whether to outline the pattern. In addition, it lets you set an opacity which will control its appearance on the printed page.
![]() |
4-7-1: Drawing a Grid |
![]() |
Initially, the grid dots are spaced 1 unit apart. The size of a grid unit can be related to real-world distance by considering the scale of the technology. For example, in the MOSIS CMOS technology, the scale is 0.2 microns, as shown in the status area. When the grid is displayed, the dots are therefore 0.2 microns apart. For more information on scaling, Section 7-2-1.
Note that the grid display changes as you zoom in and out. When zoomed too far out to show all of the dots, only the bolder dots are shown. When zoomed too far out to show even the bolder dots, the grid is not displayed. However, the fact that the grid should be on is remembered, so it reappears when you zoom back in.
The "Grid" preferences (in menu File / Preferences..., "Display" section, "Grid" tab)
presents a dialog in which grid spacing may be set.
You can change the grid spacing for the current window,
and also set a default grid spacing to be used in new windows.
It is possible to change the horizontal and vertical grid dot spacings. You can also change number of grid dots between bold ones. | ![]() |
The grid spacing is used by arrow keys when they move objects (see Section 2-4-1 for more on arrow key motion).
![]() |
The "Grid" preferences (in menu File / Preferences..., "Display" section, "Grid" tab) presents a dialog in which alignment values may be set. For example, if the grid spacing is 2x3, and the alignment is 0.5, then there are up to six different positions for placement inside a displayed grid rectangle. |
The Align to Grid command (in menu Edit / Move) cleans up the selected objects by moving them to aligned coordinates. This is useful for circuitry that has been imported from external sources, and needs to be placed cleanly for further editing.
The command Align Horizontally to Left (and Align Horizontally to Right) moves all of the objects so that their left edge (or right edge) is moved to the leftmost (or rightmost) location of those objects. The command Align Horizontally to Center moves all of the objects so that their X center is at the location of the X center coordinate of those objects.
The command Align Vertically to Top (and Align Vertically to Bottom) moves all of the objects so that their top edge (or bottom edge) is moved to the topmost (or bottommost) location of those objects. The command Align Vertically to Center moves all of the objects so that their Y center is at the location of the Y center coordinate of those objects.
If you wish to find the distance between any two points on the display, use the "Measure" tool from the tool bar. | ![]() |
This mode can also be invoked with the Toggle Measure Distance command (in menu Edit / Modes / Edit). Another way to measure distances is to use the cursor coordinates, displayed in the status area.
In measure mode, each click places a new point on the display, and shows the distance to the previous point. Clicking the right button lets you start a new measure point without connecting it to the previous one. Double-clicking the right button removes the measurements.
The measured distance can be used by the Array... command (in menu Edit) to specify spacing (see Section 6-4).
![]() |
4-8: The Cell Explorer |
![]() |
The cell explorer resides in the "Explorer" tab of the side bar. It shows a hierarchical tree with three main sections: LIBRARIES, JOBS, and ERRORS.
![]() |
The LIBRARIES section of the explorer lists all libraries and cells.
You can examine them in three different ways:
|
The second section of the explorer is the JOBS section. Here are listed all running tasks in Electric. The section is usually empty, but if multiple jobs are running at the same time, you can examine them and manipulate them.
The third part of the cell explorer is the ERRORS section. This lists all errors that were generated by other tools (DRC, ERC, NCC, etc.) and which can be examined with the "<" and ">" keys.
Many special functions can be done in the cell explorer. You can double-click on any cell name to see that cell in the right half of the window. There are special context menus available by right-clicking on an entry (use command-click on the Macintosh).
The context menu for the LIBRARIES icon has 3 parts. The top three entries let you control the expansion of the tree. The middle entry lets you create a new cell. The bottom three entries lets you view the libraries in different ways (explained above). | ![]() |
![]() | The context menu for each library icon has 5 parts. The top three entries let you control the expansion of the tree. The next entry lets you make the library the current library. The next entry lets you manage the library with Project Management (see Section 6-12). The next entry lets you create a new cell in the library. The bottom three entries let you rename, save or delete the library. |
The context menu for each cell icon has 5 parts. The top two entries let you edit the cell (in the current or in a new window). The next two entries let you place an instance of the cell and create a new cell. The next three entries let you create a new cell version, create a new cell copy, or delete the cell. The next two entries let you rename the cell or change its view. The bottom entry lets you rearrange cell groups. | ![]() |
![]() | The context menu for each cell group has 2 parts. The top three entries let you control the expansion of the tree. The bottom entries let you create a new cell in the group, or rename every cell in the group. |
The context menu for a multi-page schematic cell has two parts (see Section 7-5-2 for more on multi-page schematics). The top two entries let you edit the cell (in the current or in a new window). The bottom entries let you add a new page to the current multi-page schematic, or delete the current page of the multi-page schematic. | ![]() |
![]() |
The context menu for individual jobs under the JOBS icon has 3 entries: "Get Info" requests any additional information about the job; "Abort" requests that the Job stop itself (not always possible); and "Delete" removes a job from the queue. |
The context menu for each collection of errors in the ERRORS section has 3 entries: "Delete" removes this set of errors; "Save" saves the errors to a disk file; and "Set Current" makes this the current set of errors (which can be examined with the "<" and ">" keys). | ![]() |
![]() |
4-9: Printing |
![]() |
As an alternative to printing, you can request the system to write a PostScript, HPGL, or PNG file. To do this, use the PostScript..., HPGL, and PNG (Portable Network Graphics)... commands (in menu File / Export).
For specific printing and PostScript settings, use the "Printing" preferences (in menu File / Preferences..., "General" section, "Printing" tab).
The "For all printing" section at the top has some general options. The default is to include the entire cell, but you can choose to print only what is highlighted or only what is displayed by selecting the appropriate buttons. | ![]() |
Note that when printing the highlighted area, a precise selection can be made with Area selection (see Section 2-1-3).
The "Plot Date In Corner" option causes additional information to appear in the corner of the plot.
The "Print resolution" is the number of dots-per-inch (DPI) that the printer expects. Higher resolutions use more memory for the print image.
There are many PostScript options, available in the lower section.
![]() |
4-10: Text Windows |
![]() |
Some cells are textual in nature (VHDL, Verilog, Netlists, or Documentation), and cause text to appear in the edit window.
When text editing, the standard point-and-click commands apply. You can use the Cut, Copy, and Paste commands (in menu Edit). | ![]() |
The contents of a text window can be saved to disk with the Text Cell Contents... command (in menu File / Export) and restored from disk with the Text Cell Contents... command (in menu File / Import).
Note that there is no "saving" of text windows because they are editing internal data structures. Therefore every change updates the information in Electric (but the library must be saved to truly preserve changes).
![]() | Searching is done with the Find Text... command (in menu Edit / Text). You can find and/or replace text with the appropriate buttons. Check boxes allow the search to be case sensitive, have regular expressions, and to go in the reverse direction. In addition, you can jump directly to a specified line number. |
Interestingly, the Find Text... command can also be used outside of the text edit window. If you are editing a layout or schematic, this dialog will search all of the node, arc, export, and other names. The checkboxes in the "Objects to Search" area control which of these pieces of text will be considered. "Automatically Generated" names are those created for you by the system. They can be included in the search but normally are not.
![]() |
4-11-1: Introduction |
![]() |
![]() |
The 3D View is based on Java3D, the Java interface for interactive 3D graphics.
Because not everyone has a full 3D capability on their computer, the 3D facilities are dependent on
these extra installations:
|
To see the 3D view of a layout cell, use the 3D View command (in menu Window / 3D Window). The cell is displayed in 3D, and mouse movements will rotate, pan, or zoom the circuit. Use the left button to rotate, the right button for panning, and the middle one for zooming. When zooming, drag the middle button in one direction to zoom in, and the other direction to zoom out. Standard pan and zoom operations (in menu Window) are also available (see Section 4-4-1 and Section 4-4-2).
Each layer of a node or arc is drawn as a separate object in the 3D view. If you click on a node or arc in a 2D view, all of its layers will be highlighted in the 3D view. Conversely, clicking on any layer of a node or arc in the 3D view will show the entire component in the 2D view.
![]() ![]() | Cell instances will be drawn as bounding boxes if they are unexpanded (top illustration), and will show their contents if expanded (bottom illustration). |
If you are running on Windows and are using MDI mode (multiple document interface) the 3D display may not work properly. See Section 1-4 for instructions on running Electric in SDI mode.
Because Java3D makes use of the graphics hardware on your computer, it may be useful to test that hardware with the Test Hardware command (in menu Window / 3D Window).
In the 3D preferences, the thickness and Z distance (height) of each layer can be controlled as well as the view mode, the Z-axis scale, and use of antialiasing.
On the left side of this dialog is a list of layers in the current technology.
On the right side is a cross sectional view of the chip, showing the relative position of each layer.
You can select a layer by clicking on either side of the dialog.
The currently selected layer is highlighted in the list on the left and shown in red in the right-hand view.
Change the "3D HIGHLIGHTED INSTANCES" entry in the "Color" preferences to change the color used for
highlighting layers in the 3D view and
in the preferences.
The distance of the layer from the wafer bottom and its thickness are the most important values. These values are not only used for the 3D view; they are also used whenever layers are presented in "height" order. Once selected, you can type new values into the "Thickness" and "Distance" fields. | ![]() |
By default, a perspective view is shown. Uncheck "Use Perspective" to see a parallel display. Antialiasing can be turned on by checking "Use Antialiasing". Due to performance issues, antialiasing is not on by default.
The transparency option controls whether you can see through layers, allowing finer control of the display. The transparency factor ranges from 0 (fully opaque: not transparent at all) to 1 (completely transparent: an invisible shape). The transparency mode sets the rasterization technique to use during rendering. Possible values are NONE, BLENDED, FASTEST, NICEST or SCREEN DOOR. The default setting of "NONE" indicates that all objects are opaque. Refer to www.j3d.org for technical details.
Other controls are available in this dialog, for example the initial zoom factor and rotation. If the displayed layers are too thin along the Z axis (compared to their X and Y values), use the "Z Scale" field to make everything thicker.
The 3D view uses one the ambient (background) light and two directional lights. The ambient light is always on, but the directional light can be enabled or disabled with the checkboxes.
The directional lights sit outside of the circuit and point in the given direction. The default directions of (-1, 1, -1) and (1, -1, -1) illuminate the 3D view from the front. Although the lights have a default color of white, this can be changed by editing the "SPECIAL: 3D DIRECTIONAL LIGHT" entry in the "Color" preferences.
Ambient light is the background light that fills a room. It is used to illuminate those areas that are not directly hit by the directional lights. The default color of the ambient light is gray, but this can be changed by editing the "SPECIAL: 3D AMBIENT LIGHT" entry in the "Color" preferences.
If Java3D is not installed, the distance and the thickness can still be controlled. In such a situation, the 3D preferences dialog has much more limited information. | ![]() |
|
|
A 3D display can be animated by creating "key frames" along a time line. Interpolators examine the key frames and smoothly animate the 3D view. There are two types of interpolators: simple and path. Simple interpolators have a start and end frame, varying the view between them linearly. Path interpolators allow multiple key frames to combine into a single smooth animation.
Spline interpolators can be created and controlled with the Capture Frame/Animate command (in menu Window / 3D Window). To animate, you must create a sequence of key frames that define the view changes. Each key frame represents a different 3D view of the scene. | ![]() |
To control the animation, make changes to the display and click "Enter Frame". You can enter as many frames as you want and animate them later. The animated sequence is a "demo" that can be saved to disk and restored later for playback. Use the Animate Sample Cell command (in menu Help / Samples) to see an example of animation.
A QuickTime movie can be created by using the "Create Movie" button. For this option, the JMF plugin must be available (see Section 1-5).
![]() |
4-12-1: Digital Waveform Windows |
![]() |
The digital waveform window looks like the picture below. Note also that there is a side bar with a cell explorer in the window, just like in all windows, but the explorer has a "SIGNALS" section that lists the signals found in the simulation.
The waveform window contains a set of panels, each with a signal name and signal waveform. In each panel, signal names are shown on the left, and their waveform on the right. Between the name and the waveform are two control buttons:
Although the color of the waveforms is usually the same, it can vary with the strength of the signal. To enable such a display, check "Multistate display" in the "Simulators" preferences (in menu File / Preferences..., "Tools" section, "Simulators" tab). To control the actual colors used in multistate display, use the "Colors" preferences (in menu File / Preferences..., "Display" section, "Colors" tab) and set the colors for "WAVEFORM: OFF STRENGTH", "WAVEFORM: NODE (WEAK) STRENGTH", "WAVEFORM: GATE STRENGTH", and "WAVEFORM: POWER STRENGTH".
You can select a signal by selecting either its name or the actual waveform. A selected signal is highlighted, and the selected panel is marked with a bold white line (see the "out" signal). Note that when you click on a signal, the equivalent network in the associated schematic or layout window is also highlighted.
You can rearrange the order of the signals by dragging their names to a new location.
You can add a new panel to the waveform window by double-clicking on its name in the "SIGNALS" area (or by dragging that name to the waveform part on the right). If the layout or schematics cell that produced the simulation is being displayed in another window, and the currently selected network in that window is found in the simulation output, then that output can be added to the waveform window with the Add to Waveform in New Panel command (in menu Edit / Selection).
The order of signals in the waveform window is saved in the original cell so that subsequent simulations will show the same signals.
Two vertical cursors appear in the window, called "main" and "extension" (the extension cursor is dotted). Their time values and their difference are shown at the top of the window. You can click over the cursors and drag them to different time locations. You can also use the "Center" buttons to bring these cursors to the center of the display.
The time axis of the simulation window can be controlled with the appropriate Window menu commands.
Use Zoom Out and Zoom In to scale the time axis by a factor of two.
Use Focus on Highlighted to display the range between the main and extension cursors.
![]() | Besides controlling time with menu commands, you can also use the Pan and Zoom tools of the toolbar to change the view. | ![]() |
The different panels in the waveform window are locked in time: they all show the same range of time,
as shown at the top of the waveform window.
If you click on the "time lock" button at the top of the waveform window
(looks like a lock with the time on it: )
then time is unlocked, and each panel has its own time scale.
Now individual panels can show a different range of time than the rest.
Electric does crossprobing between the waveform window and an edit window with the original circuit. If the original circuit is being displayed, selection in the waveform window is mirrored in that cell. Also, whenever the main time cursor changes, the electrical state of the circuit is shown in that cell. Wires are colored differently according to their high/low/X/Z value in the simulation at that time. If you connect Simulation Probe nodes to any part of the circuit, those nodes light up with the appropriate color instead, which allows better visualization of activity patterns (see Section 7-6-3). You can control the colors used in crossprobing by using the "Colors" preferences (in menu File / Preferences..., "Display" section, "Colors" tab) and setting the colors for "WAVEFORM: CROSSPROBE LOW", "WAVEFORM: CROSSPROBE HIGH", "WAVEFORM: CROSSPROBE UNDEFINED", and "WAVEFORM: CROSSPROBE FLOATING".
For best visualization of the simulation activity, there is a set of VCR buttons to control an animation of the main time cursor. The play rate can be controlled by the "F" and "S" buttons which make it go faster or slower. As the time cursor sweeps across the waveform window, the original circuit can be seen to change levels.
These window functions apply to the digital simulation windows:
When the waveform window displays the output of built-in simulators, you can set stimuli on the signals to affect the simulation. Each stimulus that you set is marked with a large red box at the time of the stimulus (see signals "cc" and "in"). You can select the stimuli by clicking on the red box. A selected stimulus has a green box in it (see the rightmost stimulus on signal "in").
To set stimuli, select either a waveform or the equivalent network in the original schematic or layout. Once selected, use the Set Signal High at Main Time (in menu Tool / Simulation (Built-in)) to make that signal go to "high" at the time indicated by the Main cursor. Use Set Signal Low at Main Time to set the selected signal "low", and use Set Signal Undefined at Main Time to set the selected signal "undefined" (X). Use the Get Information about Selected Signals command to show stimuli and other information on the selected signals.
Besides simple test vectors, the ALS simulator can also set clock patterns on the currently selected signal by using the Set Clock on Selected Signal... command. There are two ways to specify a clock: by frequency (in cycles per second) or period (in seconds). | ![]() |
Note that the clock cycles infinitely, but Electric generates simulation events to fill only the current waveform window. If you want more clock events generated, zoom-out the waveform window before issuing the clock command.
To remove the selected stimulus, use the Clear Selected Stimuli command. To remove all stimuli on a the selected waveforms, use Clear All Stimuli on Selected Signals. To remove all stimuli in the simulation, use Clear All Stimuli.
Once a set of stimuli has been established, you can save it to disk with the Save Stimuli to Disk... command. These stimuli can be restored later with the Restore Stimuli from Disk... command. Each built-in simulator has its own format for saving stimuli.
The "Simulators" preferences (in menu File / Preferences..., "Tools" section, "Simulators" tab), offers some controls for built-in simulators.
At the top of the waveform window, above the signal names, are many useful controls. Those relating to time have already been discussed. Here are the remaining buttons:
The analog waveform window looks like the picture below. Note that there is a side bar with a cell explorer in the window, just like in all windows, but the explorer has a "SIGNALS" section that lists the signals found in the simulation (and optionally a "SWEEPS" section if swept data was found).
The waveform window contains a set of panels, each with one or more signals and waveforms. In a panel, signal names are shown on the left, and their waveform on the right. Above the signal names in each panel are 5 names and controls:
You can rearrange the order of the signals by dragging their names to their desired location. You can change the color of a signal by right-clicking on its name.
You can add a signal to the list by double-clicking on its name in the "SIGNALS" area
(or by dragging that name to the waveform part on the right).
The signal will be added to the highlighted panel (the one with the bold vertical axis).
You can create a new panel, with no signals in it, by clicking on the button in the upper-left of the waveform window
(looks like: a panel-with-waveform icon being dropped down).
If the simulation had sweeps, those values are shown in the cell explorer in the "SWEEPS" area. You can right-click on a sweep and choose to include or exclude it from the display. You can also request that a sweep signal be highlighted. Right-clicking on the "SWEEPS" icon lets you include or exclude all of them.
If the layout or schematics cell that produced the simulation is being displayed in another window, and the currently selected network in that window is found in the simulation output, then that output can be added to the waveform window with the Add to Waveform in New Panel command (in menu Edit / Selection). The command Add to Waveform in Current Panel overlays the signal on top of others in the currently selected waveform panel.
The order of signals in the waveform window is saved in the original cell
so that subsequent simulations will show the same signals.
Two vertical cursors appear in the window, called "main" and "extension" (the extension cursor is dotted). Their time values and their difference are shown at the top of the window. You can click over the cursors and drag them to different time locations. You can also use the "Center" buttons to bring these cursors to the center of the display.
The time axis of the simulation window can be controlled with the appropriate Window menu commands. Use Zoom Out and Zoom In to scale the time axis by a factor of two. Use Focus on Highlighted to display the range between the main and extension cursors.
![]() | Besides controlling time with menu commands, you can also use the Pan and Zoom tools of the toolbar. | ![]() |
The pan tool lets you smoothly shift time when you click and drag. In the zoom tool, you zoom into an area by clicking and dragging out that area. To zoom out, hold the shift key and click in the center of the desired area.
You can control the horizontal and vertical range precisely by double-clicking in the vertical scale area. The dialog lets you type exact values into the ranges. | ![]() |
The different panels in the waveform window are locked in time: they all show the same range of time,
as shown at the top of the waveform window.
If you click on the "time lock" button at the top of the waveform window
(looks like a lock with the time on it: )
then time is unlocked, and each panel has its own time scale.
Now individual panels can show a different range of time than the rest.
A set of VCR buttons is available to animate the main time cursor. The play rate can be controlled by the "F" and "S" buttons which make it go faster or slower. As the time cursor sweeps across the waveform window, the original circuit can be seen to change levels.
These window functions apply to the analog simulation windows:
At the top of the waveform window, above the signal names, are many useful controls. Those relating to time have already been discussed. Here are the remaining buttons:
![]() |
5-1: Introduction to Arcs |
![]() |
The arcs in a circuit are much more than simple connecting wires. They can take many different forms according to the needs of the design environment. In schematics, arcs can be negated, directional, zig-zag, and more. In layout, they can be directional and extended by half of their width. | ![]() |
The most important property of an arc is its ability to remain connected when physical changes are made to the circuit. Constraining properties provide for intelligent circuit layout.
Electric allows you to control how layout changes when the circuit is modified. This is done by placing constraints on the arcs that react to node changes. Electric has a set of four constraints that, although not complete, have been found to be useful in circuit design.
![]() |
5-2-1: Rigid and Fixed-Angle Arcs |
![]() |
The first constraint in Electric is the rigid constraint.
When an arc is made rigid, it cannot change length.
If a node on either end is moved, the other node and the arc move by the same amount.
Besides keeping a constant length, rigid arcs attach in a fixed way to their nodes.
This means that if the node rotates or mirrors, the arc spins about
so that the overall configuration does not change.
Without this rigidity constraint, arcs simply stretch and rotate to keep their connectivity.
The second constraint, which is used only if an arc is not rigid, is the fixed-angle constraint. This constraint forces a wire to remain at a constant angle (usually used to keep horizontal and vertical wires in their Manhattan orientations). For example, if a vertical fixed-angle arc connects two nodes, and the bottom node moves left, then the arc and the top node also move left by the same amount. If that bottom node moves down, the arc simply stretches without affecting the other node. If the bottom node moves down and to the left, the arc both moves and stretches. Rotation of nodes causes no change to fixed-angle arcs unless the arc is connected to an off-center port, in which case a slight translation and stretch may occur. | ![]() |
Most IC layout is done with Manhattan geometry. If you suspect that some of your wires have become skewed, use the Show Nonmanhattan command (in menu Edit / Cleanup Cell).
Slidable arcs may adjust themselves within the port area rather than move. For example, if a node's motion is such that the arc can slide without moving, then no change occurs to the arc or to the other node. Without the slidable constraint, the arc moves to stay connected at the same location within the port. Slidability propagation works both ways, because if an arc moves but can slide within the other node's port, then that node does not move. Note that slidability occurs only for complete motions and not for parts of a motion. If the node moves by 10 and can slide by 1, then it pushes the arc by the full 10 and no sliding occurs. In this case, only motions of 1 or less will slide.
Because ports have area, and because arcs end somewhere inside of that area, the actual ending point can vary considerably. If the arc is at the far side of the port, it may protrude out of the far side of the node, causing unwanted extra geometry. You can shorten an arc so that its endpoint is at the closest side of the port with the Shorten Selected Arcs command (in menu Edit / Cleanup Cell).
This is the constraint that all arcs must stay in their ports, even across hierarchical levels of design. When a node in a cell moves, and has an export on it, all the ports on instances of that cell also change. The constraint system therefore adjusts all arcs connected to those instances, and follows their constraints. If those constraints change nodes with exports in the higher-level cell, then the changes propagate up another level of hierarchy. | ![]() |
This bottom-up propagation of changes guarantees a correctly connected hierarchy, and allows top-down design. Users can create skeleton cells that are mostly empty and contain only exports on unconnected nodes. They can then do high-level design with these skeleton cell instances. Later, when circuitry is placed in the cells, or when layout views are substituted for the skeletons, the constraint system will maintain proper connectivity in all higher levels of hierarchy.
The hierarchical-propagation aspect of the constraint system leaves open the possibility of an overconstrained situation. For example, if two different cell instances are connected to each other with two rigid wires, and one connection point moves, then it is not possible to keep both wires rigid. Electric jogs an arc, converting it into three arcs that zig-zag, to retain the connection. Although connectivity is retained, the geometry may be in the wrong place, causing unexpected changes to the circuit. Users are encouraged to examine the hierarchy to make sure that arbitrary hierarchical changes do not cause undetected damage to the layout. Electric will warn you of any changes which affect undisplayed cells farther up the hierarchy.
![]() |
5-3: Setting Constraints |
![]() |
In order to set slidability (see Section 5-2-2), select a single arc and issue the Object Properties... command (in menu Edit / Properties).
At the bottom of the arc properties dialog, when the "More" button has been pressed, are check boxes that control constraints. This is the only way to affect the slidable constraint (which is not very commonly used). | ![]() |
![]() |
5-4-1: Directionality |
![]() |
![]() | For documentation purposes, it is possible to display a directional arrow on arcs to indicates flow. This property can be changed with the Toggle Directionality command (in menu Edit / Arc). It may also be controlled by the Object Properties... dialog (in menu Edit / Properties). |
The controls in the Object Properties... dialog offer the option of placing the arrow head on either end, both ends, or neither end. This allows arbitrary combinations of arrow heads and bodies to display arbitrarily intricate directionality schemes.
![]() | Arcs in the Schematic technology may be negated, which causes them to have a bubble drawn where they attach to schematic elements. This property can be changed with the Toggle Port Negation command (in menu Edit / Technology Specific). It may also be controlled by the Object Properties... dialog (in menu Edit / Properties). Note that you can select an arc to toggle negation (which leaves the system to guess which end you want to negate) or you can select a node and port (in which case, the arc attached to that port is negated). |
Note that the Object Properties... dialog offers precise control of the negating bubbles, allowing you to specify which ends have the bubbles on them. Negated arcs make no sense in layout technologies and are ignored.
All arcs are drawn so that their geometry extends beyond their endpoints by one-half of their width. This property can be set or reset with the Toggle End Extension of Head and Toggle End Extension of Tail commands (in menu Edit / Arc). It may also be controlled by the Object Properties... dialog (in menu Edit / Properties). | ![]() |
All arcs are named in Electric, so if you don't give it a name, one will be assigned. These names, which typically take the form "object@number" are temporary names, and are distinguished from the names given by the user.
Arc names can be quite complex when applied to busses. The names can be indexed, aggregated, and otherwise be used to describe multiple signals. See Section 6-9-3 for more on bus naming.
![]() | The Curve through Cursor command (in menu Edit / Arc) requests that the currently highlighted arc curve in such a way that it passes through the location of the cursor. The Curve about Cursor command requests that the currently highlighted arc curve between its endpoints such that the center of curvature is at the location of the cursor. After issuing these commands, click and drag to see how the arc will curve. |
The Remove Curvature command makes the arc straight.
![]() |
5-5: Default Arc Properties |
![]() |
The top part of the dialog allows you to set defaults for specific types of arcs in the current technology. You select the "Arc Type" and then set defaults for it (such as the "Default width").
The "Placement angle" is the granularity for running this type of arc (in degrees). A value of 90 lets arcs run at 0, 90, 180, or 270 degrees: manhattan geometry. A value of 45 lets it run at any of 8 angles (useful for schematics). A value of 0 lets it run at any angle (used in artwork).
The "Pin" is the node that gets used for connecting two of these arcs. It is typically a "Pin" node (see Section 7-1-1). If changed to a node with geometry (such as a contact node) then these contacts will be placed at the bends of this arc.
The checkboxes in the "Default State" section have these meanings:
| ![]() |
The bottom portion of the dialog has controls for all arcs.
![]() |
6-1: Making Copies |
![]() |
The Duplicate command (in menu Edit) makes a copy of the selected nodes and arcs. After issuing this command, you can move the cursor to any location and click to place the copy. While moving the cursor, an outline of the duplicated objects is shown (as well as the amount of motion).
If you have disabled "Move after Duplicate" (in the "New Nodes" preferences, in menu File / Preferences..., "General" section, "New Nodes" tab) then the duplicated objects are placed immediately without dragging.
If any of the nodes have exports on them, they are not duplicated (unless "Duplicate/Array/Paste copies exports" is set in "New Nodes" tab).
The Duplicate command forces newly created nodes and arcs to have unique names. This means that if any nodes or arcs are named (using the Object Properties... command, in menu Edit / Properties) and then duplicated, the new ones will have different names (specifically, the old names with numbers appended or modified).
Another way to make copies of nodes and arcs is with the cut-and-paste commands. The Copy and Cut commands (in menu Edit) copy the currently selected nodes and arcs to a special buffer. Cut also removes the objects after copying them. The Paste command then copies the objects from the special buffer to the display. After issuing this command, an outline of the pasted objects attaches to the cursor. When you click, the objects are placed at that location. You can right-click during the paste drag to affect the location, and to abort the paste.
Note that if you copy a node or arc and then select another before pasting, then the copied object will replace the selected object (changing its type and other properties, similar to the Change... command, in menu Edit, see Section 6-6). If you want the Paste command to make a second copy, be sure that nothing is selected when you issue the command. Thus, duplicating an object cannot be done by issuing a Copy and then a Paste. You must do a Copy, then deselect the object, then do a Paste.
![]() |
6-2: Creation Defaults |
![]() |
To do this, use the "New Nodes" preferences (in menu File / Preferences..., "General" section, "New Nodes" tab). The top part of the dialog controls primitive nodes. You can change the default size of any primitive node in the current technology by choosing the node and changing the values. | ![]() |
The middle section of the dialog controls cells. The check box "Check cell dates during editing" requests that date information be used to ensure a proper circuit building sequence. When this box is checked, warning messages will be issued when editing a cell that has more recent subcell instances. Electric tracks cell creation and revision dates, and this information can be displayed with the Describe this Cell command and others in menu Cell / Cell Info (see Section 3-7-1).
The check box "Switch technology to match current cell" requests that the current technology automatically change whenever the current cell changes, so that the two match.
The check box "Place Cell-Center in new cells" requests that all newly created cells have a Cell-Center node placed at the origin (see Section 3-3 for more on Cell centers).
The bottom part of the dialog applies to all nodes.
The check box "Disallow modification of locked primitives" requests that all lockable primitive node instances be anchored. Once locked, these nodes cannot be created, deleted, or modified in any way. Typically, only primitives in "array" technologies are lockable (such as the FPGA technology, see Section 7-6-2), presuming that these components will be used to define the fixed circuitry that is then customized. Design of the fixed circuitry is done with this lock off, and then the customization phase is done with this lock on.
The check box "Move after Duplicate" allows duplicated objects to be positioned interactively. This is the default condition. However, if this is unchecked, then the Duplicate command (in menu Edit) will place a copy automatically, without allowing the new location to be specified by the cursor.
The check box "Duplicate/Array/Paste copies exports" requests that these node-copying operations also copy their exports. This includes the Duplicate, Array, and Paste commands (in menu Edit) . See Section 6-4 for more on arrays.
The check box "Extract copies exports" requests that extraction of cell instances also copy the exports. Extraction is done with the Extract Cell Instance command (in menu Cell). See Section 3-8 for more on extraction.
![]() |
6-3: Preferences |
![]() |
The Preferences... command (in menu File) contains dozens of panels for controling preferences. You can also see the preferences dialog by using the preferences icon from the tool bar. | ![]() |
The left side of the Preferences dialog is a tree-structured list of all of the different preference panels. The right side is the actual preference panel, which changes according to the panel requested. Below the list of panels is a "Help" button which takes you to the proper manual page which explains that panel.
Preferences are stored permanently on your computer and are remembered each time you run Electric. The actual location of this information varies with each operating system.
You can also export your preferences with the Preferences... command (in menu File / Export) which will write an XML file with preference information. This XML file can be read back into Electric's preferences with the Preferences... command (in menu File / Import).
There are two types of preferences: appearance and meaning. Appearance preferences affect only the way Electric appears when run, and do not affect the actual circuitry. Meaning preferences affect the interpretation of the data, and therefore their settings are critical to your design.
Electric stores meaning preferences in every library file so that, when read back in, the preferences can be reconciled with current settings. When a library is read that has different meaning preferences, this dialog appears:
You must choose whether you want to use the preference value from the library (recommended) or the current setting. This can be done on an individual-preference basis, or for all preferences that conflict.
![]() |
6-4: Making Arrays |
![]() |
The Array... command (in menu Edit) takes the currently highlighted objects and replicates them many times. You specify the number of replications in the X and Y directions and the geometry is arrayed.
Arrays are generated by X (row) with Y (column), following a raster scan order. If you request that alternate rows or columns be flipped, then they are mirrored in the direction of repetition. If you request that alternate rows or columns be staggered, then each element is offset by an alternating amount. If you request that the rows or columns be centered, then the original circuitry will be placed in the middle of the array instead of the corner. If the X or Y values are negative, then the array is laid out backwards (replications are placed in the reverse direction).
There are four ways to specify spacing: edge overlap, centerline distance, characteristic spacing, or measured distance. The edge overlap amounts indicate the amount by which the rows and columns will be squeezed together (zero overlap causes the each arrayed copy to touch the next one, negative overlap can be specified to spread the objects apart). Centerline distance is the distance between object centers, and defaults to the size of the selected objects (which causes the copies to touch). Characteristic spacing is an amount that is set for specific cells (see Section 3-7-3). If a cell with a characteristic spacing is arrayed, that value can be used. Finally, the last measured distance can be used to determine the array spacing (for more on measuring, see Section 4-7-4).
The "Linear diagonal array" check box indicates that the array is linear (one of the repeat factors must be 1) but that both spacing rules will be applied. This therefore creates a single line that runs diagonally.
The "Generate array indices" check box requests that the array entries be drawn with index information. When this is checked, array entries are labeled with the index of each entry. The original copy is labeled "0-0" and the copy to its right is labeled "1-0". These names are simply visual tags that have no bearing on the contents (use the Object Properties... command, in menu Edit / Properties, to set or remove these names).
The "Only place entries that are DRC correct" check box requests that array entries only be placed where they do not create design-rule violations. This option is only available if a single node is being arrayed. After the array is created, the design-rule checker is run on each entry, and if it causes an error, it is removed.
The "Transpose placement ordering" check box requests that array placement go by column instead of by row. This is useful if the arraying includes names which are being auto-incremented in the array. By transposing the order of arraying, the names will run in the orthogonal direction.
![]() |
6-5: Spreading Circuitry |
![]() |
With the Spread... command, the highlighted node is a focal point about which objects move. A dialog is presented in which an amount and a direction (up, down, left, or right) are specified. An infinite line is passed through the highlighted node's center and everything above, below, to the left of, or to the right of the line is moved by the specified amount. | ![]() |
Negative spread distances compact the circuit.
![]() |
6-6: Replacing Circuitry |
![]() |
The Change... command (in menu Edit) removes the currently highlighted node or arc and replaces it with a new one of a different type. This same effect can be had by copying one object and then pasting it onto another (see Section 6-1). A dialog is presented in which the possible replacements are shown. For node changing, you can choose to show primitives from the current technology, cells from the current library, or both. | ![]() |
When replacing an arc, the existing nodes on either end must be able to reconnect to the new type of arc. If "Change nodes with arcs" is checked, nodes will be changed to allow the new type of arc to remain connected.
When replacing a node, the existing arcs on it must be able to reconnect properly to the new node. However, the sizes of the replaced object can be different, and the layout will be adjusted. Electric determines which ports on the replaced node to use by examining the port names and locations. If the ports are aligned correctly but not named the same, this matching will fail. Check "Ignore port names" to disable name matching and use only position information. If the new node is missing essential ports, such that existing wires cannot be reconnected, then the change will fail (unless "Allow missing ports" is checked).
Besides replacing the currently highlighted node or arc ("Change selected ones only"), it is also possible to specify replacement of many other objects.
This is a modeless dialog: it can remain up while other editing is being done. Click "Done" to dismiss it, and "Apply" to make a change.
Note that some Schematic nodes use parameters to further describe them. For example, an electrolytic capacitor is really just a capacitor with the "electrolytic" parameter on it. Therefore, you can change a node into a capacitor, but not an electrolytic capacitor, because it is not in the list. To change a capacitor into an electrolytic capacitor, paste an electrolytic capacitor onto it. Besides capacitors, parameters can be found on diodes, transistors, sources, and two-ports (the four-connection primitives such as VCCS).
![]() |
6-7: Undo Control |
![]() |
The Undo command (in menu Edit) reverses the last change made (this includes any changes that may have been made by other tools). Multiple uses of the Undo command continue to undo further back. The Redo command redoes changes, up to the most recent change made.
You can also use the undo (counterclockwise) and redo (clockwise) icons from the tool bar. | ![]() |
Electric stores only the last 40 changes, so anything older than that cannot be undone. To increase the number of changes that are saved, use the "General" preferences (in menu File / Preferences..., "General" section, "General" tab), and change the "Maximum undo history" field. To see a history of changes that were made, use the Show Undo List command (in menu Edit / Info).
In Electric, almost every command is undoable, but there are some exceptions. Commands that write disk files are not undoable, because Electric would not be so presumptuous as to delete a disk file. Also commands that make vast changes (such as library deletion) are not undoable.
Another useful command in for controlling changes being made is Repeat Last Action (in menu Edit). This repeats the last command, but only works for commands that can sensibly be repeated.
![]() |
6-8-1: Understanding Text |
![]() |
Certain types of text are not easily selectable. This is a feature that prevents accidental selection of unwanted text. For such hard-to-select text, the only way to select them is to use special select mode (see section 2-1-5). By default, the name of an unexpanded cell instance is hard-to-select. However, you can also request that names on nodes and arcs (annotation text) also be difficult to select by unchecking "Easy selection of annotation text" in the "Selection" preferences (in menu File / Preferences..., "General" section, "Selection" tab).
All text is attached to its node or arc at an anchor-point. This is the one point on the text that never moves, regardless of the size of the text. The highlighting of selected text varies according to the anchor-point. Typically, the highlighting consists of an "X" through the text. This indicates that the anchor-point is in the center. If a "U" is drawn in any of four orientations, it indicates that the anchor-point is on the side and that the text grows out of the opened end. If an "L" is drawn in any of four orientations, it indicates that the anchor-point is in a corner. | ![]() |
Finally, the text may be drawn with an "X" but also have four lines that indicate a box at the object edge. This is centered text that clips to the size of its attached object (it is boxed).
![]() | Note that text can be moved away from its attached node or arc. If this has been done, then selection of the text will also indicate the attached component by drawing a dashed line to it. |
To change text, double-click on it and type new values. To change other aspects of selected text, and use the Object Properties... command (in menu Edit / Properties). This dialog allows modification of the text, size, font, style, anchor-point, rotation, color, and even the offset of the anchor-point from the attached node or arc. Note that the offset is always relative to the center of the attached object. The size of text can be absolute (given in "points") or relative (given in units). The font of the text can be the default font or any font installed on your system. The style of text can be any combination of Italic, Bold, or Underline. Text rotation can be in 90-degree increments only. You can set the units to any electrical type (capacitance, resistance, etc.) See section Section 7-2-2 for more on these units. | ![]() |
The "Code" option allows the text to be code in an interpretive language, in which case, the evaluation of that code is displayed. You can choose to show the text value, the name of the piece of text, or both.
If the text contains more than 1 line, then you must check "Multi-Line Text" in order to edit it. You may then have to stretch the dialog in order to have a larger field for editing the text. The "Highlight Owner" button highlights the node or arc on which the text is attached . The checkbox "Invisible outside cell" requests that the text not be drawn when an instance of the cell is examined.
![]() | The Change Text Size... command (in menu Edit / Text) allows you to change the size, face, and style of any text object. You can choose which of the 6 classes of text you wish to change, and you can choose whether to make the changes only on selected objects, in the current cell, in all cells of a particular view, or everywhere. |
Below the "Default Text Style" section is a popup that sets the default font for Electric. Below that is a setting for the "Global text scale". Normally, all text is drawn at 100% of its stated size. However, you can globally scale all text by typing a value other than 100 into this field. You can also use the Increase All Text Size and Decrease All Text Size commands (in menu Edit / Text) to change this value, and alter the size of all displayed text.
The bottom part of the dialog controls "smart placement" of text, which adjusts the grab point according to the environment of the text. This currently applies only to export names, which are placed relative to the arc connecting to the exported node. For example, if a node on the left end of a wire has an export, and the "Horizontal" placement is set to "Inside", then the export text will attach on the left side, causing the label to appear inside of the wire. | ![]() |
Attributes can be placed on these objects (selected at the top):
Just below the name and value fields are a set of popups that control the attribute. The "Code" popup determines whether the attribute is code or pure data. This can be changed to one of the interpretive languages in Electric. When this happens, the attribute value is treated as code that is sent to that interpreter. Then, the true value of the attribute is the evaluation of that code. For example, if the value of an attribute is "3+5" and the attribute is set to be Java code, then the Java interpreter will be invoked, and the attribute will actually be "8".
You can change the type of unit by using the "Units" popup (choices are capacitance, resistance, inductance, current, voltage, or distance). See Section 7-2-2 for more on these units.
You can control the way that an attribute is displayed in the circuit by selecting the appropriate entry in the "Show:" popup. You can request that various combinations of the attribute's name and value be displayed.
The bottom part of the dialog affects the appearance of the attribute, and is only relevant if the attribute is being shown. The size of the text can be specified in relative or absolute units. The anchor-point of the text can be set. The X and Y offset of the anchor-point from the attached object can be specified. The font of the text can be chosen. The style of the text can be any combination of Italic, Bold, or Underline. You can specify the rotation of the text, in 90-degree increments. You can even give the text a color. The "Invisible outside cell" requests that the attribute not be drawn when viewed farther up the hierarchy.
The "Done" button terminates this dialog.
Note that there is no "Cancel" button: this dialog makes changes as they are entered.
Attributes that are placed on cells or exports get inherited when the cell is instantiated. Each of these attributes is created on the instantiated node and port. It is often desirable for each inherited attribute to have unique names. If the value of a cell or export attribute has "++" in it, then the number before it will be incremented after inheritance. Similarly, a "--" indicates that the number be decremented after inheritance. This allows an inherited attribute to be unique with each inheritance.
When there are too many visible attributes, the display can become cluttered. Use the "Layers" tab of the sidebar to control the text, (see Section 4-5 for more). Attributes on nodes are controlled by the "Node Text" checkbox; those on arcs with the "Arc Text" checkbox, etc.
One example of the use of cell parameters is in the Spice primitives, where user-defined values (such as voltage) are communicated into the icon for generation in the Spice deck (see Section 9-4-3).
Another use of cell parameters is to parameterize the size of a transistor in a schematic (or to parameterize the scalable layout transistors in the MOSIS CMOS technology, see Section 7-4-2) The transistor width and length can be defined in terms of the parameter value, allowing a single cell to take on many different forms. By combining these parameters with the interpretive language facility, an arbitrary mathematical expression can be placed on the transistor which combines parameter values to form the exact transistor size .
Inside of the cell, the parameter is shown with its name and default value. To see the actual value from up the hierarchy, create a Java expression with the value "@PNAME" where PNAME is the parameter name. For example, if a cell has an attribute called "heat", you might place a piece of Annotation Text (with the "Annotation Text" command under the "Misc" entry in the component menu) and name it "@heat". Make sure to set its Code to Java. When first defined, the parameter has no actual value, and so appears as "heat not found" . If an instance is created and its "heat" attribute is set to 7, then descending into that cell will show "7".
If a parameter is added to a cell, existing instances of that cell may not get properly updated.
To do this, use the Update Attributes Inheritance on Node command (in menu Edit / Properties).
To do this everywhere, use the Update Attributes Inheritance all Libraries command.
Parameters on cells are not tied to any node or arc. Instead, they float freely inside of the cell. You can select the text and drag it to any location in the cell.
Parameters on instances of cells are placed at the same location as they appear inside of the cell. In schematics, the location of a parameter on an icon is determined by the location of that parameter on the sample icon, inside of the schematic cell.
If you do not wish to see a parameter's text on any instance, select the parameter text inside of the cell, use the Object Properties... command (in menu Edit / Properties), and check "Invisible outside cell".
You can disable the display of parameters on cell instances by selecting them and using the Hide All Attributes on Node command (in menu Edit / Properties). You can force all parameters to be displayed on a cell instance by using the See All Attributes on Node command. To restore default parameter visibility on a cell instance, use the Default Attribute Visibility command.
![]() |
6-9-1: Introduction to Networks |
![]() |
Whenever a port on a node is selected, the highlighting indicates the entire network that is connected to that port. Another way to see an entire network is to use the Show Network command (in menu Tool / Network). This will highlight all arcs on the currently selected networks. Repeated use of this command causes the network to be highlighted at successively lower levels of the hierarchy.
If the design is very dense, you can select one or more networks by name with the Select Object... command (in menu Edit / Selection).
![]() |
The Resistor can be treated as a connecting or nonconnecting node.
By default, it does not connect the networks on its two ends,
so identification of the extent of a network ends at the resistor.
To ignore resistors and treat them as wires,
use the "Network" preferences (in menu File / Preferences..., "Tools" section, "Network" tab),
and check "Ignore Resistors".
Then highlighted networks will pass through them.
See section Section 7-5-1 for more on resistors.
The other controls in the "Network" Preferences are discussed elsewhere. For an explanation of "Default bus order", see Section 6-9-3). For an explanation of the entries in the "Node Extraction" section, see Section 9-10-2). |
There are many commands in menu Tool / Network that can be used to get information about the networks in a cell:
Two phenomena can occur in network naming: a network can be multiply named, and it can span disjoint circuitry. A network has multiple names when two or more connected arcs or exports are named with different names. For example, if you make an export on a contact node and call it "clock", then you select an arc connected to that contact node and name it "sig", the circuitry will be on the network "clock/sig." Thus, both names now apply to the same network.
The other phenomenon of network naming is that a single network can include unconnected parts of the circuit. This happens when arcs in unconnected parts of the circuit are given the same name. This causes the two arcs to be implicitly joined into one network. Because this network naming phenomena is most commonly used in schematics, the unification of like-named networks only happens in cells with the "schematic" view.
When a bus is unnamed, the system determines its width from the ports that it connects. Some tools (such as simulation netlisters) need to name everything, and so use automatically-generated names. When this happens, the system must choose whether to number the bus ascending or descending. To resolve this issue, use the "Network" preferences (in menu File / Preferences..., "Tools" section, "Network" tab), and choose "Ascending" or "Descending".
Individual wires that connect to a bus must be named with names from that bus. As an aid in obtaining individual signals from a bus, the Rip Bus command (in menu Edit / Arc) will automatically create such wires for the selected bus arc.
Besides using array names on busses, you can also give array names to schematic nodes. Netlisters will create multiple copies of that node, named with the individual elements of the array.
All supply networks defined with the Power and Ground nodes of the Schematic technology are combined into one network. This means, for example, that two arcs, each connected to a separate Ground node, appear on the same network regardless of their actual connectivity in the circuit.
As a debugging aid for power and ground networks, the command Show Power and Ground (in menu Tool / Network) shows the entire power and ground network. The Validate Power and Ground command checks all power and ground networks in the circuit. Any power or ground networks that are named according to the prefixes listed above must have the proper characteristics. If, for example, a power network is called "gnd007", then it will be flagged by this command.
In schematics, however, it is often the case that a signal is used commonly without explicitly being wired or exported. Examples of such signals are power, ground, clocks, etc. The power and ground signals can be established in any schematic with the use of the Power and Ground nodes. To create another such signal, use the Global node of the schematics technology (see Section 7-5-1).
The Global node is diamond-shaped, and it has a name and characteristic similar to exports (input, output, etc.) All signals with the same global name are considered to be connected when netlisting occurs. Thus, the Global symbol can be used to route clock signals, as well as to define multiple power and ground rails. Note that with multiple power and ground rails, only one of them is the true "power and ground" as defined by the Power and Ground symbols. All others, declared with Global nodes, are not true power and ground signals, but are simply globals.
It is sometimes the case that the designer wishes to isolate a global signal and wire it differently. For example, a schematic cell may be defined with power and ground symbols, connecting it to the global power and ground. But a particular instance of the schematic may need to be wired to alternate power and ground rails, for example "dirty power". Another example of rewiring happens when you want to test a specific instance of a cell, and you need to connect its globals differently for the purposes of simulation.
The solution is to place a "Global Partition" node inside of the schematic (see Section 7-5-1). This symbol acts like an "offpage" symbol: it is wired to something inside of the cell (a global signal) and it is also exported to the outside world. | ![]() |
In this example, the schematic has power and ground signals, but the power signal is also connected to a Global Partition node and exported (as "vddR"). The icon has an extra connection for this power tap. In normal use, the extra connections created by the Global Partition nodes do not need to be wired up, because they connect to globals, and their connectivity is understood. If, however, the extra exports are wired, it means that the signal inside of the cell is disconnected from the global, and connected instead to that wire.
![]() | In the example here, two "invR" icons are placed, but one of them has its "vddR" connection wired (to a different power source). The subcircuit for the rightmost icon will not use the global power signal, but will instead use the attached signal, "vddInv". |
![]() |
6-10-1: Introduction to Outlines |
![]() |
For some primitive nodes, it is not enough to rotate, mirror, and scale.
These primitives can to be augmented with an outline,
which is a polygonal description.
There are quite a few primitive nodes that make use of outline information. The MOS transistors use the outline to define the gate path in serpentine configurations (see Section 7-4-1). The Artwork technology has nodes that use outline information: Opened-Solid-Polygon, Opened-Dotted-Polygon, Opened-Dashed-Polygon, Opened-Thicker-Polygon, Closed-Polygon, Filled-Polygon, and Spline (see Section 7-6-1). For arbitrary shapes on arbitrary layers, use the pure-layer nodes in the IC layout technologies. The pure-layer nodes are found under the "Pure" entry in the component menu. For example, the node called "Metal-1-Node" in the CMOS technologies looks like a rectangle of the Metal-1, until you add outline information. With an outline, this node can take any shape. | ![]() |
Because pure-layer nodes are unusual, it is useful to be able to identify them. Use the Show Pure Layer Nodes command (in menu Edit / Cleanup Cell) to highlight all of them in the current cell.
To manipulate outline information on the currently highlighted node, use "Outline Edit" mode (click on the icon in the tool bar or use the Toggle Outline Edit command, in menu Edit / Modes / Edit). | ![]() |
In outline edit mode, the left button is used to select and move a point on the outline, and the right button adds a new point after the selected one.
Besides selecting points with the mouse, you can also step through the points of the outline with the "." key (next outline point) and "," key (previous outline point). These keys are under the ">" and "<" keys, so you can think of them as the "next point" (>) and "previous point" (<) commands.
The Erase command (in menu Edit) deletes the current outline point (so does the Delete key).
When done editing the outline, switch to standard selection mode (the Click/Zoom/Wire command, in menu Edit / Modes / Edit).
![]() |
To generate a doughnut shaped outline, use the "Annular Ring..." command under the "Misc" entry
in the component menu.
This dialog prompts for a layer to use and an inner and outer radius for the annulus.
By default, it is made as a full circle (360 degrees), but this can also be changed.
Finally, the number of line segments used in the construction can be set,
allowing for smoother or coarser shapes.
![]() |
To generate text-shaped outlines,
use the "Layout Text..." command under the "Misc" entry in the component menu.
This dialog prompts for text and a layer to use as well as the size, scale, font, and style.
A nonzero dot separation causes each pixel of the text to be placed separately (some design rules need this).
![]() | ![]() |
![]() |
6-11: Interpretive Languages |
![]() |
The Bean Shell is not part of the default Electric distribution. You must add it as a "plug in" (see Section 1-5 for more on plug-ins).
To run a script, use the Run Java Bean Shell Script command (in menu Tool / Languages). Here is an example script that searches the current cell for exports starting with "a".
import com.sun.electric.database.hierarchy.Cell; import com.sun.electric.tool.user.ui.WindowFrame; import java.util.List; import java.util.ArrayList; import java.util.Iterator; // read library with test setup Cell lay = WindowFrame.getCurrentCell(); // find all exports com.sun.electric.database.hierarchy.Export e; List aList = new ArrayList(); for(Iterator it = lay.getPorts(); it.hasNext(); ) { e = (com.sun.electric.database.hierarchy.Export)it.next(); if (e.getName().startsWith("a")) aList.add(e); } String aOut = "Exports that start with 'a':"; for(Iterator it = aList.iterator(); it.hasNext(); ) { e = (com.sun.electric.database.hierarchy.Export)it.next(); aOut += " " + e.getName(); } System.out.println(aOut); |
Notice that Electric's "Export" object must be a fully-qualified name, because the name "Export" is used for other reasons in the Bean Shell.
For more information about accessing the interals of Electric, read the Javadoc in the source code.
![]() |
6-12: Project Management |
![]() |
The project management system uses the full power of cells to accomplish its task. It handles design history by creating a new version of a cell each time it is checked out of the repository. The user's library contains only the most recent version of each cell, taken from the repository. When a user updates their library from the repository, newer versions are brought in and substituted for older versions. Unless the user specifically asks for an older version, it is removed from their library.
Because the project management system uses versions to manage design progress, users are discouraged from managing versions explicitly. Thus, the command New Version of Current Cell (in menu Cell) is not allowed. Also, it is not appropriate for a user to use two different versions of a cell explicitly, because they are considered to be part of a single cell's history.
All commands to the project management system can be found under the Project Management command (in menu File). Subcommands exist there for checking cells in and out, updating local libraries from the repository, and more. Many project management functions are also available in context menus in the cell explorer.
The first step needed to use the project management system is to choose a location for the repository. This must be a shared location that each user can access (read and write). Use the "Project Management" preferences, in menu File / Preferences..., "General" section, "Project Management" tab. Each user must do this and set the same location so that they can share the repository. | ![]() |
After the repository has been set, libraries can be entered into it. Use the Add Current Library To Repository command to place your library in the repository. Note that a library that has been entered into the repository is also tagged with information about the repository location, as well as the state of the cells (checked-in or checked-out). Therefore, you should save your library after entering it into the repository.
Other users can obtain a copy of your library directly from the repository by using the Get Library From Repository... command.
Individual users can now begin to work on the library. Before checking cells out of a library, it is necessary to create a "user" account in the project management system. The "Project Management" preferences shows a list of users. Although each user must "login" to the project management system with their own password, Electric remembers the logged-in user between sessions, so it is not necessary to do this more than once. Adding new users can be done in the "Administration" section of the dialog. Note that to add or delete users, the administrator must first click "Authorize..." and provide the appropriate password. This password is provided elsewhere in the manual.
When a cell is not checked out, you cannot make changes to it. Any change is immediately undone by the project management system. This means that a change which affects unchecked-out cells, higher up the hierarchy, will also be disallowed.
To check-out the current cell, use the Check Out This Cell command. If there are related cells (hierarchically above or below this) that are already checked-out to other users, you will be given warnings about potential conflicts that may arise.
To check the current cell back in, use the Check In This Cell... command. You will be prompted for a documentation message about the change. No further changes will be allowed to the cell. Note that when checking-in a cell, other cells above and below this in the hierarchy will also be checked-in. This is because changes affect other cells in the hierarchy, and so consistent pieces of the hierarchy must be updated at the same time.
The cell explorer shows the state of cells that are under project management control (see Section 4-8). Locks are drawn over cells to indicate their state (checked-in, checked-out to you, or checked-out to others). You can also access many of the project management commands by selecting cells in the explorer and using context menu commands. | ![]() |
To update your library so that it contains the most recent version of every cell, use the Update command. This will retrieve the newest version of every cell in every library that is being managed. You will be given a list of cells that were replaced.
If, after a cell has been checked-out, you change your mind and do not wish to make changes, use the Cancel Check-Out command (or use the "Cancel Check-Out" context menu when clicking on a cell name in the cell explorer). This will destroy any changes made to the cell since it was checked-out and revert the cell to its state when it was checked-in.
If, in the course of design, a new cell is created, it must be added to the repository so that others can share it. Use the Add This Cell command to include the cell in the repository. Similarly, if a cell is to be deleted, use the Remove This Cell command to delete it from the repository.
To examine the history of changes to a cell, use the Show History of This Cell... command (or use the "Show History of This Cell..." context menu when clicking on a cell name in the cell explorer). Besides showing the history of changes, you can use this dialog to retrieve an earlier version of the cell.
The project management system makes use of version information on all cells to control cell changes. When a cell is checked-out, a new version is made in your local library, and the old version is deleted. All instances of the old version are switched to the new version. The old version remains in the repository. When the cell is checked-in, that new version also goes into the repository. When updates are done, newer versions are obtained from the repository, and appropriate substitutions are performed.
It is assumed that anyone who has read all the way to the end of this manual page must be quite serious about the project management system. Such a person is probably an administrator, and therefore deserves to know what the administration password is for adding and deleting users. The password is just the letter "e". For increased security, edit the code and change this to something more secure.
![]() |
6-12: Emergencies |
![]() |
If a thread crashes and leaves a Job running, then you will not be able to issue other commands, because their Jobs will be queued behind the stuck one (see Section 4-8 for more viewing Jobs). Even the Quit command is a job, and so it cannot run. To solve this problem, use the Force Quit (and Save) command (in menu File).
If you suspect that the database is corrupt, use the subcommands of the Check Libraries command (in menu File). The Check command examines the database but does not fix errors. The Repair command checks and repairs the database (if it can).
The networks may also need to be renumbered. Do this with Redo Network Numbering command (in menu Tool / Network).
![]() |
7-1-1: Technologies |
![]() |
Each technology consists of a set of primitive nodes and arcs. These, in turn, are constructed from one or more layers. Each technology also includes information necessary to do design, such as design rules, connectivity rules, simulation information, etc.
The primitive nodes in a technology come in three styles: pins, components, and pure-layer nodes. The pins are used to join arcs, so there is one pin for every arc in the technology. The components are the basic nodes used in design: contacts, transistors, etc. Finally, the pure-layer nodes are used for geometric manipulation (see Section 6-10-1). There is one pure-layer node for every layer in the technology.
The component menu in the side bar (on the left side of the editing window) shows arcs on the left (the menu entries with red border), pin nodes in the center column (these appear as boxes with a cross inside), and components on the right (the more complex layer combinations). The pure-layer nodes are available under the entry labeled "Pure".
Electric has a "sample" library built into it that illustrates many features. To access it, use the Load Library command (in menu Help / Samples). The table below lists the cells in that library which illustrate different technologies:
Technology | Description | Sample Cell |
mocmos | MOSIS CMOS rules | tech-MOSISCMOS{lay} |
bipolar | Simple bipolar technology | tech-Bipolar{lay} |
schematics | Digital schematics layout | tech-SchematicsDigital{sch} |
schematics | Analog schematics layout | tech-SchematicsAnalog{sch} |
artwork | Graphical design | tech-Artwork |
pcb | Printed Circuit Boards | tech-PCB{sch} |
nmos | n-Channel MOS rules | tech-nMOS{lay} |
rcmos | Round CMOS rules | tech-RoundCMOS{lay} |
efido | Digital Filter technology | tech-DigitalFilter |
gem | Temporal Logic specification | tech-Gem |
You can change the current technology by selecting it from the popup at the top of the side bar (either the "Components" or "Layers" tab). Electric automatically switches the current technology to match the cell being edited. If there are multiple cells being edited from different technologies, this switching can become annoying. To disable automatic technology switching, use the "New Nodes" preferences (in menu File / Preferences..., "General" section, "New Nodes" tab), and uncheck "Switch technology to match current cell".
To see a list of primitive nodes and arcs in the current technology, use the Describe this Technology command (in menu Edit / Technology Specific). To see a detailled description of the current technology, use the Document Current Technology command.
The "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab) lets you control many general and specific technology settings.
You can change the default technology with the popup in the upper-left of this dialog. This default technology is the used when Electric first begins. It is also used when reading old libraries that are missing some technology information.
Besides remembering a startup technology, Electric also remembers a default "layout" technology. This is a technology with real geometry (an integrated circuit technology, not a schematics or artwork technology) The default layout technology is used to give further information about schematics components . It is listed in the "Schematics" section under "Use scale values from this technology".
Some technologies have settable options that further customize them. The "Technology" preferences dialog lets you control these options. More information about this dialog is available from the individual technology sections on MOSIS CMOS (Section 7-4-2), Schematics (Section 7-5-1 and Section 3-11-2), and Artwork (Section 7-6-1).
![]() |
7-2-1: Scale |
![]() |
For example, if the scale for the MOSIS CMOS ("mocmos") technology is 200 nanometers, then a 2 x 3 transistor is actually 400 x 600 nanometers (or 0.4 x 0.6 microns).
To set the scale, use the "Scale" preferences (in menu File / Preferences..., "Technology" section, "Scale" tab).
Scale only applies to integrated-circuit layout technologies. There is no scale for Schematics, Artwork, and other nonlayout technologies.
![]() | Although distances are described in dimensionless units, they must be expressed with real units when converted to the real world. You can choose which unit should be used with the "Units" preferences (in menu File / Preferences..., "Technology" section, "Units" tab). |
Much of this dialog is currently unavailable, because the system does not use this information.
![]() |
7-3-1: I/O Specifications |
![]() |
To properly control translation, use the many preferences dialogs for the different file types (in menu File / Preferences..., "I/O" section).
Unfortunately, many of these formats are pure geometry with no information about the circuit connections. When read, they appear as pure-layer nodes. This means that transistors, contacts, and other multi-layer nodes are not constructed properly. Although the cell appears visually correct, and can be used to export the same type of file, it cannot be analyzed at a circuit level. The node extractor can be used to convert these pure-layer nodes to true Electric components (see Section 9-10-2).
The next few sections describe control of different I/O formats.
This dialog controls the conversion between layers in Electric and layers in the CIF file. By clicking on an Electric layer, you can type a new CIF layer name into the dialog. | ![]() |
By default, CIF output writes the entire hierarchy below the current cell. If you check the "Output Mimics Display" item, cell instances that are unexpanded will be represented as an outline in the CIF file. This is useful when the CIF output is intended for hardcopy display, and only the screen contents is desired.
Another option is whether or not to merge adjoining geometry. This is an issue because of the duplication and overlap that occurs wherever arcs and nodes meet. The default action is to write each node and arc individually. This makes the file larger because of redundant box information, however it is faster to generate and uses simpler constructs. If you check the "Output Merges Boxes" item, all connecting regions on the same layer are merged into one complex polygon. This requires more processing, produces a smaller file, and generates more complex constructs.
Another option is whether or not to instantiate the circuit in the CIF. By default, the currently displayed cell becomes the top level of the CIF file, and is instantiated at the end of the CIF. This causes the CIF file to display the current cell. If the CIF file is to be used as a library, with no current cell, then uncheck the "Output Instantiates Top Level" checkbox, and there will be no invocation of the current cell.
When reading CIF files, the CIF "wire" statements are assumed to have rounded geometry at the ends and corners. If you check the "Input Squares Wires" item, CIF input assumes that wire ends are square and extend by half of their width.
Be advised that the CIF format has a minimum resolution of 10 nanometers. Since nothing smaller can be accurately represented in the file, the CIF output of smaller geometries will generate errors.
GDS II (also called "Stream" format) is used as an interchange between design systems and fabrication facilities. For information on reading and writing GDS, see Section 3-9-2 and Section 3-9-3, respectively. In GDS files, there are no names for each layer, just a pair of numbers (the layer number and type). It is important that Electric know how these values correspond with layers so that it can properly read and write GDS files. You can set the correspondences by using the GDS Map File... command (in menu File / Import) to read a GDS map file. You can also use the "GDS" preferences dialog (in menu File / Preferences..., "I/O" section, "GDS" tab) to edit the GDS numbers and control other aspects of GDS input and output. | ![]() |
In the "GDS" preferences dialog, the list on the left shows all of the Electric layers in the current technology. By clicking on a layer name, its GDS numbers are shown in the top-right and can be edited. In addition to GDS numbers to use for layout, there are also two other types of GDS numbers: pin (for exports) and text (for export names).
These dialog elements apply to reading GDS:
These dialog elements apply to writing GDS:
EDIF (Electronic Design Interchange Format) is used to exchange design information between
different CAD systems.
Although EDIF is currently at version "4 0 0", Electric reads and writes version "2 0 0".
For more information on reading and writing EDIF, see
Section 3-9-2 and
Section 3-9-3, respectively.
EDIF options are controlled with the "EDIF" preferences
(in menu File / Preferences..., "I/O" section, "EDIF" tab).
This dialog controls whether EDIF output writes schematic or netlist views (the default is netlist). It also lets you set a scale factor for EDIF input. | ![]() |
![]() |
DEF (Design Exchange Format) is a recent interchange format for CAD systems.
It is often combined with LEF (Library Exchange Format) files.
For more information on reading and writing DEF or LEF, see
Section 3-9-2 and
Section 3-9-3, respectively.
DEF options are controlled with the "DEF" preferences
(in menu File / Preferences..., "I/O" section, "DEF" tab).
This dialog controls whether DEF reads physical and/or logical information. |
CDL (Circuit Description Language) is almost identical to Spice format,
and is used as a netlist interchange method.
CDL options are controlled with the "CDL" preferences
(in menu File / Preferences..., "I/O" section, "CDL" tab).
This dialog control the library name and path information that is written, and it lets you control the conversion of square-bracket characters. | ![]() |
This dialog controls the list of acceptable DXF layers. These layers can be typed into the edit field, separated by commas. If a layer name in the DXF file is not found in the list of acceptable layers, it will be ignored. If you check "Input reads all layers", then all layers are read into Electric, regardless of whether the layer names are known.
By default, Electric flattens DXF input, removing levels of hierarchy and creating a single cell with the DXF artwork. By unchecking the "Input flattens hierarchy", Electric will preserve the structure of the DXF file.
To control scaling, you can change the meaning of units in the DXF file. The default unit is "Millimeters", which means that a value of 5 in the DXF file becomes 5 millimeters in Electric.
This dialog controls whether transistors will appears in a standard 3-terminal configuration or in a 4-port configuration with a substrate connection.
![]() |
7-4-1: The MOS Technologies |
![]() |
There is one nMOS technology: "nmos" (the specifications used in the Mead and Conway textbook).
There are a few CMOS technologies available. The most basic is "cmos", which uses an idealized set of design-rules from a paper by Griswold. The most popular CMOS technology is "mocmos" (MOSIS design rules) which has two layers of polysilicon and up to 6 layers of metal with standard, submicron, or deep rules (this is described more fully in the next section). There is even "rcmos", which uses round geometry!
![]() | Each MOS technology has two transistors (enhancement and depletion in nMOS technologies, n and p in CMOS). These nodes can have serpentine paths by highlighting them and using "Outline Edit" mode (see Section 6-10-1). |
The contact cuts in the MOS technologies automatically increase the number of cut layers when the contact grows in size. For very large contacts, however, the display of these cuts can waste time. Therefore, when very large contacts are displayed at small scale, the interior cuts may not be drawn (as shown on the right). Be assured, however, that the cuts are actually there, and will appear in all appropriate output. | ![]() |
Although individual MOS nodes and arcs have the proper amount of implant around them, a collection of such objects may result in an irregular implant boundary. To clean this up, you can place pure-layer nodes of implant that neatly cover the implant area. Also, you can do this automatically with the Coverage Implants Generator command (in menu Tool / Generation).
This technology defaults to 4 metal layers (shown here), but can also be changed so that it uses anywhere from 2 to 6 layers of metal. It also has 1 polysilicon layer but can be changed to use 2. The technology can also be set to use either standard rules (SCMOS), submicron rules, or deep rules. You can choose whether to allow stacked vias and whether or not to use alternate contact rules. All of this is done with the "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab).
The MOSIS CMOS technology also has two scalable transistor nodes that can be parameterized to have different widths. The scalable transistors have contacts built into them. When created and scaled, their maximum width is shown. However, by adding a "width" attribute, they can shrink arbitrarily. Note that the ports remain in the same location regardless of the width, thus allowing them to scale without affecting constraints.
The scalable transistor on the left is 3 wide, and the other two are 10 wide. However, the scalable transistor on the right has had the "width" attribute set to 8 and so it has shrunk. Note that this attribute can be derived from cell parameters, causing different instances of the same cell to have different size transistors in it.
If you get Object Properties... on a scalable transistor, there are extra controls
that let you choose to have fewer contacts (1 or even none), and you can tighten the contact spacing.
Users of Electric version 6.02 or earlier will have a different MOSIS CMOS technology called "mocmossub". This technology attempted to match the submicron rule set, but did not do so as accurately as the current "mocmos" technology. If you have designs in that technology, they will be automatically converted to the new "mocmos" when read in. | ![]() |
![]() |
7-5-1: The Schematics Technology |
![]() |
There are two arcs in the Schematic technology: the wire (blue) and the bus (green). These arcs can be drawn at 45 degree angles. One typically names busses with array names (for example "insig[0:7]"), and then names wires with scalar names (for example "insig[1]"). See Section 6-9-3 for more on bus naming.
![]() |
To make a physical connection of a wire to a bus,
the bus pin can connect to either, so it acts as a tap.
In addition, the Wire Con node connects wires to busses,
or connects busses of different width, replicating the narrower side to make it as wide as the wider side.
Use the Rip Bus command (in menu Edit / Arc) to automatically add taps to a bus.
Digital schematics are built with the And, Or, Xor, Buffer, Multiplexor, and Flip-Flop nodes that appear in the component menu. By attaching arcs to these components and negating them (with the Toggle Port Negation command, in menu Edit / Technology Specific), these turn into NAND, NOR, Inverter, and many other specialized components. Note that the size of the negating bubble can be controlled by using the "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab), and setting the "Negating Bubble Size" value in the "Schematics" area. |
The And, Or, Xor, and Multiplexor nodes can accept any number of input connections on the left, so they require some care in wiring (see Section 1-11-5). The left side has one large input port that allows an arbitrary number of connections. Initially, wires may attach at only three input locations, spaced evenly along the left side. However, when all three locations are connected, the node automatically expands, adding additional space along the side for new arcs.
To properly wire inputs to an And, Or, Xor, or Multiplexor node, cursor placement is very important, for it determines which of the locations to use on the left side. If an arc gets connected in the wrong location, try connecting more arcs until one appears in the right place, and then delete the unwanted ones.
The Switch node can also take an arbitrary number of poles on its left side. Simply stretch it along the line of the poles and their number will grow.
The analog nodes (Resistor, Inductor, Capacitor, and Diode) have values on them which can be selected and edited. Double-clicking on them brings up a special dialog for editing their value.
There are four transistor entries in the menu. The two on the right are the n and p transistors. The two images on the left are actually popup menus that let you select any style of transistor. The difference between the two on the left is that the top one is for 3-port transistors, and the bottom one is for 4-port transistors.
The "Spice" entry presents a popup menu of Spice parts . More information about the use of these parts can be found in the Section 9-4-3.
The "Cell" entry presents a popup menu of all cell instances.
The "Global" entry provides two nodes: a "Global Signal" node defines a signal name that spans levels of hierarchy , and a "Global Partition" node allows globals to be treated locally. See Section 6-9-5 for more on global networks.
The Resistor can be treated as a connecting or nonconnecting node. By default, it does not connect the networks on its two ends, and this is the correct way to treat it when doing low-level simulation such as Spice. However, for higher-level simulations (such as Verilog) the resistor should be ignored and treated as if it connects its two networks. To make this happen, use the "Network" preferences (in menu File / Preferences..., "Tools" section, "Network" tab), and check "Ignore Resistors". Note that if resistors are being ignored, Spice deck generation will temporarily include them while the netlist is being created.
Some commands that analyze a schematic circuit need to know which layout technology will be used to fabricate the design. For example, when generating a Spice deck from a schematic, it is necessary to know the sizes and parasitics that are associated with the actual circuit. To set the layout technology to use for schematic circuits, use the "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab), and set the "Use scale values from this technology" popup.
You can add pages to the current multipage schematic with the Create New Page command (in menu Cell / Multi-Page Cells). You can delete the current page with Delete This Page. To advance to the next page, use Edit Next Page.
Older versions of Electric implemented multipage schematics with different view types ("p1", "p2", ...). If these views appear instead of proper pages, use the Convert old-style Multi-Page Schematics command.
As a graphical aid to schematic design, frames can be displayed in a cell by using the Cell Properties... command (in menu Cell). Multi-page schematics require a cell frame on every page, but their presence is optional in other cells.
![]() | The frame size can be "Half-A", "A", "B", "C", "D", and "E". The frame can be horizontal (landscape) or vertical (portrait). You can choose to display a title box in the lower-right corner. The designer name can also be set for each cell. |
Besides the designer name, cell frames have a company name and a project name. These values are not set for each cell, but instead are preferences that are set for each user. Individual libraries can override these defaults as well.
The "Frame" preferences (in menu File / Preferences..., "Display" section, "Frame" tab) lets you set all of these defaults. Note that the designer name is taken first from the cell, then from the library if the cell does not set a value, and finally from the general default if the library and cell do not set a value. | ![]() |
![]() |
7-6-1: The Artwork Technology |
![]() |
![]() |
This technology has nodes for many typical graphic objects such as rectangles,
triangles, circles, and arrowheads.
Polygonal and Spline nodes allow arbitrary shapes to be defined.
Of course, nodes from all other technologies can be used as special electronic symbols when artwork is generated.
Conversely, these artwork nodes can be used to embellish designs done in all other technologies.
Circles can be outlines (normal or thick) or filled. The default shape is round, but elongation of the node produces an ellipse. In addition, by using the Object Properties... command (in menu Edit / Properties), the outline circles can be reduced to a portion of the circle (from 1 to 360 degrees). |
Arrow heads can be drawn in two different styles: simple or filled. The simple arrow head is the default and consists of two lines. The filled arrow head looks better because it is made of polygons. Use the "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab), and set the "Arrows filled" checkbox in the "Artwork" area.
The "Export" entry creates an export for use in icons. After clicking on the entry, you have the choice of selecting "Wire", "Bus", or "Universal" exports (see Section 3-11-4 for more on icon generation).
There are four different polygon styles: opened, closed, filled, and spline. The opened polygon can be drawn with solid lines, dotted lines, dashed lines, or thicker lines. These nodes require that you use the "Outline Edit" mode (see Section 6-10-1).
The illustration below shows how outline information, applied to Artwork nodes, results in different shapes. In each of the shapes, the outline has the same 5 points, as illustrated in the upper-left. The nodes interpret this outline information to produce their shape. Note that the spline curve does not run through the outline points, only near them.
The final feature of the Artwork technology is its ability to set the appearance of any of its nodes or arcs. Use the Artwork Appearance... command (in menu Edit / Technology Specific) to set the color and pattern of any Artwork node or arc. Predefined patterns are available below the pattern-editing area. The transparent colors are taken from the current color map, which in turn is taken from the most recently selected technology (other than the Artwork technology). | ![]() |
The FPGA Architecture file contains all of the information needed to define a specific FPGA chip. It has three sections: the Primitive Definition section, the Block Definition section, and the Arcitecture section. The Primitive Definition section describes the basic blocks for a family of FPGA chips (these are primitives in the FPGA technology). The Block Definition section builds upon the primitives to create higher-level blocks. Finally, the Architecture section defines the top-level block that is the FPGA.
An FPGA Architecture file must have the Primitive Definition section, but it need not have the Block Definition or Architecture Sections. This is because the placement of the primitives can be saved in an Electric library, rather than the architecture file. Thus, after reading the Primitive Definition section (which creates the primitives), and reading the Block Definition and Architecture Sections (which places the primitives to create a chip library) the library can be saved to disk. Subsequent design activity can proceed by reading only the Primitive Definition section and then reading the library with the chip definition. This avoids large FPGA Architecture files (the Primitive Definition section will be smaller than the Block Definition and Architecture sections).
The Primitive Definition section defines the lowest-level blocks, which become primitive nodes in the FPGA technology. A primitive definition looks like this:
(primdef (attributes (name PRIMNAME) (size X Y) ) (ports (port (name PORTNAME) (position X Y) (direction input | output | bidir) ) ) (components (pip (name PIPNAME) (position X Y) (connectivity NET1 NET2) ) ) (nets (net (name INTNAME) (segment FROMPART TOPART) ) ) )
The attributes section defines general information about the block. The ports section defines external connections. The components section defines logic in the block (currently only PIPs). The nets section defines internal networks. There can be multiple segment entries in a net, each defining a straight wire that runs from the FROMPART to the TOPART. These parts can be either port PORTNAME or coord X Y, depending on whether the net ends at a port or at an arbitrary position inside of the primitive.
For example, this block has two vertical nets and two horizontal nets.
Four pips are placed at the intersections.
Six ports are defined (two on the left, two on the top, and two on the bottom).
The code is as follows:
(primdef | ![]() |
The Block Definition and Architecture sections define higher-level blocks composed of primitives. They looks like this:
(blockdef (attributes (name CHIPNAME) (size X Y) (wirecolor COLOR) (repeatercolor COLOR) ) (ports (port (name PORTNAME) (position X Y) (direction input | output | bidir) ) ) (components (instance (attributes ATTPAIRS) (type BLOCKTYPE) (name BLOCKNAME) (position X Y) (rotation ROT) ) (repeater (name BLOCKNAME) (porta X Y) (portb X Y) (direction vertical | horizontal) ) ) (nets (net (name INTNAME) (segment FROMPART TOPART) ) ) )The only difference between the Architecture section and the Block Definition section is that the Architecture section has the keyword architecture instead of blockdef. There can be only one architecture section, but there can be many blockdefs, defining a complete hierarchy.
The attributes section defines general information about the block.
The ports section defines external connections.
The components section defines logic in the block (currently instances of other blocks or repeaters). The rotation of an instance is the number of degrees counterclockwise, rotated about the center. The attributes section of the instance assigns name/value pairs (this can be used to program the FPGA).
The nets section defines internal networks. There can be multiple segment entries in a net, each defining a straight wire that runs from the FROMPART to the TOPART. These parts can be either component INSTNAME PORTNAME, port PORTNAME, or coord X Y, depending on whether the net ends at a component, port or at an arbitrary position inside of the block.
Here is an example of block definition code and its layout.
(blockdef | ![]() |
(ports
(port (name top0) (position 40 150) (direction bidir) )
(port (name top1) (position 60 150) (direction bidir) )
(port (name left0) (position 0 120) (direction input) )
(port (name left1) (position 0 100) (direction input) )
(port (name left2) (position 0 50) (direction input) )
(port (name left3) (position 0 30) (direction input) )
(port (name bot0) (position 40 0) (direction bidir) )
(port (name bot1) (position 60 0) (direction bidir) )
)
(nets
(net (name iv0)
(segment port top0 component block0 outtop1) )
(net (name iv1)
(segment port top1 component block0 outtop2) )
(net (name iv2)
(segment component block0 outbot1 component block1 outtop1))
(net (name iv3)
(segment component block0 outbot2 component block1 outtop2))
(net (name iv4)
(segment component block1 outbot1 port bot0) )
(net (name iv5)
(segment component block1 outbot2 port bot1) )
(net (name ih0)
(segment port left0 component r0 a) )
(net (name ih1)
(segment component r0 b component block0 inleft1) )
(net (name ih2)
(segment port left1 component r1 a) )
(net (name ih3)
(segment component r1 b component block0 inleft2) )
(net (name ih4)
(segment port left2 component r2 a) )
(net (name ih5)
(segment component r2 b component block1 inleft1) )
(net (name ih6)
(segment port left3 component r3 a) )
(net (name ih7)
(segment component r3 b component block1 inleft2) )
)
)
Once an FPGA is on the screen, two aspects of its display can be controlled: the wires and the text. Three commands control the display of wires: Show All Wires displays every wire, Show No Wires hides every wire, and Show Active Wires shows only the wires that have been connected to PIPs that have been programmed. Two commands control the display of text: Show Text displays text and Hide Text turns text display off.
Once an FPGA has been created, you can program the PIPs by selecting a component and using the Edit Pips... command. This will display a list of active PIPs on the component. For example, after clicking on one of the "SampleBlock" instances, you can type the string "pip1 pip4" to program two of the pips in that instance.
The Universal arc in the Generic technology is able to make a connection between any two components, even if they are in different technologies. This is useful when mixing technologies while still maintaining proper connectivity, for example when simulating. The Invisible arc attaches any two components, but makes no electrical connection. It is useful for constraining otherwise unrelated components. The Unrouted arc makes arbitrary electrical connections, like the universal arc, but routers know to replace them with real geometry. None of these arcs produce any actual geometry in IC descriptions, but they make important conceptual connections.
Any existing arc in a normal technology can be converted to one of these three special arcs by using the Change... command (in menu Edit).
There are also special nodes in the Generic technology. They are all available from the "Misc." entry of the component menu.
The Universal-Pin is a node that can connect to any arc. This is useful as an intermediate component when replacing (first you replace the unwanted node with a Universal-Pin to allow it to fit with the existing arcs; then you replace the arcs; finally you put the desired new node in place).
The Invisible-Pin is used for holding text,
and it does not appear in hardcopy output
(this is what is created when you use place Annotation Text).
This pin can also connect to any arc.
A special primitive, called Cell-Center, defines the origin of any cell. Once the node is placed, its location is at (0,0) for the cell. Since instances of the current cell use the origin as the anchor point for cursor-based references, the location of this node defines the anchor. For example, if you place this node in the upper-right corner of a cell, then creation commands place instances such that their upper-right corner is at the cursor. See Section 3-3 for more information on cell centers. | ![]() |
A special primitive, called Essential-Bounds, defines an alternate boundary of any cell. At least two of them must be placed in opposite corners, although 4 can be place to make it look better.
Note that the Cell-Center and Essential-Bounds nodes are made "hard-to-select" by default, which means that they can be selected only by using "Special Select" mode (see Section 2-1-5 for more).
A special primitive, called Simulation-Probe is recognized by simulators and visually modified to reflect whatever it is connected to. The simulators that reflect the state of the circuit by drawing lines along arcs also fill-in these probe nodes. It provides a visual display of simulation activity, and works especially well with the VCR controls in the waveform window. See Section 4-12-1 for more.
![]() |
8-1: Designing New Technologies |
![]() |
The editor works by converting a technology into a library of cells. You then edit the cells, using familiar Electric commands, and make changes to the technology. Finally, the technology editor translates the library back into a technology.
Libraries which describe a technology are called technology libraries.
They use elements from the Artwork technology to describe their information.
Special commands from the Edit / Technology Specific menu aid in the manipulation of these libraries.
There are four types of cells in a technology library which describe the layers, arcs, nodes, and support. They are separated into these groups in the cell explorer. The layer cells all begin with the name "layer-" and each one defines a layer in the technology. For example, the cell called "layer-Metal" defines the metal layer. The node and arc cells correspond to the primitives in the technology. Their names always begin with "node-" and "arc-". The support cell is always called "factors". Any other cell in the library is ignored. | ![]() |
![]() |
8-2: Converting between Technologies and Libraries |
![]() |
The best way to create a new technology is to change an existing one. Use the Convert Technology to Library for Editing... command (in menu Edit / Technology Specific) and select a similar technology. Unfortunately, the Schematic and Artwork technologies are too complex to edit and cannot be converted.
Conversion of a technology to a library creates a library with the same name as the technology. Note that technologies with options (such as MOSIS CMOS) will be converted with their current settings only, and the options will no longer be available.
Once a technology-library has been created, editing of its cells is done in a special technology-editing mode. The system knows to use technology-editing mode because the cells are marked as being "Part of a technology editor library" (see the Cell Properties... command of the Cells menu).
To convert a technology-library into a technology, use the Convert Library to Technology... command.
You are given the opportunity of naming the technology, and can also request that Java code be produced (this code can be compiled with Electric to install the technology permanently). If a technology already exists with the name you want, you can request that it be renamed, or you can choose a different name for the new technology (note that technologies can also be renamed with the Rename Current Technology... command). | ![]() |
If there is an error in the library, conversion is aborted and you are given a chance to fix the library. Generally, the offending part of the library is highlighted. If no errors have occurred in the translation, there will be a new technology in Electric and it will be the current one.
Before creating any circuitry with the new technology, it is advisable to create a new library (use the New Library... command of menu File) so that the test circuitry is not stored with the library that describes it.
After a few rounds of technology editing, there may be many libraries and technologies. You can delete the current library with the Close Library command of the File menu (to make another library current, use the Change Current Library... command of the File menu).
Once a library has been successfully built that describes a technology, it can be saved to disk with the Save Library command of the File menu. Then, in another session of Electric, it can be read from disk and converted to a technology.
![]() |
8-3: Hierarchies of Technology Libraries |
![]() |
To connect a sequence of libraries, a list is placed in the bottommost library pointing to the earlier, or "dependent" libraries. In the example below, the current library is "smallPads" and it is tailored with two other libraries: "pads" and "cmos" (the "base" library). Note that the list implicitly begins with the current library, and continues in reverse order. In this example, the first library examined is "padsSmall", followed by "pads" and finally the base library "cmos".
When a piece of technology information is found in more than one library, the latest one is used (i.e. the current library's version is used before a dependent library's version, and a dependent library's version is used before that of another dependent library higher up the list). Note that the version which is used is expected to be the most recently created version, and a warning message will be issued if this is not the case.
Control of the library list is done with the Edit Library Dependencies... command (in menu Edit / Technology Specific).
A dialog is presented with two lists of libraries. The list on the left shows the dependent libraries and the list on the right shows all current libraries. By selecting a library name from the list on the right and clicking on the "<< Add" button, it is added to the list on the left. To add a library not shown, type its name into the box on the right and click the "<< Add" button. | ![]() |
To remove a library from the list on the left, select it and click the "Remove" button.
![]() |
8-4: The Layers Cells |
![]() |
![]() | To create a new layer, use the context menu on the "TECHNOLOGY LAYERS" entry of the cell explorer and choose "Add New Layer". A layer can be deleted simply by deleting its cell. A layer can be renamed by renaming its cell, but remember to use the name "layer-" in front (i.e. the old name is "layer-metal" and the new name is "layer-metal-1"). Finally, you can rearrange the order in which the layers will be listed with the "Reorder Layers" command from the context menu. |
There are many pieces of information in a layer, most of which can be updated by double-clicking on them. There is a 16x16 stipple pattern, a large square of color above that, and a number of pieces of textual information along the right side. | ![]() |
The stipple pattern can be changed by double-clicking on any grid squares. You can also do operations on the entire stipple pattern ("Clear Pattern", "Invert Pattern", "Copy Pattern", and "Paste Pattern") by double-clicking on their name below the pattern area.
![]() | The color of the layer can be changed by double-clicking on the "Color" entry. The dialog lets you choose a color, opacity, and foreground factor for the layer. Opacity ranges from 1.0 (fully opaque) to 0 (transparent). The foreground flag is "on" to indicate that the non-opaque colors can be combined with others. |
Transparency lets a layer have a unique appearance where it overlaps other layers. The overlap is defined in the technology's color map. You can double-click on the "Transparency" entry to assign this factor to a layer. Non-transparent layers (with "Transparency: none") are opaque, so they obscure anything under them when drawn. In general, the most commonly used layers should be transparent. See Section 4-6-1 for more information on transparency.
The "Style" entry on the right can be "solid", "patterned", or "patterned/outline" to indicate how that layer will be appear. When using "solid" styles, the 16x16 stipple pattern is ignored (except for hardcopy). The "patterned/outline" option draws a solid line around all patterned polygons. Transparent layers should be solid because they distinguish themselves in the color map. Layers with opaque colors should probably be patterned so that their combination is visible.
Many of the entries on the right side of the layer cell provide correspondences between a layer and various interchange standards. The "CIF Layer" entry is the string to use for CIF I/O. The "GDS-II layer" entry can be as simple as a single layer number, but it can also be two numbers separated by a "/" (the layer number and its type). You can also add a comma and then another layer/type pair with the letter "t" (for text) or "p" (for pin) at the end.
Another set of options on the right side of the layer cell is for Spice parasitics. You may assign a resistance, capacitance, and edge capacitance to the layer for use in creating Spice simulation decks.
The "3D Height" and "3D Thickness" are used when viewing a chip in 3-dimensions. The height and thickness are arbitrary values which describe the location and thickness in the third axis (out of the screen). For example, to show how poly and diffusion interact, the poly layer can be at height 21 and the diffusion layer at height 20, both with 0 thickness. This will appear as two ribbons, one over the other. See Section 4-11 for more information on 3D display.
The last option on the right side of the layer cell specifies the minimum coverage percentage (see Section 9-2-3 for more).
The "Function" entry allows a general-purpose description to be attached to the layer. A function consists of a single base description plus optional additional modifiers. The additional modifiers are found in the last entries of the function list. | ![]() |
These additional modifiers can be added to the base function:
For example, you can double-click the function entry many times, selecting "Diffusion", "p-type", and "heavy" to indicate a Diffusion layer that is heavily-doped p-type. To clear the layer function, set it to "unknown."
A number of rules apply to the selection of layer functions. There must be a "pseudo" layer for every layer used to build arcs. This is because every arc needs a pin, and pins are constructed from "pseudo" layers. The "pseudo" layers are virtual geometry that do not appear in the fabrication output. It is important that every "pseudo" layer have an associated real layer, with similar descriptive fields. The technology editor will issue a warning if pins are not constructed from pseudo-layers.
Note that the layer functions must be treated carefully as they form the basis of subsequent arc and node definitions. One consideration to note is the use of "Wells" and their significance to the Spice extractor. If the technology requires a separate contact to the well, then it will typically contain a metal layer, and a piece of heavily doped material under the metal to make ohmic contact to the well; i.e. p++ in a P-well. This will have the same doping as the well, unlike a device diffusion, which is of opposite type to the well in which it is located.
Two rules apply here:
![]() |
8-5: The Arc Cells |
![]() |
Arcs are the wires in a technology, and they are constructed from pieces of geometry on the layers. To edit an existing arc, select it from the cell explorer or the Edit Cell... command (in menu Edit).
![]() | To create a new arc, use the context menu on the "TECHNOLOGY ARCS" entry of the cell explorer and choose "Add New Arc". |
An arc can be deleted simply by deleting its cell. An arc can be renamed by renaming its cell, but remember to use the name "arc-" in front (i.e. the old name is "arc-metal" and the new name is "arc-metal-1"). Finally, you can rearrange the order in which the arcs will be listed with the "Reorder Arcs" command from the context menu.
Arc cells show a sample arc on the bottom and a few pieces of textual information above it. The textual information can be updated by double-clicking on it.
The "Fixed-angle" entry lets you choose whether or not default arcs of this type are drawn at fixed angles
(the particular fixed angle is specified by the "Angle increment" field below).
In many layout technologies, the correct state is "yes".
The "Wipes pins" entry lets you choose whether or not these arcs completely erase connecting pins (the sensible state is "yes" because pins are drawn in the same layer and would not be visible anyway). | ![]() |
The "Extend arcs" entry lets you choose whether or not these arcs extend beyond their endpoints by half of their width (the typical state is "yes").
The "Angle increment" entry is the preferred angle granularity of this type of arc (the typical state is "90" which requests Manhattan arcs).
The "Antenna Ratio" entry is used in antenna rules calculations (see Section 9-3-2).
![]() | The "Function" entry describes the arc's function, which is a different set than the layer functions. As with layer functions, the arc functions should be carefully considered. |
A well arc that contains a well layer and does not contain device diffusion (i.e. opposite doping to the well) must not be defined as "diffusion"; it must be defined as "well-diffusion". This prevents the Spice extractor from incorrectly adding any p or n doped area found in the well arc to the source or drain area of a transistor on the same network. This does not mean that a device arc cannot contain a well layer. Device arcs will be declared as "p-diffusion" or "n-diffusion", and their well layer will be handled correctly; the arc connectivity is really defined by the device diffusion layer. For example, a p-device arc will have an N-well, or N substrate under it, and a p-type diffusion will end up as part of the drain or source of the P transistor to which it is connected.
In addition to the above information, the arc must also be described with pieces of geometry on the various layers. Thus, a prototypical arc must be drawn in this cell. The length of the arc is not important, but the smaller dimension is presumed to be the width and defines the default for this arc type.
Use the entries from the component menu of the side bar to create new layers. The typical layer in an IC technology is a Filled box (third from the top).
![]() |
After the geometry is created, it can be moved and resized with standard Electric commands.
Remember to keep all arc geometry separate from the information messages in the cell
so that the technology editor can distinguish them.
Once a piece of geometry is created,
its layer can be set by double-clicking on it.
A menu is then presented with possible layers (ignore the last entries, "SET-MINIMUM-SIZE",
and "CLEAR-MINIMUM-SIZE" which are used only for nodes).
Besides geometric layers, the graphical arc description must have a highlight layer to show where the arc will be outlined when used in a circuit. Although the highlighting is typically drawn around the outside of all geometry, implant layers may extend beyond the highlight (see the CMOS diffusion arcs for an example of this). Select the "HIGH" entry in the component menu to create this special type of layer. |
After geometry has been created, there may be some confusion as to what is there. To find out, use the Identify Primitive Layers command (in menu Edit / Technology Specific), which temporarily labels each piece of geometry in the arc cell.
![]() |
8-6: The Node Cells |
![]() |
Nodes are the components in a technology, and they are constructed from pieces of geometry on the layers. To edit an existing node, select it from the cell explorer or the Edit Cell... command (in menu Edit).
![]() | To create a new node, use the context menu on the "TECHNOLOGY NODES" entry of the cell explorer and choose "Add New Node". A node can be deleted simply by deleting its cell. A node can be renamed by renaming its cell, but remember to use the name "node-" in front (i.e. the old name is "node-metal" and the new name is "node-metal-1"). Finally, you can rearrange the order in which the nodes will be listed with the "Reorder Nodes" command from the context menu. |
The node cell contains four pictures of the node on the bottom and textual information above that.
You can update the textual information entries by double-clicking on them.
The "Serpentine transistor" entry indicates that this is a MOS transistor and it can take arbitrary outline information to describe its geometry. The "Square" entry forces the node to always have the same X and Y dimension when scaled. The "Invisible with 1 or 2 arcs" entry indicates that the node will not be drawn if it is connected to exactly one or two arcs. This is useful in schematic pins, which are visible only when unconnected or forming a junction of 3 or more wires. | ![]() |
The "Lockable" entry indicates that this node can be made unchangeable along with other lockable primitives, when the lock is turned on during editing (see Section 6-2 for more on locking these primitives). This is typically used in array technologies such as FPGA (see Section 7-6-2).
![]() | The "Function" entry describes the node's function, which is a different set than the arc and layer functions. A dialog offers a list of possible node functions. |
For nodes, it is common to sketch four different examples of the node in varying scales, so that X and Y scaling rules can be derived (square nodes need only two examples). If only one example is specified, default scaling rules will be presumed.
The smallest example, called the main example, is used as the default size and also contains all of the special port information. Needless to say, it is important to keep the geometry of each example well apart from the others so that the technology editor can distinguish them.
Each example must contain the same geometric layers (only stretched). As in the Arc cells, pieces of geometry can be created by selecting from the component menu of the side bar, creating the geometry, and then double-clicking to assign a layer. If any polygonal geometry is used (for example, the Filled polygon entry, sixth from the top), they require outline information to be assigned (see Section 6-10-1). If the Opened circle arc entry is selected (second from the bottom), you can specify the number of degrees of the circle with the Object Properties... command (in menu Edit / Properties).
Each example must also contain a highlight layer to indicate the correct highlighting on the display. Select the "HIGH" entry from the component menu to create this special type of layer.
Each example must also contain port information.
Select the "PORT" entry in the component menu to create this special type of layer.
You will have to provide a name for each port,
and the name must be the same on each example.
Ports on the main example must also have connectivity information (which arcs can connect to them) and range information (the permissible angle of connected arcs). Double-click on the port to set this. The range consists of two numbers: an angle (in degrees counterclockwise from 3 O'clock) and an angle range. For example, a port angle of 90 with a port angle range of 45 describes a port that points upward and can connect at angles up to 45 degrees off from this direction. The range will be graphically depicted. | ![]() |
The ports on the main example must also indicate any internal electrical connectivity by actually connecting them together. For example, the two polysilicon ports on a MOS transistor should be connected in the main example. Join the ports with a universal arc. Do not put this internal connection on any example other than the main one. To see the location of all ports on the main example, use the Identify Ports command (in menu Edit / Technology Specific).
As with arcs, use the Identify Primitive Layers command to label each piece of geometry in the main example.
There are some special cases available in node descriptions. A piece of geometry in the main example may be changed (by double-clicking on its function) to "SET-MINIMUM-SIZE". This indicates that the current size is the smallest possible, and it cannot scale any smaller (this is used by the "mocmos" technology for the metal layer in contacts). The restriction can be removed with the "CLEAR-MINIMUM-SIZE" description. This option cannot be used in serpentine transistors.
Another special case in node description is the ability to specify multiple cut layers. If the larger examples have more cut layers, rules are derived for cut spacing and indentation so that an arbitrary numbers of cuts can be inserted as the contact scales.
Although serpentine MOS transistors are a special case, they cannot be automatically identified, but must be explicitly indicated with a textual indicator. Besides this explicit indication, the transistor node must contain four ports: two on the gate layer (polysilicon) and two on the gated layer (active). A standard geometry must be used that shows polysilicon and diffusion crossing in a central transistor area. Any deviation from this format may cause the technology editor to be unable to derive serpentine rules for the node.
Besides the standard nodes for transistors, contacts, and other circuit elements, it is necessary to build pin and pure-layer nodes. There should be one pin for every arc, so that the arc can connect to others of its type. The pin should be constructed of pseudo-layers (i.e. it has no real geometry), should have the "pin" function, and should have one port in the center that connects to one arc. The technology editor will issue a warning if there is no pin node associated with an arc.
The pure-layer nodes should also be built, one for each layer. They should have only one piece of geometry and have the "pure-layer" function. The technology editor will issue a warning if there is no pure-layer node associated with a layer.
![]() |
8-7: Miscellaneous Information |
![]() |
Each cell in a technology library describes a different aspect of the technology. The support cell contains technology-wide information. To see this, edit the cell "factors" under the "TECHNOLOGY SUPPORT" section of the cell explorer.
The support cell contains many items, any of which can be changed by double-clicking on it.
Double-clicking on the "Transparent Colors" entry shows a dialog for selecting the transparent colors. You must define as many colors as you have used in the layers. | ![]() |
Unfortunately, it is not possible to edit design rules associated with the technology.
![]() |
8-8: How Technology Changes Affect Existing Libraries |
![]() |
Technology information appears in four different places: the layers, the arcs, the nodes, and miscellaneous information on the technology (the support cell and color tables). Information in these areas can be added, deleted, or modified. The rest of this section outlines all of these situations.
Adding information has no effect on the existing circuitry. All subsequent circuit design may make use of the new technology elements.
All references to a deleted layer, in any nodes or arcs of the technology, will become meaningless. This does not invalidate libraries that use the layers, but it does invalidate the node and arc descriptions in the technology. The geometry in these nodes and arcs will have to be moved to another layer.
This will cause error messages when libraries are read that make use of the deleted elements. When the library is read, you can substitute another node or arc to use in place of the now-unknown component.
This depends entirely on where that information is used. For example, an analysis tool may fail to find the information that it requires.
This is a totally transparent operation. Any change to the color, style, or stipple information (including changes to the color map) will appear in all libraries that use the technology. Changes to I/O equivalences or Spice parasitics will be available to all existing libraries. A change of the layer function may affect the technology editor's ability to decode the nodes and arcs that use this layer (for example, if you change the function of the "polysilicon" or "diffusion" layers that form a transistor, the editor will be unable to identify this transistor). Renaming a layer has no effect.
This is not as simple as layer modification because the arcs and nodes appear in the circuit libraries, whereas the layers do not. If you rename a node or arc, it will cause errors when libraries are read that make use of nodes with the old name. Therefore, you must create a new node or arc first, convert all existing ones to the new type, and then delete the old node or arc.
Many of the pieces of special information on the top of the node and arc cells apply to newly created circuitry only, and do NOT affect existing components already in libraries. The arc factors "Fixed-angle", "Wipes pins", "Extend arcs", and "Angle increment" have no effect on existing libraries. The node factor "Square node" also has no effect on existing circuitry and gets applied only in subsequent designs.
Other factors do affect existing circuitry. Changes to the "Function" field, in both arcs and nodes, pass to all existing components, thus affecting how analysis tools treat the old circuits. If the "Serpentine Transistor" field in nodes is turned off, any existing transistors that have serpentine descriptions will turn into large rectangular nodes with incorrect connections (i.e. get trashed). Unfortunately, it may become impossible to keep the "Serpentine Transistor" field on if the geometry does not conform to standards set by the technology editor for recognizing the parts. If a node is not serpentine, turning the factor on has no effect. Finally, the node factors "Invisible with 1 or 2 arcs" and "Lockable" correctly affect all existing circuitry.
A more common modification of arcs and nodes is to change their graphical descriptions. A simple rule applies to all such changes: if you change the size of the bounding box, it causes possibly unwanted proportion changes in all existing circuitry. This is because the bounding box information is all that is stored in the library, and layer sizes are defined in terms of that box.
For example, assume that there is an active arc defined with two layers: diffusion (2 wide) and well (8 wide). The arcs in the libraries are therefore recorded as being 8 wide (the largest size). The system knows that the diffusion is narrower than the overall arc by 3 on each side. | ![]() |
Now, if you change the well so that it is 10 wide, the system will define the diffusion to be narrower than the overall arc by 4 on each side, and for the existing 8-wide arcs, the diffusion will shrink to zero and disappear. These arcs must be resized individually, which can be tedious.
Here is an example of how node geometry changes can also make trouble. Assume that there is a transistor that has an active piece (2 wide) and a gate piece (2 wide). Each piece extends beyond the transistor area by 2, thus making the entire node 6x6 in size. The size of each cross piece will be defined to be 2 narrower than the bounding box on each side. If the pieces are changed so that they extend by only 1, then the definition of each strip will change to being 1 less than the box size on each side. All existing 6x6 transistors will suddenly have 4x4 gate areas where they used to be 2x2.
In both of these examples, it may be preferable to keep the old technology and give the new technology a different name. Then the old libraries can be read into the old technology, and the Make Alternate Layout View... command (in menu View) can be used to translate into the new technology. This command uses node and arc functionality to associate components, scaling them appropriately relative to their default sizes. The change is completed by deleting the old technology, renaming the new technology to the old name, and then saving the library.
This last situation is typically transparent: changed information appears in all existing libraries, and affects those subsystems that make use of the information. For example, a change to the Spice resistance will be seen when a Spice deck is next generated.
![]() |
8-9: Examples of Use |
![]() |
In this first example, the user simply wishes to change the Metal-2 layer from a solid fill to a stipple pattern.
This particular task is so basic that it can be done with the "Layers" preferences, but it illustrates the basic steps of making a change. First, edit the layer cell for "metal-2". The display will show the layer with all of its associated information.
Because every layer has a default stipple pattern used for printing, all that is necessary is to change the "Style" field from solid to patterned. To do this, double-click on the "Style" text and select "Patterned". The technology is now modified and can be converted back with the Convert Library to Technology... command.
The second example is more extensive: creation of a new primitive node. In this case, the new node is a contact between metal-2 and polysilicon.
To create the node, use the context menu on the "TECHNOLOGY NODES" tab of the explorer window, select "Create New Node", and name the node appropriately. | ![]() |
At this point, the display will show only the textual information about the node (because the graphical information is yet to be supplied). The textual information consists of five factors that now fill the screen.
![]() | You should begin by changing the "Function" factor to "contact" (double-click it and select the appropriate function). Then pan back so there is room to describe the node graphically. The other factors are properly set for a contact. |
To place a piece of geometry (for example, some polysilicon), click over the filled box entry in the component menu (third from the top) and then click in the edit window. This geometry now has shape, but no layer associated with it. To assign a layer, double-click on the geometry. Then choose "polysilicon-1". The black box will change appearance to that of a polysilicon layer. You can move and stretch this box appropriately. | ![]() |
In this example, assume that a contact between polysilicon and metal-2 has three layers: polysilicon-1, metal-2, and contact cut. Therefore, the above operation must be done two more times to place the metal-2 and contact cut layers.
Besides this pure geometry, there must be two other items in the node: a highlight layer and a port. The highlight layer is obtained by selecting the "HIGH" entry from the component menu. It is then placed and stretched so that it encloses the contact (highlight layers define the size of the node, and this means that they will typically surround the geometry).
![]() |
The other item that must be created is a port
(more than one can be created, but for contacts, one is sufficient).
Select the "PORT" entry from the menu on the left and place it in the display.
You will be prompted for a port name, after which you can further move or stretch the port.
Besides a location and a name, ports must specify which arcs may connect to them.
To do this, double-click on the port.
The resulting menu lists all of the arcs and indicates possible connectivity. Note that the last two entries define the permissible range of angles to which arcs may connect. For a contact such as this, arcs may connect at any angle, so the default values are correct. |
When all of the geometry, highlighting, and ports have been placed, you can double-check your work with the Identify Primitive Layers command (in menu Edit / Technology Specific), which will display this information (note that the port name "Center" has been moved away for clarity):
The final step in the definition of this node is to create three more copies that illustrate scaling in both axes. This is done simply by selecting all five objects and using the Duplicate command (in menu Edit). Once duplicated in a new location, each piece must be stretched appropriately. In this example, the contact cut is designed so that the number of cut elements grows with the node. Thus, when stretched horizontally or vertically, there are two cuts, and when stretched in both directions there are four cuts. The technology editor will determine precise multicut rules from the cut spacing and the amount of stretch, so that even more cuts will appear as the node grows larger. The finished node definition is shown below:
All that is necessary is to convert this library back to a technology, and the new technology will have this node.
Of course, the newly created technology is valid only during the current session. Therefore, to preserve this technology, save the library to disk. In subsequent sessions, you must read the technology library and convert it to a technology before using it. Alternatively, you can request the system to write Java code for the technology and compile it into Electric..
![]() |
9-1: Introduction to Tools |
![]() |
When a tool is running, it may take a long time. You can see it under the "JOBS" entry of the cell explorer (see Section 4-8).
After a tool has run, it may reports errors in the ERRORS section of the cell explorer. To browse these errors, use the Show Next Error and Show Previous Error commands (in menu Edit / Selection) or type the ">" an "<" keys.
A number of common tool controls are available from the "General" preferences (in menu File / Preferences..., "General" section, "General" tab), especially in the "I/O" and "Jobs" section.
Most netlisters insert date and version information in the comments at the head of the generated file. You can request that this information be omitted by unchecking "Include date and version in output files".
Most of the commands to generate an input deck for a simulator (a netlist) prompt the user for the desired file. If "Show file-selection dialog before writing netlists" is unchecked, however, the file is written (or overwritten) without prompt. This is useful in repetitive iterations of design/simulate, and saves the cumbersome file-selection dialog. However, it can be dangerous because it overwrites files without asking.
For more information about "Working directory", see Section 3-9-1.
In the "Jobs" section,
"Beep after long jobs" requests that any job which runs longer than a minute make a beep sound when done.
You can set the maximum number of errors that will be reported at once. By default, there is no limit to the number of errors. For more information about "Maximum undo history", see Section 6-7. For more information about the "Display" section, see Section 1-7 ("Show hierarchical cursor coordinates in status bar"), Section 4-8 ("Side Bar defaults to the right side"), Section 3-5 ("Always prompt for index when descending into array nodes"), and Section 4-4-2 ("Panning distance"). | ![]() |
For more information about the "Memory" section, see Section 1-3.
![]() |
9-2-1: Incremental DRC |
![]() |
To control the DRC, use the "DRC" preferences (in menu File / Preferences..., "Tools" section, "DRC" tab).
By default, the incremental design-rule checker is on.
To turn it off, uncheck the "On" checkbox in the "Incremental DRC" section.
MOS contact nodes automatically increase the number of cuts when they grow larger (see Section 7-4-1). Because of this, very large contact nodes can create excessive work for the design-rule checker as it examines each of the cuts. To save time, check the "Ignore center cuts in large contacts" check box, which will examine only the cut layers around the edges of contact nodes. | ![]() |
DRC rules for new technologies might require special rules, which can be time consuming. To ignore these errors, check "Ignore area checking" (for minimum area rules) and "Ignore extension rules" (for special overlap rules).
After analysis of the circuit, you can review the errors by typing ">" and "<" to step to the next and previous error that was found. You can also see a list of errors in the cell explorer (see Section 4-8).
After analysis of the circuit, you can review the errors by typing ">" and "<" to step to the next and previous error that was found. You can also see a list of errors in the cell explorer (see Section 4-8).
After a cell has passed Hierarchical DRC with no errors, it is tagged with the current date. In subsequent runs of the Hierarchical DRC, if the cell has not been modified since that date, it is not rechecked. (However, if you change the DRC rules or the technology options, all date information is cleared.) If you wish to force all cells to be rechecked, use the "Clear valid DRC dates" button in the "DRC" preferences (in menu File / Preferences..., "Tools" section, "DRC" tab). To see which cells have passed Hierarchical DRC, use the General Cell Lists... command (in menu Cell / Cell Info) A "D" is shown in on the right for cells that are DRC current (see Section 3-7-1).
There are three levels of checking that can be requested in the "DRC" preferences, each consuming more time and finding more errors.
To check for proper minimum layer coverage, use the Check Area Coverage command
(in menu Tool / DRC).
To control the coverage rules, use the "Coverage" preferences
(in menu File / Preferences..., "Tools" section, "Coverage" tab).
Each layer in the technology has a minimum percentage of coverage that is needed.
The coverage check proceeds in a "tiled" manner, checking rectangular areas of the cell. For example, to check each 100x100 unit area of the cell, set "Width" and "Height" to 100, and set "DeltaX" and "DeltaY" to 100. | ![]() |
The List Layer Coverage on Cell command is another way to compute the percentage of the cell that is covered by each layer. This command covers the entire cell without breaking it into tiled rectangles.
Electric is able to read the output of Cadence's Assura design-rule checker. These error files (with the extension ".err") can be read with the Import Assura DRC Errors... command (in menu Tool / DRC). After reading the error file, you can review the errors by typing ">" and "<" to step to the next and previous error that was found. You can also see a list of errors in the cell explorer (see Section 4-8).
Four types of errors are detected by the incremental and hierarchical design-rule checkers. Spacing errors are caused by geometry that is too close, but not connected. Notch errors are caused by geometry that is too close, but connected. Minimum size errors are caused by geometry that is too small. Resolution errors are caused by geometries that are smaller than a requested resolution amount.
In addition to examining geometry, the design-rule checkers use connectivity information to help find violations. This use of network information helps the designer to debug circuit connectivity. For example, if two overlapping nodes are not joined by an arc, they may be considered to be in violation, even if their geometry looks right. This is because the checkers know what is connected and have a separate set of rules for such situations.
To help guide the design-rule checker, a "cloaking" layer can be placed over areas that are not to be examined. This cloaking layer is created by clicking the "Misc." entry of the component menu and selecting "DRC Exclusion". Any errors that fall inside of this node's area are ignored.
To edit the design rules, use the "Design Rules" preferences (in menu File / Preferences..., "Technology" section, ""Design Rules" tab). The dialog allows you to examine and modify the spacing limits for the current technology. Each rule has a numeric value (size or distance) as well as a textual description of the rule. The dialog is divided into two parts: "Node Rules" and "Layer Rules".
In the "Node Rules" section, you may set the minimum size of each node in the current technology.
In the "Layer Rules" section, you may set the minimum size, area, and enclosure area of each layer. You may also set the inter-layer spacing (between the "From Layer" and the "To Layer"). Use the "Show only 'to' entries with rules" to restrict the displayed rules to those with valid values.
The layer-to-layer spacing rules appear in 3 forms: normal, wide, and multicut. Normal and multicut rules come in two flavors: connected and unconnected. The connected rules apply to pieces of geometry that are electrically connected; the unconnected rules apply to unconnected geometry. The normal rules also have a special Edge rule applies only to unconnected layers and ignores overlap when considering spacing distance.
The wide rules apply to large geometry. Although some technologies may have many different rules for different definitions of "large", the MOSIS CMOS technology has only one such rule, if the width is greater than a specified value.
The bottom of the dialog has some special features of design rules:
Note that the MOSIS CMOS design rule 6.7b is not checked by Electric because it is difficult to detect properly. This error is never fatal, and the worst case of missing this error is that active and poly are closer by 1/2 lambda, which merely results in an increase in capacitive coupling between them. If this fringing capacitance is important, you've probably got so much polysilicon in your circuit that it has bigger problems.
![]() |
9-3-1: Well and Substrate Checking |
![]() |
After analysis is done, you can review the errors by typing ">" to see the next error and "<" to see the previous error. You can also see the list of errors in the cell explorer (see Section 4-8).
You can control the Well Checker with the "Well Check" preferences (in menu File / Preferences..., "Tools" section, "Well Check" tab).
The Well Checker makes sure that there are well contacts in every area of well. The dialog allows you to relax that restriction and demand only 1 well contact in each cell, or not to check for contacts at all.
The Well Checker also checks that there is a connection to power and ground in the appropriate places. You can disable these checks in the "Well Check" dialog.
An additional well check is to find the farthest distance from a substrate contact to the edge of that area. This check takes more time to do, and so it can be disabled.
The Well Checker can check spacing rules between well areas. Although this is generally the domain of the Design Rule Checker (DRC), it could be done here by checking "Check DRC Spacing Rules for Wells". Since the well checker has not been designed for DRC purposes, the algorithm is not efficient and therefore the option is off by default.
Finally, the Well Checker reports the maximum distance from a well contact to any point on the well. This is useful when making sure that there are sufficient contacts for each area.
To check for antenna rule violations, use the Antenna Check command (in menu Tool / ERC ). After analysis is done, you can review the errors by typing ">" to see the next error and "<" to see the previous error. You can also see the list of errors in the cell explorer (see Section 4-8).
You can control the Antenna Checker with the "Antenna Rules" preferences (in menu File / Preferences..., "Tools" section, "Antenna Rules" tab). The dialog lets you modify the required ratio of a layer (poly or metal) to the transistor area. | ![]() |
![]() |
9-4-1: Introduction to Simulation |
![]() |
Be aware that the Electric distribution does not come packaged with these external simulators. You must get your own copy of Spice, Verilog, or any other simulator mentioned here.
Electric can write netlists for these simulators:
Simulator | Level | Netlist Command (in Tool / Simulation) |
ArchSim | functional | Write ArchSim Deck... (Others) |
CDL | circuit | Write CDL Deck... (Spice) |
COSMOS | switch | Write COSMOS Deck... (Others) |
ESIM/RNL | switch | Write ESIM/RNL Deck... (Others) |
FastHenry | inductance | Write FastHenry Deck... (Others) |
IRSIM | switch | Write IRSIM Deck... (Others) |
Maxwell | circuit | Write Maxwell Deck... (Others) |
MOSSIM | switch | Write MOSSIM Deck... (Others) |
PAL | gate | Write PAL Deck... (Others) |
RSIM | switch | Write RSIM Deck... (Others) |
SILOS | functional | Write SILOS Deck... (Others) |
Spice | circuit | Write Spice Deck... (Spice) |
Tegas | functional | Write Tegas Deck... (Others) |
Verilog | functional | Write Verilog Deck... (Verilog) |
The ArchSim simulator is a special-purpose experimental simulator. Output from it can be displayed in a waveform window by using Display ArchSim Journal... (in menu Tool / Simulation (Others)).
For more information on Spice, Verilog, and FastHenry, see the following pages.
After running a Verilog simulation, you can read the ".dump" file into Electric and display it in a waveform window. This is done with the Plot Verilog VCD Dump... command (in menu Tool / Simulation (Verilog)). You can also use the Plot Verilog for This Cell command if the cell name and file name are the same. The Verilog simulation information is then shown in a digital waveform window (see Section 4-12-1 for more).
Before generating Verilog decks, it is possible to annotate circuits with additional Verilog declarations and code that will be included in the deck. To add Verilog code, select "Verilog Code" under the "Misc." entry in the component menu of the side bar. To add a Verilog declaration, select "Verilog Declaration" under the "Misc." entry in the component menu. These pieces of text can be manipulated like any other text object (see Section 6-8-1 on text).
Additional control of Verilog deck generation is accomplished with the "Verilog" preferences (in menu File / Preferences..., "Tools" section, "Verilog" tab). A checkbox lets you choose whether or not to use the Verilog "assign" construct. You can control the type of Verilog declaration that will be used for wires ("wire" by default, "trireg" if checked). Note that this can be overridden with the Set Verilog Wire command (in menu Tool / Simulation (Verilog)).
Another properety that can be assigned to transistors is their strength. The Weak command (in menu Tool / Simulation (Verilog) / Transistor Strength) sets the transistor to be weak. The Normal command restores the transistor to be normal strength.
The Verilog preferences dialog also lets you attach disk files with Verilog code to any cell in the library. Once attached, the generated Verilog will use the contents of that file instead of examining the cell contents. This allows you to create your own definitions in situations where the derived Verilog would be too complex or otherwise incorrect. For an example of Verilog layout and code, look at the cell "tool-SimulateVERILOG" in the Samples library (get this library with the Load Library command, in menu Help / Samples).
Once Spice has been run, you can see a plot of the simulation by reading the Spice output file back into Electric. Since there are may formats of Spice output, you must first set the "Spice Engine" and the "Output format" fields of the "Spice" Preferences (in menu File / Preferences..., "Tools" section, "Spice" tab). The "Output format" field is "Standard" for the default output of the Spice engine; "Raw" for rawfile dumps; and "Raw/Smart" for the rawfile dumps from SmartSpice.
When Electric knows what type of Spice output file to expect, use the Plot Spice Listing... command (in menu Tool / Simulation (Spice)) to read the file. If the file has the same name as the current cell, you can more simply use Plot Spice for This Cell, which does not need to prompt for a file name. The Spice simulation information is shown in an analog waveform window (see Section 4-12-2 for more).
There are many powerful facilities for running Spice with Electric. The example shown here illustrates some of these facilities. This example is available in the Samples library as cell "tool-SimulateSpice" (you can read the library with the Load Library command, in menu Help / Samples).
All input values to Spice are controlled with special nodes, found in the "Spice" component menu entry. Note that the first time any Spice node is placed, the library of Spice parts is loaded into Electric, so there may be a delay. | ![]() |
The Spice primitives described here are for Electric's default set. However, additional sets can (and have) been written. To choose another set, use the "Spice" preferences (in menu File / Preferences..., "Tools" section, "Spice" tab). Under the setting "Spice primitive set", choose another set. A second set, called "SpicePartsS3", is tailored towards special Spice3 primitives.
![]() |
In this example, there is a 5-volt supply on the left.
It was created by using the "DC Voltage" entry under "Spice" entry of the component menu.
Once placed, the text that reads "Voltage=0V" can be selected and modified
(either with Object Properties... or by double-clicking on it).
The Pulse input signal on the right is created with the "Pulse" entry under "Spice" (it has 7 parameters).
There are both voltage and current sources, in AC and DC form. The pulse input sources are available as voltage and current. A set of "two-gate" devices are also available: "CCCS", "CCVS", "VCCS", "VCVS", and "Transmission". It is possible to specify Transient, DC, or AC analysis by using the "Transient Analysis", "DC Analysis", and "AC Analysis" subcommands. Only one such element may exist in a circuit. |
For advanced users, there are two special Spice nodes: "Node Set" and "Extension". The Node Set may be parameterized with an arbitrary piece of Spice code. Truly advanced users may create their own Spice nodes by modifying the cells in the Spice library.
This example also shows the ability to add arbitrary text to the Spice deck, as shown in the lower-right. To create this text, use the "Add Spice Card" under the "Misc." button in the component menu. The command creates a piece of text that can be modified arbitrarily. Whatever the text says will be added to the Spice deck.
Another option that can be used when modeling transistors and other component is to set a specific Spice model to use for that component. To set a node's model, select it and use the Set Spice Model... command (in menu Tool / Simulation (Spice)).
The Add Multiplier subcommand places a multiplier on the currently selected node. Multipliers (also called "M" factors) scale the size of transistors inside of them.
Some nongraphical information can also be given to the Spice simulator with the "Spice" preferences (in menu File / Preferences..., "Tools" section, "Spice" tab).
The top part of this dialog allows you to control many of the Spice deck parameters such as:
Running Spice: Electric can create an external process as specified by the user to run Spice on the generated netlist. If the pull-down box is set to "Don't Run", nothing is done. If the pull-down box is set to "Run, Ignore Output", the external process is run, and the user is notified when it is finished. If set to "Run, Report Output", a dialog box is opened to show the user the output produced by the process. Please note that this is a *process*, and not a command line command.
There are several options for the process:
The lower section controls header and trailer cards (placed at the start and end of the Spice deck). This dialog allows you to specify a disk file with cards to be used instead of the built-in set. You can specify a particular file or request that the system search for files with the cell's name and a given extension.
Note that the header and trailer information is specific to a particular technology. If you set this information for one technology, but then use another technology when generating the Spice deck, the information that you set will not be used. Note also that schematics, although a technology in Electric, are not considered to be Spice technology. You can set the proper layout technology that you want to use when dealing with schematics by using the "Use Scale values from this Technology" popup. This popup can be found in the "Technology" preferences (in menu File / Preferences..., "Technology" section, "Technology" tab).
The bottom section of the dialog allows you to specify a disk file of Spice cards that will be used to describe any cell. Instead of the cell subcircuit, the specified disk file is "included" in the deck.
Users can define their own Spice or Verilog elements by creating new icons in this or a new library. The icon should have graphics, exports, optional parameters, and a template. Parameters are created with the Attribute Properties... command (in menu Edit / Attributes ). See Section 6-8-6 for more on parameters. The Spice template is created with the Set Generic Spice Template command (in menu Tool / Simulation (Spice)). If the template is specific to a particular version of Spice, use the appropriate template command (Set Spice 2 Template, Set Spice 3 Template, Set HSpice Template, Set PSpice Template, Set GnuCap Template, or Set SmartSpice Template).
You can also create Verilog elements by using the Set Verilog Template command (in menu Tool / Simulation (Verilog)). Note that a single cell can contain both Verilog and multiple Spice templates.
To explain the format of a template, a DC Voltage Source primitive is used as an example.
Graphics is placed to describe the look of the symbol (a "battery" look).
Exports are created at the top and bottom of the battery with the names "plus" and "minus".
A single parameter is defined called "Voltage" with a default value of "0V".
Finally, a Spice template is created that has the string
V$(node_name) $(plus) $(minus) DC $(Voltage) | ![]() |
This string contains substitution expressions of the form $(SOMETHING)
where SOMETHING
can be an export name, a variable, or "node_name".
So, in this example, $(node_name)
will be replaced with the name of the voltage node;
$(plus)
will be replaced with the net name attached to the positive terminal;
$(minus)
will be replaced with the net name attached to the negative terminal;
and $(Voltage)
will be replaced with the voltage value specified by the user.
The set of Spice primitives in Electric is useful, but far from complete. A second set, called "SpicePartsS3", is tailored towards special Spice3 primitives. There are no Verilog primitives in the current release of Electric. Users who define new primitives are encouraged to share these with the entire community by contacting Static Free Software.
This command presents a dialog with FastHenry factors for the selected arc. The most important factor is at the top: "Include this arc in FastHenry analysis". By checking this, the arc is described in the FastHenry deck. Once this is checked, other fields in the dialog become active. You can set the thickness of this arc (the default value shown will be used if no override is specified). You can set the number of subdivisions that will be used in height and width (again, defaults are shown). You can even set the height of the two ends of the arc. | ![]() |
After all arcs have been marked, you can generate a FastHenry deck with the Write FastHenry Deck... command (in menu Tools / Simulation (Others)). Before doing that, however, you can set other options for FastHenry deck generation. To do this, use the "FastHenry" preferences (in menu File / Preferences..., "Tools" section, "FastHenry" tab).
This dialog allows you to set the type of frequency analysis (single frequency or a sequence specified by a start, end, and number of runs per decade). You can choose to use single or multiple-pole analysis (and if multiple, you can specify the number of poles). The FastHenry Options dialog also allows you to set defaults for the individual arcs that will be included in the deck. You can specify the default thickness, and the default number of subdivisions (in height and width).
![]() |
9-5-1: IRSIM |
![]() |
To simulate the current cell with IRSIM, use the IRSIM: Simulate Current Cell command (in menu Tool / Simulation (Built-in)). After issuing this command, a waveform window will appear to control the simulation (see Section 4-12-1 for more). To generate an input deck for IRSIM without running the simulator, use the IRSIM: Write Deck... command. To simulate an IRSIM deck (that is, simulate the file, not the circuit), use the IRSIM: Simulate Deck... command. Note: if these commands do not appear in the menu, then IRSIM has not been installed.
Since the IRSIM engine is running inside of Electric, you can place stimuli on the circuit and see the results immediately (also described in Section 4-12-1). Note that the command to save stimuli (Save Stimuli to Disk... of menu Tool / Simulation (Built-in)) writes an IRSIM "command file" which can be edited by hand.
The "Simulators" preferences (in menu File / Preferences..., "Tools" section, "Simulators" tab),
offers some controls for IRSIM.
The general controls at the top are discussed in Section 4-12-1.
IRSIM uses a parameter file to describe timing and parasitic information. Two of these files come packaged with Electric ("scmos0.3.prm" and "scmos1.0.prm"), but you can create your own and tell IRSIM to use it. In addition to the parameter file, you can select the simulation model that IRSIM uses. The default is a RC model, but a Linear model is also available. Advanced users who edit their own command files may enter specialized IRSIM debugging commands. These commands depend on a set of flags to determine the type of debugging to do. Checkboxes in the "IRSIM Debugging" section control these debugging flags. | ![]() |
The bottom section has two miscellaneous IRSIM controls.
For an example of ALS simulation, load the "samples" library and simulate the cell "tool-SimulateALS{sch}". You can load the samples library with the Load Library command (in menu Help / Samples).
To begin simulation of the circuit in the current window, use the ALS: Simulate This Cell command (from menu Tools / Simulation (Built-in)). After issuing this command, a waveform window will appear to control the simulation (see Section 4-12-1 for more). Since the ALS engine is running inside of Electric, you can place stimuli on the circuit and see the results immediately.
ALS is able to handle transistors with varying strength. To set a transistor to be weak, use the Weak command (in menu Tool / Simulation (Verilog) / Transistor Strength). To restore the strength to normal, use the Normal command. Note that this must be done before simulation begins.
The "Simulators" preferences (in menu File / Preferences..., "Tools" section, "Simulators" tab) has some controls that affect ALS simulation. The "Multistate display" check tells the simulator to show waveform signals with different colors to indicate different strengths. Without this, a single color is used everywhere. The other general controls at the top are discussed in Section 4-12-1.
The user should be aware that the ALS simulator translates the circuit into VHDL, then compiles the VHDL into a netlist for simulation. This means that when a layout or schematic is simulated, two new views of that cell are created: {VHDL} and {net.als}. Use the Edit VHDL View (in menu View) to see the VHDL code. | ![]() |
When simulation is requested, the cell in the current window is simulated. Date checking is performed to determine whether VHDL translation or netlist compilation is necessary. If you are currently editing a VHDL cell, it will not be regenerated from layout, even if the layout is more recent. Similarly, if you are currently editing a netlist cell, it will not be regenerated from VHDL, even if that VHDL is more recent. Thus, simulation of the currently edited cell is guaranteed.
Note that the presence of VHDL in the path to simulation means that it can simulate VHDL that is entered manually. You can type this VHDL directly into the cell (see Section 4-10 for more on text editing). Also, you can explicitly request that VHDL be produced from schematics or layout with the Make VHDL View command (in menu View).
This complete VHDL capability, combined with the Silicon Compiler which places and routes from VHDL descriptions, gives Electric a powerful facility for creating, testing, and constructing complex circuits from high-level specifications. See Section 9-12 for more on the Silicon Compiler.
When the VHDL for a circuit is compiled into a netlist, both connectivity and behavior are included. This is because the netlist format is hierarchical, and at the bottom of the hierarchy are behavioral primitives. Electric knows the behavioral primitives for MOS transistors, AND, OR, NAND, NOR, Inverter, and XOR gates. Other primitives can be defined by the user, and all of the existing primitives can be redefined.
To create (or redefine) a primitive's behavior, simply create the {net.als} view of the cell with that primitive's name. Use the New Cell... command (in menu Cell) and select the "netlist.als" view. For example, to define the behavior of an ALU cell, edit "alu{net.als}", and to redefine the behavior of a two-input And gate, edit "and2{net.als}". The compiler copies these textual cells into the netlist description whenever that node is referenced in the VHDL.
The netlist format provides three different types of entities: model, gate, and function. The model entity describes interconnectivity between other entities. It describes the hierarchy and the topology. The gate and function entities are at the primitive level. The gate uses a truth-table and the function makes reference to Java-coded behavior (which must be compiled into Electric, see the module "com.sun.electric.tool.simulation.als.UserCom.java"). Both primitive entities also allow the specification of operational parameters such as switching speed, capacitive loading and propagation delay. (The simulator determines the capacitive load, and thus the event switching delay, of each node of the system by considering the capacitive load of each primitive connected to a node as well as taking into account feedback paths to the node.)
A sample netlist describing an RS latch model is shown below. Note that the "#" character starts a comment.
![]() |
# model declaration for the figure model main(set, reset, q, q_bar) inst1: nor2(reset, q_bar, q) inst2: nor2(q, set, q_bar) # gate description of nor2 gate nor2(in1, in2, out) t: delta=4.5e-9 + linear=5.0e-10 i: in1=L in2=L o: out=H@2 i: in1=H o: out=L@2 i: in2=H o: out=L@2 i: o: out=X@2 |
When combined, these entities represent a complete description of the circuit. Note that when a gate, function, or other model is referenced within a model description, there is a one-to-one correspondence between the signal names listed at the calling site and the signal names contained in the header of the called entity.
The ALS simulator simulates a set of simulation nodes. A simulation node is a connection point which may have one or more signals associated with it.
A simulation node can have 3 values (L, H, or X) and can have 4 strengths (off, node, gate, and VDD, in order of increasing strength). It is thus a 12-state simulator. In deciding the state of a simulation node at a particular time of the simulation, the simulator considers the states and strengths of all inputs driving the node.
![]() | Driving inputs may be from other simulation nodes, in which case the driving strength is "gate" (i.e. H(gate) indicates a logic HIGH state with gate driving strength), from a power or ground supply ("VDD" strength) or from the user (any strength). If no user vector has been input at the current simulation time, then the input defaults to the "off" strength. |
In the above example, the combination of a high and a low driving input at the same strength from the signals "out" and "in2" result in the simulation algorithm assigning the X (undefined) state to the output signal represented by "q". This example also shows the behavior of part of the simulation engine's arbitration algorithm, which dictates that an undefined state exists if a simulator node is being driven by signals with the same strength but different states, providing that the strength of the driving signals in conflict is the highest state driving the node.
Another important concept for the user to remember is that the simulator is an event-driven simulator. When a simulation node changes state, the simulation engine looks through the netlist for other nodes that could potentially change state. Obviously, only simulation nodes joined by model, gate or function entities can potentially change state. If a state change, or event, is required (based on the definition of the inter-nodal behavior as given by the model, gate or function definition), the event is added to the list of events scheduled to occur later in the simulation. When the event time is reached and the event is fired, the simulator must again search the database for other simulation nodes which may potentially change state. This process continues until it has propagated across all possible nodes and events.
The gate entity is headed by the gate declaration statement and is followed by a body of information. The gate declaration contains a name and a list of exported simulation nodes (which are referenced in a higher level model description). The format of this statement is shown below:
Format: | gate name(signal1, signal2, signal3, ... signalN) |
Example: | gate nor2(in1, in2, out) |
gate and3(a, b, c, output) |
There is no limit on the number of signal names that can be placed in the list. If there is not enough room on a single line to accommodate all the names, simply continue the list on the next line.
The i: and o: statements are used to construct a logical truth table for a gate primitive. The signal names and logical assertions which follow the i: statement represent one of many possible input conditions. If the logic states of all the input signals match the conditions specified in the i: statement, the simulator will schedule the outputs for updating (as specified in the corresponding o: statement). The logical truth table for a two input AND gate is shown below:
gate and2(in1, in2, output) i: in1=H in2=H o: output=H i: in1=L o: output=L i: in2=L o: output=L i: o: output=XThe last line of the truth table represents a default condition in the event that none of the previous conditions are valid (e.g. in1=H and in2=X). It should be noted that the simulator examines the input conditions in the order that they appear in the truth table. If a valid input condition is found, the simulator schedules the corresponding output assignments and terminates the truth table search immediately.
Besides testing the logical values of a signal, the i: statement can also compare them numerically. The format of a signal references, which follow the i: statement, is show below:
Format: | signal <operator> state_value |
or: | signal <operator> other_signal |
Operators: | = Test if equal |
! Test if not equal | |
< Test if less than | |
> Test if greater than | |
Example: | node1 = H |
input1 ! input2 | |
node3 < 16 |
There is no limit on the number of signal tests that can follow an i: statement. If there is not enough room on a single line to accommodate all the test conditions, the user can continue the list on the next line of the netlist.
The signal references which follow the o: statement are used as registers for mathematical operations. It is possible to set a signal to a logic state and it is possible to perform mathematical operations on its contents. The format for signal references which follow the o: statement is shown below:
Format: | signal [ <operator> operand [ @ <strength> ] ] |
Operators: | = equate signal to value of operand |
+ increment signal by value of operand | |
- decrement signal by value of operand | |
* multiply signal by value of operand | |
/ divide signal by value of operand | |
% modulo signal by value of operand | |
Strengths: | 0 off |
1 node | |
2 gate | |
3 VDD | |
Example: | qbar = H@3 |
out1 + 3 | |
out + out1@4 | |
node1 % modulus_node |
It should be noted that the logic state of the operand can be directly specified (such as H, 3) or it can be indirectly addressed through a signal name (such as out1, modulus_node). In the indirect addressing case, the value of the signal specified as the operand is used in the mathematical calculations. The strength declaration is optional and if it is omitted, a default strength of 2 (gate) is assigned to the output signal.
The propagation delay time (switching speed) of a gate can be set with the t: statement. The format of this statement is shown below:
Format: | t: <mode> = value { + <mode> = value ... } |
Mode: | delta: fixed time delay in seconds |
linear: random time delay with uniform distribution | |
random: probability function with values between 0 and 1.0 | |
Example: | t: delta=5.0e-9 |
t: delta=1.0e-9 + random=0.2 |
It is possible to combine multiple timing distributions by using the + operator between timing mode declarations. The timing values quoted in the statement should represent the situation where the gate is driving a single unit load (e.g. a minimum size inverter input).
The t: statement sets the timing parameters for each row in the truth table (i: and o: statement pair) that follows in the gate description. It is possible to set different rise and fall times for a gate by using more than one t: statement in the gate description. Assuming that a 2 input NAND gate had timing characteristics of t(lh) = 1.0 nanoseconds and t(hl) = 3.0 nanoseconds, the gate description for the device would be as follows:
gate nand2(in1, in2, output) t: delta=3.0e-9 i: in1=H in2=H o: output=L t: delta=1.0e-9 i: in1=L o: output=H i: in2=L o: output=HThis example shows that when both inputs are high, the output will go low after a delay of 3.0 nanoseconds and that if either input is low, the output will go high after a delay of 1.0 nanosecond.
The Delta timing distribution is used to specify a fixed, non-random delay. The format of a delta timing declaration is shown below:
Format: | delta = value |
Example: | delta = 1.0 |
delta = 2.5e-9 |
The value associated with the delta declaration represents the fixed time delay in seconds (1.0 = 1 second, 2.5e-9 = 2.5 nanoseconds, etc.)
The Linear timing distribution is used to specify a random delay period that has a uniform probability distribution. The format of a linear timing declaration is shown below:
Format: | linear = value |
Example: | linear = 1.0 |
linear = 2.0e-9 |
The value associated with the linear declaration represents the average delay time (in seconds) for the uniform distribution. This means that there is an equally likely chance that the delay time will lie anywhere between the bounds of 0 and 2 times the value specified.
The random probability function enables the user to model things which occur on a percentage basis (e.g. bit error rate, packet routing). The format for random probability declaration is shown below:
Format: | random = value |
Example: | random = 0.75 |
random = 0.25 |
The value associated with random declaration must be in the range 0.0 <= value <= 1.0. This value represents the percentage of the time that the event is intended to occur.
A gate which uses the random probability feature must be operated in parallel with another gate which has a common event driving input. Both these gates should have the same timing distributions associated with them. When the common input changes state, a probability trial is performed. If the probability value is less than or equal to the value specified in the random declaration, the gate containing the random declaration will have its priority temporarily upgraded and its outputs will change state before the outputs of the other gate. This feature gives the user some level of control (on a percentage basis) over which gate will process the input data first.
As an example, a system which models a communication channel that corrupts 1% of the data bytes that pass through it is shown below:
![]() |
model main(in, out) trans1: good(in, out) trans2: bad(in, out) gate good(in, out) t: delta=1.0e-6 i: in>0x00 o: out=in in=0x00 gate bad(in, out) t: delta=1.0e-6 + random=0.01 i: in>0x00 o: out=0xFF in=0x00 |
The netlist describes a system where ASCII characters are represented by 0x01-0x7F. The value 0x00 indicates there is no data in the channel and the value 0xFF indicates a corrupted character. It is assumed that there is an external data source which supplies characters to the channel input. It should be noted that the random declaration is placed on only one of the two gate descriptions rather than both of them. Unpredictable events occur if the random declaration is placed on both gate descriptions.
The fanout statement is used to selectively enable/disable fanout calculations for a gate when the database is being compiled. The format for a fanout statement is shown below:
Format: | fanout = on |
or: | fanout = off |
When fanout calculation is enabled (the default setting for all gates), the simulator scans the database and determines the total load that the gate is driving. It then multiplies the gate timing parameters by an amount proportional to the load. If an inverter gate was found to have a propagation delay time of 1 nanosecond when driving a single inverter input, an instance of that gate would have a propagation delay time of 3 nanoseconds if it was driving a load equivalent to 3 inverter inputs.
If fanout calculation is turned off for a gate primitive, fanout calculations for all instances of that gate will be ignored. This feature allows the user to force switching times to a particular value and not have them modified by the simulator at run time.
The load statement is used to set the relative loading (capacitance) for an input or output signal. The format of a load statement is shown below:
Format: | load signal1 = value { signal2 = value ... } |
Example: | load in1=2.0 in2=1.5 in3=1.95 |
load sa=2.5 |
The value associated with the signal represents the relative capacitance of the simulation node. When the timing parameters are specified for a gate description, it is assumed that they are chosen for the situation where the gate is driving a single (1.0) unit load such as a minimum size inverter input. The load command tells the simulator that some input structures are smaller or larger (more capacitive) than the reference standard. The simulator, by default, assumes that all signals associated with gate primitives have a load rating of 1.0 (unit load) unless they are overridden by a load statement.
The priority statement is used to establish the scheduling priority for a gate primitive. The format for a priority statement is shown below:
Format: | priority = level |
Example: | priority = 1 |
priority = 7 |
In the event that two gates are scheduled to update their outputs at exactly the same time, the gate with lowest priority level will be processed first. All gate primitives are assigned a default priority of 1 unless they contain random timing declarations in the gate description. In this case the primitive is assigned a default priority of 2. This base priority can be temporarily upgraded to a value of -1 if a random trial is successful during the course of a simulation run. The user is advised to leave the priority settings at their default values unless there is a specific requirement which demands priority readjustment.
The set statement is used to initialize signals to specific logic states before the simulation run takes place. The format for the set statement is shown below:
Format: | set signal1 = <state> @ { <strength> } |
signal2 = <state> @ { <strength> } | |
Example: | set input1=H@2 input2=L input3=X@0 |
set count=4 multiplier=5 divisor=7@2 |
If the user does not specify a strength value, the signal will be assigned a default logic strength of 3 (VDD). This default setting will override any gate output (because the default strength of 2 is used for gate outputs).
The user will find this feature useful in situations where some of the inputs to a logic gate need to be set to a fixed state for the entire duration of the simulation run. For example, the set and reset inputs of a flip flop should be tied low if these inputs are not being driven by any logic circuitry. All instances of a gate entity which contains a set statement will have their corresponding simulation nodes set to the desired state.
The function entity is headed by a function declaration statement that gives a name and a list of exports (which are referenced in a higher level model description). The format of this statement is shown below:
Format: | function name(signal1, signal2, signal3, ... signalN) |
Example: | function JK_FF(ck, j, k, out) |
function DFFLOP(data_in, clk, data_out) | |
function BUS_TO_STATE(b7,b6,b5,b4,b3,b2,b1,b0, output) | |
function STATE_TO_BUS(input, b7,b6,b5,b4,b3,b2,b1,b0) |
The name refers to a Java method, which will find the signal parameters in the same order that they appear in the argument list. The only four functions currently available are listed above. There are two flip-flops (JK and D) and two numeric converters that translate between a bus of 8 signals and a composite hexadecimal digit.
The i: and o: statements which follow the function declaration are used to tell the simulator which signals are responsible for driving the function and which drive other events. If any signal in the event driving list changes state, the function is called and the output values are recalculated. The format of an i: statement, which contains a list of event driving inputs, is shown below:
Format: | i: signal1 signal2 signal3 ... signalN |
Example: | i: b7 b6 b5 b4 b3 b2 b1 b0 |
i: input phi phi_bar set reset |
The format of an o: statement which contains a list of output ports is shown below:
Format: | o: signal1 signal2 signal3 ... signalN |
Example: | o: out1 out2 out3 |
o: q q_bar |
Just as there are special statements that affect the operating characteristics of a gate entity, so are these statements available to direct the function entity. The t: statement is used to set the time delay between input and output changes. The load statement is used to set the relative loading (capacitance) for the input and output ports. The priority statement is used to establish the scheduling priority. The set statement is used to initialize signals to specific logic states before the simulation run takes place. The format of these statement is identical to that of the gate entity. Note that the Java method does not have to use the values specified in these statements and can schedule events with values that are specified directly inside the code.
The specification for a 3 bit shift register (edge triggered) is shown below. This circuit uses a function primitive to model the operation of a D flip-flop:
model main(input, ck, q2, q1, q0) stage0: DFFLOP(input, ck, q0) stage1: DFFLOP(q0, ck, q1) stage2: DFFLOP(q1, ck, q2) function DFFLOP(data_in, clock, output) i: clock o: output t: delta=10e-9 load clock=2.0It should be noted that the clock is the only event driving input for the flip-flop function. There is no need to call the function if the signal "data_in" will be sampled only when the event driving signal ("clock") changes state. The designer can write the function so that it samples the data only when the function is called and the clock input is asserted high (rising edge triggered). If the clock signal is low when the function is called (falling clock edge) the procedure can ignore the data and return control back to the simulation program.
The calling arguments to the Java method are set up as a linked list of signal pointers. The simulator places the arguments into this list in the same order that they appear in the declaration of the function entity. The programmer requires some knowledge of the internals of the simulator to extract the correct information from this list and to schedule new events. A complete discussion of function entity programming is beyond the scope of this document.
The model entity is headed by a model declaration statement and followed by a body which references instances of other entities, lower in the hierarchy. The model name and a list of exports (which are referenced in a higher level model description) are included in this statement. The format of the model declaration statement is shown below:
Format: | model name(signal1, signal2, signal3, ... signalN) |
Example: | model dff(d, ck, set, reset, q, q_bar) |
model shift_reg(input, ck, q3, q2, q1, q0) |
References to instances of primitive objects (gates and functions) and lower level models are used to describe the topology of the new model to the simulator. The format of an instance reference statement is shown below:
Format: | instance : model ( signal1, signal2, signal3, ... signalN ) |
Example: | gate1: subgate(input, en, mix) |
node5: inverter(mix, out_bar) |
It should be noted each instance reference in a model entity must have a unique instance name. The following is an example of the use of a model entity:
model latch(input, en, en_bar, out) gate1: xgate(input, en, mix) gate2: xgate(out, en_bar, mix) gate3: inverter(mix, out_bar) gate4: inverter(out_bar, out) gate xgate(in, ctl, out) t: delta=8.0e-9 t: delta=8.0e-9 i: ctl=L o: out=X@0 i: ctl=H in=L o: out=L i: ctl=H in=H o: out=H i: o: out=X@2 gate inverter(in, out) t: delta=5.0e-9 i: in=L o: out=H i: in=H o: out=L i: o: out=X@2This example contains the description of a simple latch. When the enable signal is asserted high (en=H, en_bar=L) the input data passes through the transmission gate (gate1) and then through two inverters where it eventually reaches the output. When enable is asserted low (en=L, en_bar=H) the input connection is broken and the feedback transmission gate (gate2) is turned on. The state of the latch is preserved by this feedback path.
The set statement is used to initialize signals within the model description to specific logic states before the simulation run takes place. This feature is useful for tying unused inputs to power(H) or ground(L).
![]() |
9-6-1: Introduction to Routing |
![]() |
Some of these routers make use of the "Unrouted Arc", a thin-line arc that can connect any two components. Creating "rats nests" of these arcs forms a graphical specification that the router can use. The unrouted arc is from the Generic Technology (see Section 7-6-3). To create one, use the Get Unrouted Wire command (in menu Tool / Routing). Then use standard wiring commands to run the unrouted arc. Another way to get unrouted wires is to select all or part of an existing route (made with any arc) and use the Unroute command.
Finally, the Copy Routing Topology and Paste Routing Topology commands can be used to create unrouted arcs in one cell (the "pasted" cell) where there are connections of any kind on another cell (the "copied" cell). The Paste Routing Topology command uses node and arc names to associate the two cells.
The auto-stitcher places a wire when all of these conditions are met:
To run the auto-stitcher, use the Enable Auto-Stitching command (in menu Tool / Routing ). The router will make all necessary connections, and incrementally add wires as further changes are made to the circuit. To stop stitching, select the menu entry again to uncheck it. To run the auto-stitcher only once for the current cell, use Auto-Stitch Now To run it once, and in the highlighted area only, use the Auto-Stitch Highlighted Now command. Note that this auto-stitches all cell instances that intersect the highlighted area, so even if only a portion of a cell falls into the highlighted area, the entire cell is stitched.
![]() | The auto-stitcher allows you to specify a particular type of wire to use in routing. By default, the router figures out which wire to use. However, in the "Routing" preferences (in menu File / Preferences..., "Tools" section, "Routing" tab) a specified wire can be given (or automatic selection can be resumed by selecting the "DEFAULT ARC" entry). |
To control the wiring of arrays of cells more directly, there is the mimic-stitcher. This tool lets the designer place a wire between two cells, and then it adds other wires between all other similarly configured cells in the circuit. Thus, it mimics your actions.
Specifically, it mimics all situations where the same ports on the same type of nodes exist, separated by the same distance.
The "Routing" preferences (in menu File / Preferences..., "Tools" section, "Routing" tab) has many useful controls for mimic stitching.
![]() | First, you can request that the mimic stitcher also mimic wire deletions. Second, you can request that the mimic stitcher relax its restriction about mimicing arcs (by allowing the ports to be different, the nodes to be different, or the node sizes to be different). You can also ask the mimic stitcher to work interactively, which causes it to examine all possible restriction sets, offering to route wires with increasingly relaxed acceptance criteria. |
To turn on the mimic-stitcher, use the Enable Mimic-Stitching command (in menu Tool / Routing). To disable the stitcher, use the command to uncheck it. You can also request that the mimic-stitcher run just once (mimicing the very last wire that was created or deleted) by using the Mimic-Stitch Now command. Finally, you can request that the mimic-stitcher run just once, mimicing the currently selected arc, by using the Mimic Selected command.
Note that maze routing is done one wire at a time, and may fail if no path can be found. Therefore it may be preferable to route the unrouted wires one-at-a-time in order to better control the process.
Note also that maze routing constructs an array which is the size of the route, and searches the array for a routing path. Therefore, long wires will use large amounts of memory and time.
For an example of maze routing, open the Samples library and edit the cell "tool-RoutingMaze" (you can read the library with the Load Library command, in menu Help / Samples). This cell has a number of unrouted wires that can be routed.
To specify an intended path for the river-router, every connection must be made with an Unrouted arc. Thus, before river-routing, there should be a series of direct (and presumably nonmanhattan) unrouted arcs. These arcs are replaced with the appropriate geometry during river-routing.
To convert the unrouted wires into layout, use the River-Route command (in menu Tool / Routing). If there are unrouted arcs selected, these will be the only ones converted. Otherwise, all unrouted arcs in the cell will be converted. If it is necessary, nodes may be moved to make room for the river-routed wires.
The river router always routes to the left or bottom side of the routing channel. Thus, if there is a vertical channel that is very wide, the wires will run to the left side and then jog to their proper location there. The only way to force routing to the right or top side is to rotate the entire circuit so that these sides are on the left and bottom.
For an example of river routing, open the Samples library and edit the cell "tool-RoutingRiver" (you can read the library with the Load Library command, in menu Help / Samples).
![]() |
9-7-1: NCC Overview |
![]() |
The Java Electric NCC differs from the C Electric NCC in two signficant ways.
To compare two cells, use these commands (in menu Tool / NCC):
We recommend hierarchical over flat comparison because hierarchical comparisons are faster and the mismatch diagnostics are much more precise and intelligible. However, transistor size checking of schematics with automatically sized transistors does not work with hierarchical comparisons. If you select "Check transistor sizes" and your schematics include automatically sized transistors you must also select "Flat Comparison".
The best way to use NCC is to initially perform all your comparisons hierarchically. This will typically require many iterations. Once you have gotten your designs to pass hierarchical comparison, turn on size checking and flat comparison. This will report transistor size mismatches.
NCC does the following when size checking is enabled. After each topological comparison, NCC checks if it found any topological mismatches. If NCC found no mismatches then NCC checks, for each pair of matching transistors, that the widths and lengths are approximately equal.
The two tolerance boxes allow the user to specify how much more the larger of the two matched transistors may be than the smaller before NCC reports a size mismatch. The "Relative size tolerance" box specifies the difference in percentage. The "Absolute size tolerance" box specifies the difference in units. NCC reports a size mismatch when both tolerances are exceeded.
If you enable "Size Checking" and "Hierarchical Comparison" simultaneously then NCC restricts which Cells it treats hierarchically to ensure a correct answer in the presence of automatically sized transistors. For this case it compares a pair of Cells hierarchically if and only if each Cell is instantiated exactly once.
However, it is occasionally useful to continue checking even after mismatches have been detected. For example, the designer might find that although cell ABC mismatches, she is unable to fix ABC because someone else designed it. When asked to continue, NCC will do the following when comparing cells that use ABC:
The check box "Don't recheck cells that have passed in this Electric run" skips the checking of a pair of cells if they have ever passed in this run of Electric. Because this command is not smart enough to recheck the cells after either have changed, this command is of very limited utility. At the moment NCC has run sufficiently fast that it doesn't seem worth the effort to implement anything more sophisticated.
NCC allows the designer to add the annotation: exportsConnectedByParent to the cell to inform NCC which exports will be connected by the parent. The keyword is followed by a list of strings and/or regular expressions. A string matches an export name exactly, for example: vdd. Thus A{lay} can contain the NCC annotation:
exportsConnectedByParent vdd vdd_1 vdd_2
Alternatively, the designer can use regular expressions. Regular expressions begin and end with the character: '/'. Thus A{lay} can contain the NCC annotation:
exportsConnectedByParent vdd /vdd_[0-9]+/
When NCC compares a cell with an exportsConnectedByParent annotation it performs the comparison as if those exports were connected. It is safe for NCC to believe this annotation because NCC also checks the assertion. When NCC encounters an instance of a cell with an exportsConnectedByParent annotation NCC reports an error whenever that assertion isn't satisfied.
The skipNCC annotation should be added to a cell, say B, when:
All the characters following the keyword to the end of the line serve as a comment. This is useful for documenting why this annotation was necessary. When you ask NCC to compare every cell in the design, NCC will tell you which cells it is skipping and why. For example, if cell B includes the NCC annotation:
skipNCC layout is missing ground connection
then NCC will print:
Skipping NCC of A because layout is missing ground connection.
A common reason for needing this annotation is an unfortunate situation: the exports of B{sch} and B{lay} don't match. A skipNCC on B prevents NCC from reporting export mismatches because 1) cell B is not checked by itself and 2) when a parent of cell B is checked, B's exports are discarded when NCC flattens through cell B. Although not always possible, it's better to fix export mismatches, because fixing them will yield clearer mismatch diagnostics when there is a problem.
Hierarchical NCCs do not require a perfect match between the schematic and layout hierarchies. Instead, hierarchical NCC uses heuristics to determine which cell instances must be flattened and which can be compared hierarchically. The heuristic sometimes make mistakes. When that happens, the flattenInstances annotation can guide the heuristic.
The list of strings and/or regular expressions are used to match instance names within the cell. Those cell instances that match are always flattened.
The designer should add the notSubcircuit annotation to a cell, say B, if:
When hierarchical NCC encounters a notSubcircuit annotation it prints a message that includes the comment in a manner similar to skipNCC.
The notSubcircuit annotation only affects hierarchical NCCs, it is ignored by flat NCCs.
The designer should add a joinGroup annotation to, say, cell B if NCC should behave as if cell B belonged to a different cell group and that cell group is in a different library. The cell group to move B to is that cell group that contains <cell name>. That specification should be fully qualified: library:cell{view}.
Memberships in cell groups is important when NCC performs hierarchical comparisons because NCC assumes that cells in the same cell group are supposed to be topologically identical. Membership of two cells in the same cell group is one criteria NCC uses to decide that it should treat them as hierarchical entities and it should compare them separately.
Occasionally it is impractical to place the layout and schematic views of a cell in the same cell group. For example when layout is automatically generated from hand drawn schematics it may be better to place the layout in a different library than the schematics.
Don't compare the Cells in this Cell group; just assume they are topologically equivalent.
The blackBox is useful when a particular arrangement of layout geometry implemements a construct that Electric doesn't understand. For example, we have used this construct to handle resistors and parasitic bipolar transistors in the layout.
![]() |
9-8-1: Pad Frame Generation |
![]() |
The format of the pad frame disk file is as follows:
celllibrary LIBRARYFILE [copy] | ; Identifies the file with the pads |
cell PADFRAMECELL | ; Creates a cell to hold the pad frame |
core CORECELL | ; Places cell in center of pad frame |
align PADCELL INPUTPORT OUTPUTPORT | ; Defines input and output ports on pads |
export PADCELL IOPORT [COREPORT] | ; Defines exports on the pads |
place PADCELL [GAP] [PORTASSOCIATION] | ; Places a pad into the pad frame |
rotate DIRECTION | ; Turns the corner in pad placement |
The file must have exactly one celllibrary
and cell
statement,
as they identify the pad library and the pad frame cell.
If the celllibrary
line ends with the keyword copy
,
then cells from that library are copied into the library with the pad ring (by default, they are merely instantiated,
creating a cross-library reference to the pads library).
The file may have only one core
statement to place your top-level circuit inside of the pad frame.
If there is no core
statement,
then pads are placed without any circuit in the middle.
The align
statement is used to identify connection points on the pads that will be used for placement.
Each pad should have an input and an output port that define the edges of the pad.
These ports are typically the on the power or ground rails that run through the pad.
When placing pads, the output port of one pad is aligned with the input port of the next pad.
Each pad that is placed with a place
statement is aligned with the previous pad according to the alignment factor.
A gap
can be given in the placement that spreads the two pads by the specified distance.
For example, the statement:
place padIn gap=100
If a core cell has been given, you can also indicate wiring between the pads and the core ports.
This is done by having one or more port associations in the place
statements.
The format of a port association is simply PADPORT = COREPORT
.
For example, the statement:
place padOut tap=y
The port association can also create an export on the pad. The statement:
place padOut export io=o7 export tap=core_o7
name
keyword in conjunction
with exports defined for the pad at the start of the file. For example, defining the IO ports as
export padOut io tap
place padOut name=o7
The rotate
statement rotates subsequent pads by the specified amount.
The statement has only two forms: rotate c
to rotate clockwise,
and rotate cc
to rotate counterclockwise.
Here is an example of a pad frame disk file, with the finished layout. There is a cell in the Samples library called "tool-PadFrame" (get it with the Load Library command, in menu Help / Samples). Suppose a text file is created with with this content, and read with the Pad Frame Generator... command (in menu Tool / Generation).
; specify library with pads | ; place the top edge of pads |
celllibrary pads4u.txt | place PAD_corner{lay} |
place PAD_gnd{lay} gnd_in=gnd | |
; create a cell called "padframe" | place PAD_vdd{lay} m1m2=vdd |
cell padframe | |
; place the right edge of pads | |
; place this cell as the "core" | rotate c |
core tool-PadFrame | place PAD_corner{lay} |
place PAD_in{lay} out=pulse | |
; set the alignment of the pads | place PAD_spacer{lay} |
; (with input and output export) | |
align PAD_in{lay} dvddL dvddR | ; place the bottom edge of pads |
align PAD_out{lay} dvddL dvddR | rotate c |
align PAD_vdd{lay} dvddL dvddR | place PAD_corner{lay} |
align PAD_gnd{lay} dvddL dvddR | place PAD_out{lay} in=out1 |
align PAD_corner{lay} dvddL dvddR | place PAD_out{lay} in=out2 |
align PAD_spacer{lay} dvddL dvddR | |
; place the left edge of pads | |
rotate c | |
place PAD_corner{lay} | |
place PAD_in{lay} out=in1 | |
place PAD_in{lay} out=in2 |
![]() |
This file places 8 pads in a ring (2 on each side) and also places corner "pads" for making bends.
The input pads connect to the 2 input ports "a1" and "a2".
The output pads connect to the 3 output ports "out1", "out2", and "out3"
The power and ground pads connect to the "vdd" and "gnd" ports.
Note that the generator places pad instances, but does not wire them to each other. In order to create a uniform ring of power and ground between the pads, you can use the Auto-router or the Mimic-router (see Section 9-6-1). |
Connections between pads and ports of the core cell use Unrouted arcs (from the Generic technology, see Section 7-6-3). After these connections are routed with real geometry, the finished layout is shown here, fully instantiated. | ![]() |
1
010101
011001
100101
101010
4
00000000
10000000
01000000
11000000
f = (a and b and (not c)) or ((not b) and (not a)) |
g = (a and c) or ((not a) and (not c)) |
4 3 1 1 0 0 0 X 1 X 1 0 X 0
![]() |
9-9: Logical Effort |
![]() |
To control Logical Effort, use the "Logical Effort" preferences (in menu File / Preferences..., "Tools" section, "Logical Effort" tab). This lets you control a number of settings for Logical Effort analysis.
A design that is intended to be analyzed with Logical Effort must be composed of special Logical Effort gates. A Logical Effort gate is simply a schematic or layout cell that conforms to the following specifications:
On the input and output exports of the cell, we can define an attribute named "le" (double-click on the export text to get the Export Properties dialog, then click the Attributes button to define the attribute). The value of this attribute is the logical effort of that port. For example, a NAND gate typically has a logical effort on each input of 4/3, and an output logical effort of 2. An inverter is defined to have an input logical effort of 1, and an output logical effort of 1.
The size assigned to the logical effort gate is retrieved via the "LE.getdrive()" call. This value can then be used to size transistors within the gate. The size retrieved is scaled with respect to a minimum sized inverter (as are all other logical effort parameters). So a size of "1" denotes a minimum sized inverter.
While these attributes are defined on the layout or schematic cell definition, they must also be present on the instantiated icon or instance of that definition. By default this will be so.
Finally, there must be at least one load that is driven by the gates in order for them to be sized. A load is either a transistor or a capacitor. Gates that do not drive loads, or that do not drive gates that drive loads, will not be assigned sizes.
Electric comes with a set of libraries that are specially designed for Logical Effort. Use the Load Logical Effort Libraries (Purple, Red, and Orange) command (in menu Tool / Logical Effort) to read these libraries.
There are several advanced features that may be added to the cell definition:
These commands may be given to the Logical Effort tool (in menu Tool / Logical Effort):
![]() |
9-10-1: Parasitic Extraction |
![]() |
The Parasitic Extraction tool is used by netlisters and other parts of the system that need to know about geometric factors. To control Parasitic Extraction, use the "Parasitic" preferences (in menu File / Preferences..., "Tools" section, "Parasitic" tab).
Each layer of the current technology is listed, and you can set its unit resistance, area capacitance, and edge capacitance. In addition, you can set minimum resistance and capacitance values for the entire technology.
The bottom section controls values for the entire technology. You can set the minimum resistance and capacitance for the entire technology. The "Gate Length Shrink" is a compensation factor for gate lengths. Some process technologies shrink the gate length by a fixed amount. "Include Gate In Resistance" requests that a transistor's gate area be included in overall area calculations for resistance determination. "Include Ground Network" requests that ground networks be analyzed.
Because Electric captures connectivity information during design, there is no need for "node extraction", the process of extracting connectivity from layout. However, there are situations where a circuit has only layout and no connectivity, specifically when a circuit has been read into Electric from CIF, GDS, or other formats that have no connectivity information in them.
When CIF, GDS, and other foreign file formats are read into Electric, the cells they create are composed entirely of pure-layer nodes (see Section 6-10-1). These nodes appear to represent the circuit correctly, and can even be written back out to CIF or GDS correctly. But the missing connectivity information means that Electric cannot properly analyze these circuits (cannot do DRC, simulation, etc.)
The solution is to convert this geometry into properly connected components. To convert the current cell into connected geometry, use the Extract Current Cell command (from menu Tool / Network). To convert the current cell and all subcells, use the Extract Current Hierarchy command. Electric creates new versions of the layout cells that have higher-level nodes and arcs in them.
Although the process of converting layout into connectivity information is difficult, it can usually be done correctly. In Electric, this process is complicated by the fact that the resulting connectivity information must be expressed as a set of "high-level" primitives (transistors and contacts) which have their own ways of appearing in the layout. Therefore, it is not always possible to extract layout precisely. For example, if the design rules for a transistor require that polysilicon extend beyond the gate area by 2 units, the transistor primitive for that technology will have this extra geometry built into it. But what would happen if the geometry to be extracted extends by 3 units? Electric adds an extra 1-unit arc to fill-out the extra geometry that it finds. Worse yet, what would happen if the geometry extends by only 1 unit? Electric simply cannot represent this with its primitives. It will create the transistor, but it will no longer match the original geometry. In general, the system attempts to create high-level primitives that mimic the original geometry. It often leaves small pure-layer nodes behind to complete the extraction. As an aid in debugging the extraction process, these extra pure-layer nodes are highlighted in the resulting cell.
![]() |
Two "Network" preferences are available to control the extraction process
(in menu File / Preferences..., "Tools" section, "Network" tab).
The first is "Force exact cut placement", which requires that the cut (or via) locations appear exactly in the same place once extracted. Without this preference, Electric will find contact areas and replace them with contact nodes regardless of where the contact nodes place the cuts. With this preference selected, Electric will place contact nodes in such a way that the cut layers land in the correct original locations. |
The disadvantage of forcing exact cut placement is that Electric will create many contact nodes, one for each cut layer. In multi-cut situations, this may be many more nodes than are necessary.
The other preference is "Grid-align geometry before extraction". Doing this makes the extraction process run more smoothly, but may cost slightly in accuracy.
![]() |
9-11: Compaction |
![]() |
To compact, use the Do Compaction command (in menu Tool / Compaction).
The "Compaction" preferences (in menu File / Preferences..., "Tools" section, "Compaction" tab).
can tell the compactor to expand the circuit if it is too close for the design rules.
For an example of compaction, open the Samples library and edit the cell "tool-Compaction" (you can read the library with the Load Library command, in menu Help / Samples). | ![]() |
Be warned that the compaction tool is experimental and doesn't always achieve optimal results.
![]() |
9-12: Silicon Compiler |
![]() |
Be warned that the silicon compiler is rather old, and so it produces layout that alternates standard cell rows and routing rows. Modern silicon compilers use multiple metal processes to route over the standard cells, but this system does not. This system uses two layers: a vertical routing arc to run in and out of cells, and a horizontal routing arc to run between the cells in the routing channel. It also uses power arcs to bring power and ground to the cell rows, and main power arcs to connect the rails on the left and right.
The VHDL description is normally placed in the "vhdl" view of a cell (see Section 4-10 for more on text editing). There is a VHDL example in cell "tool-SiliconCompiler{vhdl}" of the "samples" library. To access it, use the Load Library command (in menu Help / Samples).
To convert a schematic or VHDL cell into layout, use the Convert Current Cell to Layout command (in menu Tools / Silicon Compiler). To compile VHDL to the {net.quisc} view, use the Compile VHDL to Netlist View command (this is typically not needed, since the previous command does it automatically).
When creating a schematic or VHDL cell to be compiled, it is important to know what primitives are available in the standard cell library. Electric comes with a CMOS cell library in the MOSIS CMOS ("mocmos") technology. This library is not correct, and exists only to illustrate the Silicon Compiler. These component declarations are available:
component and2 port(a1, a2 : in bit; y : out bit); end component;
component and3 port(a1, a2, a3 : in bit; y : out bit); end component;
component and4 port(a1, a2, a3, a4 : in bit; y : out bit); end component;
component inverter port(a : in bit; y : out bit); end component;
component nand2 port(a1, a2 : in bit; y : out bit); end component;
component nand3 port(a1, a2, a3 : in bit; y : out bit); end component;
component nand4 port(a1, a2, a3, a4 : in bit; y : out bit); end component;
component nor2 port(a1, a2 : in bit; y : out bit); end component;
component nor3 port(a1, a2, a3 : in bit; y : out bit); end component;
component nor4 port(a1, a2, a3, a4 : in bit; y : out bit); end component;
component or2 port(a1, a2 : in bit; y : out bit); end component;
component or3 port(a1, a2, a3 : in bit; y : out bit); end component;
component or4 port(a1, a2, a3, a4 : in bit; y : out bit); end component;
component rdff port(d, ck, cb, reset : in bit; q, qb : out bit); end component;
component xor2 port(a1, a2 : in bit; y : out bit); end component;
The "Silicon Compiler" preferences (in menu File / Preferences..., "Tools" section, "Silicon Compiler" tab) let you control many aspects of placement and routing.
![]() |
10-1: JELIB File Format |
![]() |
JELIB files are text-readable files. Each line of a JELIB file starts with an identifying character that distinguishes the line. Blank lines, and those that start with the comment identifying character (#) are ignored. There is no limit to the length of a line of text.
After the identifying character at the start of a line, there are a set of fields. All of the fields are separated by the separator character (|) except for the first field, which begins immediately after the identifying character. No blank spaces are allowed on a line (that is, any blank spaces are treated as valid characters). Control characters (such as the identifying characters) must be upper case. In order to insert a '|' or '\n' or '\r' into a field, it must be enclosed in the quotation mark characters ("). Backslash character can be used inside enclosed strings to denote special characters:
Characters | Meaning |
---|---|
\n | line feed character (\n) |
\r | carriage return character (\r) |
\" | quotation mark character (") |
\\ | backslash character (\) |
Each of the different types of lines in the file has a fixed set of fields that must appear. Some line types also allow additional fields at the end to add variables (attribute/value pairs, see Section 10-4-1).
The JELIB file has 3 parts: the header, cells, and trailer.
The header has these elements:
H | Header information; variable fields are allowed |
V | View information |
L | External library information |
R | External cell in the above external library |
F | External export in the above external cell |
T | Technology information; variable fields are allowed |
D | Primitive Node information in the above technology |
P | Primitive Port information in the above primitive node |
W | Primitive Arc information in the above technology |
O | Tool information |
The cells have these elements:
C | Cell header; variable fields are allowed |
N | Primitive node information in the current cell; variable fields are allowed |
I | Cell instance information in the current cell; variable fields are allowed |
A | Arc information in the current cell; variable fields are allowed |
E | Export information in the current cell; variable fields are allowed |
X | Cell termination |
The trailer has this element:
G | Group information |
Everything in the file is completely ordered. There is an ordering to the external libraries, cells in those libraries, technologies, tools, cells, nodes/arcs/exports in a cell, etc. Even the extra variables on a line are ordered. The ordering is usually a name sort. By ordering everything in the file, the exact same file is generated every time, and source-code comparison operations will accurately find differences between two files. Note, however, that the JELIB reader does not require any sorting, and can handle the data in any order.
![]() |
10-2-1: Header, View, and Tool |
![]() |
The first line in the JELIB file should be the "H" header line. The syntax is:
H<name> | <version> [ | <variable> ]* | |
<name> | the name of the library. |
<version> | the version of Electric that wrote the library. |
<variable> | a list of variables on the library (see Section 10-4-1). |
The name of the library is used in the JELIB file to identify references to this library. The actual name of this library is obtained from the file path of this JELIB file.
Example:
Hlatches|8.01
Declares that library "latches" was written from Electric version 8.01.
All views used in the library must be declared.
V<full name> | <name> | |
<full name> | the full name of the view. |
<name> | the abbreviation name of the view. |
Example:
Vlayout|lay
Declares view with abbreviation name "lay" and full name "layout".
There is no need to declare all tools in the header. The only reason for a tool declaration to exist is if the tool has preferences variables stored on it. If there are multiple tool lines, they are sorted by the tool name. The syntax is:
O<name> [ | <variable> ]* | |
<name> | the name of the tool. |
<variable> | a list of preferences on the tool (stored as variables, see Section 10-4-1). |
Example:
Osimulation|SpiceEngine()I2|SpiceLevel()I1
Declares two preferences on the “simulation” tool object. The first is called “SpiceEngine” and is set to the integer value 2. The second is called “SpiceLevel” and is set to the integer value 1.
The syntax of an external library reference is:
L<name> | <path> | |
<name> | the name of the external library. |
<path> | the full path to the disk file with the library. |
The name of the library is used in JELIB file to references to this library. The actual name of this library is obtained from the path.
The syntax of an external cell reference is:
R<name> | <lowX> | <highX> | <lowY> | <highY> | <creation> | <revision> | |
<name> | the name of the external cell. |
<lowX> | the low X bounds of the cell contents. |
<highX> | the high X bounds of the cell contents. |
<lowY> | the low Y bounds of the cell contents. |
<highY> | the high Y bounds of the cell contents. |
<creation> | the creation date of the cell (Java format). |
<revision> | the revision date of the cell (Java format). |
The Java format for dates (the creation and revision dates) is in milliseconds since the "epoch" (Midnight on January 1, 1970, GMT).
The syntax of an external export reference is:
F<name> | <centerX> | <centerY> | |
<name> | the name of the external export. |
<centerX> | the X coordinate of the center of export polygon. |
<centerY> | the Y coordinate of the center of export polygon. |
Examples:
Lspiceparts|/home/strubin/electric/spiceparts.jelib
Rgate;1{sch}|-4|4|0|2|1092185029000|1092185060000
Fout|0|2
Declares that an external library called "spiceparts" will be used by the current library, and that it can be found at "/home/strubin/electric/spiceparts.jelib". In that library is a cell called "gate;1{sch}" whose contents run from –4 to 4 in X and 0 to 2 in Y. In that cell is an export called "out" with center at (0,2).
All technologies used in the library must be in the header. The other reason for a technology declaration to exist is if the technology has preferences stored on it. If there are multiple technology lines, they are sorted by technology name. The syntax is:
T<name> [ | <variable> ]* | |
<name> | the name of the technology. |
<variable> | a list of preferences on the technology (stored as variables, see Section 10-4-1). |
Examples:
Tmocmos
Declares that there should be a technology called "mocmos".
Tmocmos|ScaleFORmocmos()D200
Declares the technology "mocmos" and also creates a preference on that technology object called "ScaleFORmocmos" which is a double-precision value equal to 200.
![]() |
10-3-1: Cells |
![]() |
C<name> | <tech> | <creation> | <revision> | <flags> [ | <variable> ]* | |
<name> | the name of the cell in the form "NAME;VERSION{VIEW}". |
<tech> | the technology of the cell. |
<creation> | the creation date of the cell (Java format). |
<revision> | the revision date of the cell (Java format). |
<flags> | flags for the cell. |
<variable> | a list of variables on the cell (see Section 10-4-1). |
The Java format for dates (the creation and revision dates) is in milliseconds since the "epoch" (Midnight on January 1, 1970, GMT).
The <flags> field consists of any of the following letters, (sorted alphabetically):
"C" if this cell is part of a cell-library.
"E" if the cell should be created "expanded".
"I" if instances in the cell are locked.
"L" if everything in the cell is locked.
"T" if this cell is part of a technology-library.
Example:
CrxArray;1{lay}|mocmos|1092185029000|1092185060000|I
Declares cell "rxArray{lay}", version 1, associated with the "mocmos" technology. The cell was created at date 1092185029000 and last modified at date 1092185060000. All instances in the cell are locked.
N<type> | <name> | <nameTD> | <x> | <y> | <width> | <height> | <orientation> | <flags> [ | <variable>> ]* | |
I<type> | <name> | <nameTD> | <x> | <y> | <orientation> | <flags> | <TD>> [ | <variable> ]* | |
<type> | the type of the node instance. For primitive node instances, this has the form: [<technology>:]<primitive-node>. If <technology> is omitted, the technology of the cell is assumed. For cell instances, it has the form: [<library>:]<cell>;<version>{<view>}. If <library> is omitted, the library defined by this JELIB file is assumed. |
<name> | the name of the node instance. If there are multiple nodes with the same name, then the name is quoted, and a unique integer follows the close quote. |
<nameTD> | a text descriptor for the name (when displayed). |
<x> | the X coordinate of the anchor point of the node instance. |
<y> | the Y coordinate of the anchor point of the node instance. |
<width> | the width of the primitive node (must be non-negative). |
<height> | the height of the primitive node (must be non-negative). |
<orientation> | the orientation of the node (see below). |
<flags> | flags for the node instance (see below). |
<TD> | a text descriptor for the cell instance name (does not apply to primitives). |
<variable> | a list of variables on the node instance (see Section 10-4-1). |
The <orientation> field consists of any of the following letters, with an optional numeric part at the end:
"X" if the node instance is X-mirrored (mirrored about Y axis).
"Y" if the node instance is Y-mirrored (mirrored about X axis).
"R" each letter rotates the node instance at 90 degrees counter-clockwise.
Num Any digits at the end are additional rotation in tenths of a degree.
The <flags> field consists of any of the following letters, sorted alphabetically, with the numeric part at the end:
"A" if the node instance is hard-to-select.
"E" if the node instance is "expanded".
"L" if the node instance is locked.
"V" if the node instance is visible only inside the cell.
"W" if the node instance is wiped (covered by an arc, so no need to draw).
Num Any digits at the end are the technology-specific bits.
Examples:
Nschematic:Transistor|mos@0||2|0|4|4|R|2|ATTR_length(D5G0.5;X-0.5;Y-1;)S2
Places a schematic Transistor called "mos@0" at (2,0), size 4x4, rotated 90 degrees. The flag field "2" is numeric, and therefore is technology-specific information (in this case, it makes the transistor be pMOS). There is one attribute on the node, called "length", with the value "2" (a string). This attribute is displayed, anchored at its center ("D5"), is 1 half grid unit in size ("G0.5;"), and is offset (-0.5, -1) from the node center ("“X-0.5;Y-1;").
Ilow;1{lay}|"HAPPY"1||14|12|Y|E|D5G4;
Places an instance of cell "low{lay}" from the library defined in this JELIB file. The instance is named "HAPPY" (the name field is "HAPPY"1 which means this is the first instance with this name). It is at (14,12),mirrored in Y, and is rotated 0. The "E" means that the node is expanded, but when it is unexpanded, its name is described by D5G4; (D5 means a centered anchor point, G4; means size 4 units).
A<type> | <name> | <nameTD> | <width> | <flags> | <headNode> | <headPort> | <headX> | <headY>> | <tailNode> | <tailPort> | <tailX> | <tailY>> [ | <variable> ]* | |
<type> | the type of the arc instance. It has the form: [<technology>:]<arc>. If technology is omitted, the technology of the cell is assumed. |
<name> | the name of the arc instance. |
<nameTD> | a text descriptor for the name (when displayed). |
<width> | the width of the arc instance. |
<flags> | flags for the arc instance (see below). |
<headNode> | the name of the node at the head of the arc instance. |
<headPort> | the name of the port on the head node (may be blank if there are no choices). |
<headX> | the X coordinate of the head of the arc instance. |
<headY> | the Y coordinate of the head of the arc instance. |
<tailNode> | the name of the node at the tail of the arc instance. |
<tailPort> | the name of the port on the tail node (may be blank if there are no choices). |
<tailX> | the X coordinate of the tail of the arc instance. |
<tailY> | the Y coordinate of the tail of the arc instance. |
<variable> | a list of variables on the arc instance (see Section 10-4-1). |
The <flags> field consists of any of the following letters, sorted alphabetically, with the numeric part at the end:
"A" if the arc instance is hard-to-select.
"B" if the arc instance has an arrow line on the body (use "X" and "Y" for arrow heads).
"F" if the arc instance is NOT fixed-angle (fixed-angle is more common).
"G" if the arc instance has its head connection negated.
"I" if the arc instance has its head NOT extended.
"J" if the arc instance has its tail NOT extended.
"N" if the arc instance has its tail connection negated.
"R" if the arc instance is rigid.
"S" if the arc instance is slidable.
"X" if the arc instance has an arrow on the head (use "B" for an arrow body).
"Y" if the arc instance has an arrow on the tail (use "B" for an arrow body).
Num Any digits at the end are the angle of the arc (in tenths of a degree).
Examples:
AMetal-1|net@0||3|S1800|contact@0||10|10|pin@0||20|10
Places a metal-1 arc (from the technology of the cell). The arc is named "net@0", is 3 wide, slidable, and at a 180 degree angle. The arc runs from (10,10) on node "contact@0", to (20,10) on node "pin@0".
Aschematic:bus|net@161||1|IJ2700|busHat@4|s[1:8]|42|14|conn@15|y|42|25
Places a bus arc (from schematic) named "net@161"”, width 1, not end-extended on either end, at 270 degrees angle. The bus runs from (42,14) on node busHat@4 (port "s[1:8]") to (42,25) on node "conn@15" (port "y").
E<name> | <TD> | <originalNode> | <originalPort> | <flags> | [ | <variable> ]* | |
<name> | the name of the export. |
<TD> | the text descriptor for writing the port (described later). |
<originalNode> | the name of the node instance in this cell that the export resides on. |
<originalPort> | the name of the port on the exported node instance (may be blank if there are no choices). |
<flags> | flags for the export (see below). |
<variable> | a list of variables on the export (see Section 10-4-1). |
The <flags> field has the format:
<characteristics> [ /A ] [ /B ]
<characteristics> the nature of the export. Choose from the following:
"U" unknown.
"I" input.
"O" output.
"B" bi-directional.
"P" power.
"G" ground.
"C" clock.
"C1" clock phase 1.
"C2" clock phase 2.
"C3" clock phase 3.
"C4" clock phase 4.
"C5" clock phase 5.
"C6" clock phase 6.
"RO" reference output.
"RI" reference input.
"RB" reference base.
/A indicates that the export is always drawn
/B indicates that the export is body-only (no equivalent on the icon)
Example:
Es[18]||conn@14|a|D5G2;|I/B
Exports port "a" of node instance "conn@14"” and calls it "s[18]". The text of the export is attached at the center of the port ("D5") and is 2 units high ("G2;"). It is of type input, and only appears in the contents (not the icon).
![]() |
10-4-1: Variables |
![]() |
<name> ( <TD> ) <type> <value> | |
<name> | the name of the variable. |
<TD> | the text descriptor (when the variable is visible). |
<type> | the type of data attached. |
<value> | the data. If it starts with "[", it is an array of the form [ |
<name> and <value> fields may be enclosed in quotation marks. Backslash character can be used inside enclosed strings to denote special characters.
The <type> field can be one of these:
"B" Boolean ("T" or "F")
Examples:
Adds a variable called "ART_message" with the string "txArray4x4B".
The text descriptor indicates centered text ("D5") that is 8 units tall ("G8;").
Adds a variable called "ART_degrees" with an array of 2 floating point values: 0.0 and 3.1415927.
Adds a variable called "EXPORTS" with an array of 2 exports of the cell "ccc:gate;1{sch}": "a" and "b[0:4]".
Adds an attribute called "z0" with the integer value 50.
It is displayed anchored at the center ("D5"), 0.5 unit tall ("G0.5;"),
written as "name=value" ("N"), is a parameter ("P"), and is offset by 1 in Y ("Y1;").
Example:
The text is anchored on the left ("D4") and is 8 units tall ("G8;").
When multiple groups are declared, they appear sorted by the group name (which is derived from the cell names in it).
The syntax is:
Examples:
"sam;2{sch}" is the main schematic of the cell group consisting of all views and versions of cells with proto name "sam".
Places all views and versions of cells with proto names "high" and "higha" in the same group (there is no main schematic).
The top level of hierarchy (cell "high") has two instances of the cell
(the right instance is rotated 90 degrees) and an arc connecting them:
Here is the JELIB file for the above layout.
"C" Cell (of the form
"D" Double.
"E" Export (of the form
"F" Float.
"G" Long.
"H" Short.
"I" Integer.
"L" Library name.
"O" Tool name.
"P" Primitive Node prototype (of the form
"R" Arc prototype (of the form
"S" String.
"T" Technology name.
"V" Point2D (of the form <x> / <y>).
"Y" Byte (0-255).
ART_message(D5G8;)StxArray4x4B
ART_degrees()F[0.0,3.1415927]
EXPORTS()E[ccc:gate;1{sch}:a,"ccc:hate;1{sch}:b[0:4]"]
ATTR_z0(D5G0.5;NPY1;)I50
10-4-2: Text Descriptors
Text descriptors appear in every Variable, and also in other places (cell instances and exports).
It consists of these fields:
A <size> ; Text is absolute size (in points). B Text is bold. C <color> ; Text is drawn in the color index given. D0 Text is anchored at its center, limited to the size of its owner. D1 Text is anchored at its lower-left. D2 Text is anchored at its bottom. D3 Text is anchored at its lower-right. D4 Text is anchored at its left. D5 Text is anchored at its center. D6 Text is anchored at its right. D7 Text is anchored at its upper-left. D8 Text is anchored at its top. D9 Text is anchored at its upper-right. F <font> ; Text is shown in the named font. G <size> ; Text has relative size (in grid units). H Variable is inheritable (only for variables on Cells or Exports). I Text is italic. L Text is underlined. N Variable is written in the form "NAME=VALUE". OJ Text is Java code. OL Text is Lisp code. OT Text is TCL code. P Variable is a parameter. R Text is rotated 90 degrees. RR Text is rotated 180 degrees. RRR Text is rotated 270 degrees. T Text is interior (seen only when inside the cell). UR Value is in Resistance units. UC Value is in Capacitance units. UI Value is in Inductance units.
UA Value is in Current units. UV Value is in Voltage units. UD Value is in Distance units. UT Value is in Time units. X <xoff> ; Text is offset in X from object center. Y <yoff> ; Text is offset in Y from object center. D4G8;
10-4-3: Groups
After all of the cells are listed, they are organized into groups.
Each group line consists simply of a list of cells in that group.
The first cell listed is the “main schematics” of the group.
If there is no such cell, the first field is empty.
After that, the cells appear in alphabetical order.
G<cell> | <cell> | … | <cell> <cell> the name of the cells in the group.
<cell> may consists only of proto name,
because all cells with the same base name are put into the same group. Gsam;2{sch}
G|high|higha
10-4-4: Example
As an example of the JELIB format, let us assume a design with two levels of hierarchy.
The bottom level of hierarchy (cell "low") has 3 nodes, two arcs, and an export:
# header information:
Hccc|8.02
# Views:
Vlayout|lay
# Technology mocmos
Tmocmos|MoCMOSNumberOfMetalLayers()I6
# Cell high{lay}
Chigh;1{lay}|mocmos|1093555876000|1094258888640|
Ngeneric:Facet-Center|art@0||0|0|0|0||AV
Ilow;1{lay}|low@0||-14|12||E|D5G4;
Ilow;1{lay}|low@1||15|12|R|E|D5G4;
AMetal-1|net@0||3|S0|low@1||5|22|low@0||-4|22
X
# Cell low{lay}
Clow;1{lay}|mocmos|1093555232000|1094258870406|
Ngeneric:Facet-Center|art@0||0|0|0|0||AV
NMetal-1-Metal-2-Con|contact@0||-10|10|5|5||
NMetal-1-Pin|pin@0||10|10|3|3||W
NMetal-2-Pin|pin@1||-10|-10|3|3||W
AMetal-1|net@0||3|S1800|contact@0||-10|10|pin@0||10|10
AMetal-2|net@1||3|S900|contact@0||-10|10|pin@1||-10|-10
Ea|D5G2;|pin@0||I
X
# Groups:
G|high;1{lay}
G|low;1{lay}